The DANFOSS FC-051P1K5S2E20H3BXCXXX 1.5kW 6.8A VLT Micro Drive is a high-performance variable frequency drive designed for precise motor control in a wide array of industrial applications. This 1-phase 240V unit offers exceptional energy efficiency and robust functionality. Key advantages include its compact design, advanced thermal management, and user-friendly interface. Critical technical parameters include a power rating of 1.5 kW, a maximum output current of 6.8A, and an input voltage range of 1x 200-240V AC.


Product Specifications


| Parameter           | Value                                  |

| :------------------ | :------------------------------------- |

| Model Number        | FC-051P1K5S2E20H3BXCXXX                |

| Power Rating        | 1.5 kW                                 |

| Output Current      | 6.8 A                                  |

| Input Voltage       | 1 x 200-240 V AC                       |

| IP Rating           | IP20                                   |

| Control Type        | VVCplus, Advanced VVCplus, Flux Vector |

| Mounting Type       | Wall/Panel Mount                       |

| Enclosure           | Standard                               |

| Connectivity        | RS485                                  |

| Operating Temperature | -10 to +50 °C                          |

|     |                                        |


Core Features & Market Positioning


The DANFOSS FC-051P1K5S2E20H3BXCXXX VLT Micro Drive distinguishes itself with its advanced VVCplus control, ensuring superior motor performance and energy savings. Its robust thermal management system, featuring an optimized heatsink design, allows for reliable operation even in demanding environments, contributing to its longevity and market appeal. This drive is positioned as a cost-effective yet highly capable solution for applications requiring precise speed and torque control, offering a compelling alternative to more complex or specialized drives. Its integration capabilities with various communication protocols further enhance its value proposition in networked industrial settings.


Key Application Scenarios


This 1.5kW VLT Micro Drive is ideally suited for a broad spectrum of applications, including fan and pump control in HVAC systems, where precise flow and pressure regulation are paramount for energy efficiency. It is also extensively used in conveyor systems, material handling equipment, and small machine tools, providing the necessary variable speed and torque for optimal process automation. The drive's compact form factor and 240V single-phase input make it a practical choice for retrofitting older machinery or integrating into space-constrained control cabinets. Its robust construction ensures reliable performance in manufacturing plants, food processing facilities, and water treatment operations.


Practical System Integration Guidance


Integrating the DANFOSS FC-051P1K5S2E20H3BXCXXX typically involves direct wiring of the motor to the drive's output terminals (U, V, W) and connecting the single-phase 240V AC power supply to the input terminals. Proper grounding of both the motor and the drive is essential for safety and optimal performance. For communication, a standard RS485 serial connection can be established between the drive and a PLC or SCADA system. Basic programming involves setting motor parameters (e.g., nominal voltage, current, frequency, poles) and configuring start/stop commands and speed references, often achievable through the drive's local control panel or via the established serial communication link.


Operation and Risk Mitigation


Safe operation of the DANFOSS FC-051P1K5S2E20H3BXCXXX mandates adherence to electrical safety standards and proper installation procedures. Always ensure power is disconnected before making any wiring changes. Overload conditions, indicated by fault code F001, can typically be resolved by reducing the load or ensuring the motor is correctly sized for the application. Overvoltage (F005) or undervoltage (F006) faults often point to issues with the incoming power supply, requiring voltage checks. Familiarizing yourself with the drive's parameter settings, particularly motor data and acceleration/deceleration ramps, is crucial for preventing mechanical stress and ensuring smooth operation.


Scalability & Long-Term Value


The DANFOSS FC-051P1K5S2E20H3BXCXXX offers significant long-term value through its compatibility with Danfoss's broader VLT drive ecosystem and its built-in communication capabilities. While this specific unit is a micro drive, its VLT architecture allows for seamless integration into larger automation systems. The RS485 interface facilitates connectivity to industrial Ethernet networks via appropriate gateways, enabling its participation in IIoT strategies for enhanced data monitoring and predictive maintenance. This ensures that the drive can remain a valuable component as industrial processes evolve towards greater digital integration.


FAQs


What are the primary benefits of using the DANFOSS FC-051P1K5S2E20H3BXCXXX?

It provides precise motor speed control for optimized performance.

Energy efficiency is significantly enhanced, reducing operational costs.

Its compact design simplifies installation in various environments.



Can the DANFOSS FC-051P1K5S2E20H3BXCXXX be used with single-phase motors?

No, this drive is designed for three-phase asynchronous motors.

It converts single-phase input power to three-phase output for the motor.

Ensure your motor is rated for three-phase operation.



What is the typical input voltage range for this VLT Micro Drive?

The drive operates on a 1x 200-240V AC single-phase power supply.

It is important to verify the local power grid voltage matches this range.

Using incorrect input voltage can damage the drive.



How do I connect a motor to the DANFOSS FC-051P1K5S2E20H3BXCXXX?

Wire the motor's three phases (U, V, W) to the drive's output terminals.

Ensure proper grounding for both the motor and the drive.

Consult the installation manual for specific wiring diagrams.



What does the 6.8A rating on the DANFOSS FC-051P1K5S2E20H3BXCXXX signify?

This is the maximum continuous output current the drive can supply.

It dictates the maximum motor size the drive can safely control.

Ensure your motor's nominal current does not exceed this value.



Is the DANFOSS FC-051P1K5S2E20H3BXCXXX suitable for outdoor installations?

No, this unit has an IP20 enclosure rating, suitable for clean, dry indoor environments.

Outdoor use requires an appropriate enclosure or specialized industrial drive.

Protect the drive from moisture, dust, and extreme temperatures.



What is the communication protocol supported by this VLT Micro Drive?

It supports RS485 serial communication for control and monitoring.

This allows integration with PLCs and SCADA systems.

RS485 enables remote configuration and diagnostics.



How can I troubleshoot a fault code on the FC-051P1K5S2E20H3BXCXXX?

Refer to the drive's user manual for a complete list of fault codes.

Common faults like F001 (overload) may require load reduction.

Check power supply voltages for F005 (overvoltage) or F006 (undervoltage).



What is the maximum power output of the DANFOSS FC-051P1K5S2E20H3BXCXXX?

The drive has a nominal power rating of 1.5 kW.

This corresponds to approximately 2 horsepower for motor applications.

Ensure the motor's power requirement does not exceed this rating.



What are the environmental operating conditions for this drive?

It operates reliably in ambient temperatures between -10 and +50 °C.

Avoid installation in areas with excessive dust or humidity.

Proper ventilation is crucial to maintain optimal operating temperatures.