The DANFOSS iC2-30FA1N01-02A4E20F4+ACXX 0.37kW 2.4A Single Phase 120V Standard VFD is a compact and efficient variable frequency drive designed for a wide range of industrial applications. Boasting a power output of 0.37 kW and a maximum current rating of 2.4 A, this single-phase 120V VFD offers precise motor control and significant energy savings. Its robust design and advanced features make it a compelling choice for OEMs and end-users seeking reliable and cost-effective motor speed regulation. The iC2 series is recognized for its user-friendly interface, straightforward commissioning, and excellent performance in demanding environments.
Product Specifications
| Parameter | Value |
| :---------------------- | :------------------------------------- |
| Model Number | iC2-30FA1N01-02A4E20F4+ACXX |
| Power Rating | 0.37 kW |
| Maximum Current | 2.4 A |
| Input Voltage | Single Phase 120V |
| Output | Variable Frequency Drive (VFD) |
| Frame Size | Standard (specific designation not provided in base query) |
| Protection Class | IP20 (typical for this product class) |
| Control Method | V/f control (standard) |
| Ambient Temperature | -10°C to +40°C (derating may apply) |
| Mounting | Wall or DIN rail |
Core Features & Market Positioning
The DANFOSS iC2-30FA1N01-02A4E20F4+ACXX distinguishes itself through its exceptional ease of use and robust performance for single-phase 120V applications. Unlike many VFDs in its class, the iC2 series emphasizes intuitive setup, reducing commissioning time and the need for specialized programming knowledge. Its compact footprint makes it ideal for applications where space is at a premium. Danfoss's reputation for quality and reliability in the automation industry further solidifies the iC2's market position as a dependable solution for various motor control challenges. The integrated EMC filter helps meet stringent electromagnetic compatibility standards, a crucial advantage in sensitive industrial environments.
Key Application Scenarios
This DANFOSS VFD is exceptionally well-suited for applications requiring precise speed control of single-phase 120V motors. Common use cases include fan and pump control, where variable speed operation leads to significant energy savings and optimized system performance. It is also widely adopted in conveyor systems, small machine tools, and other general-purpose industrial machinery where adjustable speed is beneficial. The 0.37kW power rating is ideal for smaller motors found in packaging equipment, material handling, and HVAC systems.
Practical System Integration Guidance
Integrating the DANFOSS iC2-30FA1N01-02A4E20F4+ACXX is streamlined due to its user-friendly design. For wiring, ensure the single-phase 120V input power is correctly connected to L1 and N terminals, and the motor is connected to U, V, and W. Always disconnect power before making any connections. Basic parameter setup for motor data (like nominal voltage, frequency, and current) and desired speed range is typically performed via the keypad and display. For more advanced configurations, such as PID control or external I/O setup, refer to the official Danfoss iC2 manual for detailed programming instructions. Safety interlocks and emergency stop connections should be implemented according to local electrical codes and safety standards.
Operation and Risk Mitigation
Operating the DANFOSS iC2-30FA1N01-02A4E20F4+ACXX requires adherence to standard VFD safety protocols. Always ensure the drive is properly grounded and that motor cables are shielded to prevent electrical noise. Avoid operating the VFD in environments exceeding its specified temperature range or with excessive dust and moisture, as this can lead to overheating and component failure. Common troubleshooting involves checking motor connections, verifying input power, and reviewing parameter settings. Error codes displayed on the keypad provide diagnostic information; for instance, an "Overcurrent" fault typically indicates a motor load exceeding the drive's capacity or a short circuit, requiring immediate power disconnection and inspection.
Scalability & Long-Term Value
The DANFOSS iC2 series offers good long-term value through its durability and efficiency. While the iC2 is a standard VFD, its integration into broader automation systems is possible. For advanced IIoT capabilities, integration with PLCs or dedicated communication modules (if supported by the specific product variant) can enable remote monitoring and control. This allows for data collection on energy usage and operational status, contributing to predictive maintenance strategies. Compatibility with standard industrial motor types ensures a wide range of applications can be addressed with this reliable Danfoss product.
Frequently Asked Questions
Q1: What is the power output of the DANFOSS iC2-30FA1N01-02A4E20F4+ACXX VFD?
The VFD has a rated power output of 0.37 kilowatts. This power level is suitable for smaller industrial motors.
It can drive motors that require this specific wattage efficiently. The drive is designed for optimal performance within this power range.
This specification ensures it matches motors commonly found in many light industrial applications. It's a key factor for selecting the correct drive for a motor.
Q2: What type of input power does this Danfoss VFD require?
This VFD requires a single-phase 120-volt AC input power supply. It is crucial to match this to the available power source.
Using the incorrect input voltage can damage the VFD. Always verify your power source before connecting the drive.
The single-phase 120V input makes it ideal for many smaller machine applications. It simplifies installation where higher voltages are not readily available.
Q3: Can I use this VFD with a three-phase motor?
No, this VFD is designed specifically for single-phase motors. It takes a single-phase input and outputs variable frequency to control a single-phase motor.
Connecting a three-phase motor to this drive will result in improper operation or damage. The VFD's internal circuitry is not configured for three-phase motor control.
Always ensure the motor type matches the VFD's capabilities for correct functionality. This is a critical compatibility requirement.
Q4: What is the maximum current rating for the iC2-30FA1N01-02A4E20F4+ACXX?
The maximum continuous current rating for this VFD is 2.4 amperes. This limit is important for motor selection and application design.
Exceeding this current limit can lead to VFD overload and failure. It dictates the size of the motor you can safely connect.
Always consult motor nameplates and VFD specifications to ensure they are properly matched. This prevents operational issues and damage.
Q5: What are the primary applications for this specific DANFOSS VFD?
This VFD is ideal for fan and pump speed control applications. It's also suitable for conveyors and small machine tools.
Its compact size and ease of use benefit packaging and material handling equipment. It efficiently regulates motor speed in HVAC systems too.
General-purpose motor control where variable speed is needed is a core application. It offers significant energy savings in these scenarios.
Q6: How do I perform basic setup and commissioning for this VFD?
Basic setup involves entering motor parameters like voltage and current via the keypad. Configure the desired speed range for your application.
Ensure proper wiring of power input and motor output connections. Always follow safety precautions and disconnect power before wiring.
Consult the Danfoss iC2 manual for detailed parameter explanations and step-by-step guides. This ensures correct and safe configuration.
Q7: What does the IP20 protection rating mean for this VFD?
IP20 means the VFD is protected against solid objects larger than 12.5 mm. It offers no protection against water ingress.
This rating indicates it should be installed in a clean, dry environment. Avoid dusty or wet locations to maintain drive integrity.
The VFD is typically enclosed but requires protection from environmental hazards. It is suitable for control cabinet installations.
Q8: How can this VFD contribute to energy savings?
By adjusting motor speed to match the load demand, energy consumption is reduced. Fans and pumps consume significantly less power at lower speeds.
Variable speed control avoids wasteful on/off cycling. It optimizes motor performance, leading to overall efficiency gains.
This translates to lower electricity bills and a reduced carbon footprint. Energy savings are a major benefit of VFD technology.
Q9: What are common error codes and how can I troubleshoot them?
Common errors include overcurrent, undervoltage, and overtemperature. Consult the manual for specific code meanings.
Overcurrent often suggests a motor issue or excessive load. Undervoltage points to input power problems.
Always disconnect power before investigating physical connections. Parameter checks and motor diagnostics are key troubleshooting steps.
Q10: Is this VFD compatible with IIoT or smart factory integration?
Basic integration is possible through PLC control or external communication modules. These allow for remote monitoring and data logging.
For advanced IIoT, look for specific communication options or gateway devices. This enables integration into a wider digital ecosystem.
While not a native IIoT device, its data capabilities can be leveraged for smart manufacturing. This enhances operational visibility and control.