The DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX 1.5kW VLT Micro Drive is a compact, high-performance variable speed drive engineered for precise motor control in demanding industrial environments. This 3-phase, 240V unit, rated at 6.8A, offers exceptional energy efficiency and a robust feature set designed to optimize operational costs and enhance process reliability. Its advanced control algorithms and flexible configuration options make it a premier choice for a wide array of applications. Key advantages include its compact footprint, energy savings potential, and ease of integration, making the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX a leader in its class.
| Parameter | Specification |
| :---------------------------- | :------------------------------------------ |
| Model Number | FC-051P1K5T2E20H3BXCXXXSXXX |
| Power Rating | 1.5 kW |
| Rated Current | 6.8 A |
| Input Voltage | 3 Phase, 240V |
| Output Frequency | 0-500 Hz |
| Enclosure Class | IP20 |
| Control Method | V/f, Vector Control |
| Dimensions (H x W x D) | 249 x 140 x 192 mm |
| Ambient Temperature | -20°C to +50°C |
Core Features & Market Positioning
The DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX stands out in the market due to its integrated harmonic mitigation capabilities, reducing the need for external filters and simplifying installation. Its advanced thermal management system ensures reliable operation even under heavy loads and elevated ambient temperatures, a critical factor for continuous industrial processes. The VLT Micro Drive platform is renowned for its user-friendly interface and straightforward commissioning, allowing for rapid deployment. Danfoss's commitment to innovation is evident in the drive's ability to deliver precise motor control, leading to significant energy savings and extended equipment lifespan, positioning it as a highly competitive and cost-effective solution for businesses seeking operational excellence.
Key Application Scenarios
This DANFOSS VLT Micro Drive is exceptionally suited for variable torque applications such as pumps, fans, and compressors, where precise speed control directly translates to energy efficiency. It excels in HVAC systems, industrial automation, material handling, and water treatment facilities, optimizing performance and reducing wear on machinery. The FC-051P1K5T2E20H3BXCXXXSXXX's robust design makes it ideal for environments with moderate dust and humidity, common in food and beverage processing, and general manufacturing. Its versatility ensures it can be seamlessly integrated into a multitude of processes requiring adjustable speed and torque management.
Practical System Integration Guidance
Integrating the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX involves straightforward wiring of power and control circuits. Ensure the 3-phase 240V input power is correctly connected to the L1, L2, L3 terminals. For motor connections, use terminals T1, T2, T3. Grounding should be established to the earth terminal for safety. Control signal wiring for start/stop, speed reference, and feedback can be connected to the digital and analog inputs. Programming the drive can be accomplished via the local control panel or through software, allowing for parameter configuration to match application requirements, such as setting acceleration/deceleration ramps and overload protection levels.
Operation and Risk Mitigation
Safe operation of the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX mandates adherence to electrical safety standards and proper installation procedures. Always ensure the drive is de-energized before performing any wiring or maintenance. Overcurrent faults (e.g., Fault Code 001) typically indicate motor overload or incorrect parameter settings; verify motor nameplate data and load conditions. Under-voltage faults (e.g., Fault Code 002) suggest unstable input power; check the power supply. Proper ventilation is crucial to prevent overheating, which can lead to nuisance tripping or component damage. Regular inspection of connections and a clean operating environment will mitigate most operational risks.
Scalability & Long-Term Value
The VLT Micro Drive FC-051 platform offers excellent scalability, allowing for easy integration into larger automation systems. Its compatibility with common industrial fieldbus protocols (e.g., Modbus RTU) facilitates seamless communication with PLCs and SCADA systems, crucial for IIoT initiatives. The DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX is designed for longevity, with Danfoss's reputation for reliability ensuring a long operational life. Future-proofing is achieved through firmware update capabilities, allowing the drive to benefit from new features and performance enhancements, thereby maximizing long-term value and return on investment.
Frequently Asked Questions
What is the power rating of the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX?
The drive boasts a 1.5 kW power rating. This is suitable for a wide range of industrial motor applications. It delivers efficient power conversion for optimal performance.
This specification allows for efficient operation of medium-sized motors. It balances energy consumption with required output. Applications requiring this power level will benefit from its control.
The 1.5 kW rating ensures robust performance for many common industrial tasks. It's a key metric for matching the drive to specific motor requirements.
What voltage and phase configuration does the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX use?
This VLT Micro Drive operates on a 3-phase, 240V AC power supply. This is a standard voltage for many industrial settings. It ensures compatibility with existing electrical infrastructure.
The 3-phase input provides balanced power delivery to the motor. This enhances motor efficiency and reduces vibrations. It is designed for reliable operation in various industrial environments.
The 240V rating makes it suitable for regions and applications utilizing this voltage level. Always confirm local power grid specifications before installation.
Can the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX be used for pump applications?
Yes, it is highly suitable for pump applications. Its variable speed control optimizes flow and pressure. This leads to significant energy savings in pumping systems.
The drive's V/f and vector control modes ensure precise speed adjustment. This is crucial for maintaining desired performance without energy waste. It reduces mechanical stress on pumps.
Applications include water supply, wastewater, and HVAC circulation pumps. The FC-051P1K5T2E20H3BXCXXXSXXX offers efficient and reliable pump operation.
What is the rated current of the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX?
The rated current for this drive is 6.8 Amps. This is the maximum continuous current the drive can deliver. It's a critical parameter for motor selection.
This current rating is directly related to the 1.5 kW power output. It ensures the drive can safely power the connected motor. Always match motor FLA to drive specifications.
Ensuring the motor's full load amperage does not exceed 6.8A is vital. This prevents overcurrent conditions and protects the drive and motor.
Does the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX have integrated harmonic mitigation?
Yes, this VLT Micro Drive features integrated harmonic mitigation. This reduces harmonic distortion on the power supply. It often eliminates the need for external filters.
Integrated solutions simplify installation and reduce overall system cost. This feature contributes to a cleaner power grid and compliance with standards. It enhances system reliability.
This capability is a significant advantage for applications sensitive to power quality. It ensures efficient operation even in demanding electrical environments.
How is the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX commissioned?
Commissioning involves basic wiring and parameter setup. Ensure correct power and motor connections are made. Then, configure essential parameters like motor data and application type.
The user-friendly interface simplifies the process. Parameters for acceleration/deceleration, speed limits, and I/O configuration are key. Initial motor auto-tuning is recommended for optimal performance.
Follow the installation manual for detailed steps. Proper commissioning ensures safety, efficiency, and longevity of the drive and motor.
What are common fault codes for this drive?
Common faults include overcurrent (e.g., code 001) and under-voltage (e.g., code 002). Overcurrent suggests motor overload or short circuits. Under-voltage indicates power supply issues.
Other faults might relate to motor over-temperature, external faults, or communication errors. Consult the drive manual for a comprehensive list. Each code provides diagnostic information.
Troubleshooting involves checking connections, motor parameters, and power supply stability. Corrective actions depend on the specific fault code identified.
What is the enclosure rating of the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX?
The enclosure class is IP20. This rating signifies protection against solid objects larger than 12.5mm. It also offers no protection against water ingress.
This enclosure is suitable for control cabinets or clean industrial environments. It requires installation where it is protected from direct moisture or dust. Proper mounting is essential.
For harsh environments, external protection or a different enclosure class may be necessary. Always ensure the environment matches the IP rating requirements.
What are the dimensions of the DANFOSS FC-051P1K5T2E20H3BXCXXXSXXX?
The dimensions are 249mm (Height) x 140mm (Width) x 192mm (Depth). This compact size is beneficial for space-constrained installations. It allows for easy mounting in control panels.
These dimensions are critical for planning enclosure layouts. They ensure sufficient space for cooling and access for maintenance. Verify clearance requirements.
The small footprint of the FC-051P1K5T2E20H3BXCXXXSXXX is a key advantage. It simplifies retrofitting and new panel designs.
What is the maximum output frequency?
The maximum output frequency is 500 Hz. This allows for high-speed motor operation. It supports applications requiring speeds beyond standard mains frequency.
This high frequency capability is important for certain industrial processes. It enables dynamic speed control for specialized machinery. Ensure the motor is rated for such speeds.
The ability to reach 500 Hz provides flexibility in motor control. It is a key specification for advanced automation and high-performance applications.