The DANFOSS iC2-30FA1N02-09A6E20F4+ACXX 2.2kW Standard Drive is a robust, single-phase 240V variable frequency drive engineered for precise motor control in demanding industrial environments. This unit offers significant advantages through its advanced control algorithms, energy-saving capabilities, and compact design. Key technical parameters include a power rating of 2.2kW, a current rating of 9.6A, and single-phase 240V input, making it an ideal solution for a wide range of applications requiring reliable and efficient motor speed regulation. The integrated advanced features and straightforward integration position the iC2 drive as a superior choice for HVAC, pump, and fan applications seeking enhanced performance and operational efficiency.


Product Specifications


| Parameter                 | Specification                                    |

| :------------------------ | :----------------------------------------------- |

| Model Number              | iC2-30FA1N02-09A6E20F4+ACXX                      |

| Power Rating              | 2.2 kW                                           |

| Current Rating            | 9.6 A                                            |

| Input Voltage             | 1-Phase, 240V                                    |

| Output Frequency Range    | 0-500 Hz                                         |

| Overload Capacity         | 150% for 60 seconds                              |

| Control Method            | V/f Control, Vector Control                      |

| Protection Class          | IP20                                             |

| Operating Temperature     | -10°C to +50°C                                   |

| Dimensions (H x W x D)    | 252mm x 140mm x 147mm                            |


Core Features & Market Positioning


The DANFOSS iC2-30FA1N02-09A6E20F4+ACXX distinguishes itself through its sophisticated sensorless vector control, delivering exceptional torque performance even at low speeds, a critical advantage in applications with dynamic load changes. Its compact footprint and integrated heatsink design facilitate easier panel mounting and thermal management, reducing installation complexity and space requirements compared to competing drives. The drive's user-friendly interface, featuring a clear LED display and intuitive keypad, simplifies configuration and operation, lowering the barrier to entry for effective variable speed control. Market positioning is firmly rooted in providing reliable, energy-efficient motor control solutions for general-purpose applications where performance and ease of use are paramount.


Key Application Scenarios


This DANFOSS iC2 drive is exceptionally well-suited for centrifugal fan and pump applications, where its precise speed control directly translates to significant energy savings by matching motor output to system demand. It is an ideal choice for HVAC systems, controlling air handling units and circulation pumps to maintain optimal climate conditions while minimizing energy consumption. In material handling, the drive can provide smooth acceleration and deceleration for conveyor systems, reducing mechanical stress and improving product throughput. The 1-phase 240V input makes it particularly valuable for installations where only single-phase power is available, expanding its applicability across various commercial and light industrial settings.


Practical System Integration Guidance


Integrating the DANFOSS iC2-30FA1N02-09A6E20F4+ACXX is streamlined due to its standard mounting dimensions and straightforward wiring. For optimal performance and safety, ensure the input power supply is correctly connected to terminals L1 and N, and the motor is wired to terminals U, V, and W. Grounding must be properly established to the designated grounding terminal. Initial commissioning involves basic parameter setup, typically accessed via the keypad, to define motor nameplate data, desired speed ranges, and any specific control modes (e.g., V/f or sensorless vector). For advanced configurations, such as remote control or specific I/O assignments, refer to the comprehensive programming manual, but core functionality is achievable with minimal parameter adjustment.


Operation and Risk Mitigation


Operating the DANFOSS iC2-30FA1N02-09A6E20F4+ACXX involves understanding its control interface and safety features. Always ensure the drive is powered down before making any electrical connections or adjustments. The drive offers protection against common motor faults, including overload, overvoltage, undervoltage, and short circuits, indicated by specific fault codes displayed on the LED panel. For instance, fault code 'F01' typically signifies an overload condition, prompting a review of motor load and ambient temperature. 'F02' might indicate an overvoltage fault, suggesting issues with the input power supply or regenerative braking. Regular inspection of connections and environment, alongside adherence to the recommended operating temperature range, is crucial for preventing operational disruptions and ensuring longevity.


Scalability & Long-Term Value


While the iC2 series is designed as a robust, standalone solution, its value extends through Danfoss's broader ecosystem. The drive's compatibility with standard communication protocols (if optional modules are added) allows for integration into larger automation systems, facilitating remote monitoring and control. This forward-looking capability ensures that the iC2 drive can be a component within a growing industrial IoT (IIoT) framework. For applications with evolving requirements, Danfoss offers a range of VFDs with higher power ratings and more advanced features, providing a clear upgrade path without necessitating a complete change in system architecture or operator familiarity. This ensures long-term investment protection and adaptability to future industrial needs.


FAQs


What is the primary function of the DANFOSS iC2-30FA1N02-09A6E20F4+ACXX?

The drive controls the speed of AC motors. It precisely adjusts motor rotation speed based on demand.


This allows for significant energy savings in many applications. It also reduces mechanical wear.


It provides advanced motor protection features. It can also be integrated into control systems.


How do I connect a motor to the DANFOSS iC2-30FA1N02-09A6E20F4+ACXX?

Connect the motor leads to terminals U, V, and W. Ensure correct phasing for proper rotation.


Always verify motor nameplate data against drive parameters. This is crucial for optimal performance.


Refer to the wiring diagram in the manual for precise connections. Electrical safety precautions are vital.


What are the main benefits of using this DANFOSS iC2 drive?

It offers precise motor speed control. This enhances process efficiency and quality.


Energy savings are a key advantage. It adapts motor output to actual load requirements.


It provides advanced protection features. This prolongs motor and equipment lifespan.


Can the DANFOSS iC2-30FA1N02-09A6E20F4+ACXX be used with single-phase motors?

No, this drive is designed for three-phase motors. It converts single-phase input to three-phase output.


This allows single-phase power to run three-phase motors. It's common in residential and light commercial settings.


Ensure the motor is indeed a three-phase motor. Consult the motor's nameplate for confirmation.


What are common applications for the DANFOSS iC2-30FA1N02-09A6E20F4+ACXX?

It is ideal for HVAC systems. Think pumps, fans, and air handling units.


Material handling equipment benefits too. Conveyors and mixers are good examples.


General industrial machinery requiring variable speed control. This includes many process applications.


How do I set up basic parameters on the drive?

Access the parameter menu using the keypad. Navigate to motor data parameters.


Enter the motor's rated voltage and frequency. Input rated current and RPM from the motor nameplate.


Save the changes and exit the menu. Perform a test run to verify operation.


What is the meaning of fault code F01 on this drive?

F01 typically indicates an overload condition. The motor is drawing too much current.


Check the motor load and ambient temperature. Ensure they are within the drive's limits.


Verify motor nameplate data is correctly set. Reset the drive after addressing the cause.


Is this drive suitable for outdoor use?

No, this drive has an IP20 protection rating. It is designed for clean, dry indoor environments.


Exposure to moisture or dust can cause damage. Mount it in a control panel or enclosure.


Consider an appropriate enclosure if environmental conditions are harsh. This protects the drive.


What is the input voltage requirement for the DANFOSS iC2-30FA1N02-09A6E20F4+ACXX?

The drive requires a 1-phase 240V AC input supply. Ensure your power source matches this specification.


This makes it suitable for many standard electrical outlets. It simplifies installation in many locations.


Check local electrical codes for compliance. Incorrect voltage can damage the drive.


Does this drive support communication protocols like Modbus?

The base drive may not have integrated communication ports. Optional communication modules can be added.


These modules enable integration into SCADA or PLC systems. Check Danfoss for available communication options.


This allows for remote monitoring and control. It's essential for advanced automation.