Siemens 5SN6110-7CN Miniature Circuit Protection Breaker 1P 10A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6110-7CN
  • HS: 85362030
Availability:In Stock
$3.16
zhongpingtech

The Siemens 5SN6110-7CN Miniature Circuit Breaker (MCB) is a critical component for reliable electrical protection, offering a 1-pole configuration with a 10A current rating. This specific model excels in safeguarding circuits against overloads and short circuits, ensuring operational continuity and preventing damage to sensitive equipment. Its robust design and adherence to stringent industry standards make it a preferred choice for various residential, commercial, and light industrial applications. The inherent reliability and advanced tripping mechanisms of the 5SN6110-7CN provide peace of mind, minimizing downtime and enhancing overall electrical system safety.


Product Specifications


| Feature              | Specification                                  |

| :------------------- | :--------------------------------------------- |

| Product Type         | Miniature Circuit Breaker (MCB)                |

| Manufacturer         | Siemens                                        |

| Model Number         | 5SN6110-7CN                                    |

| Number of Poles      | 1P (Single Pole)                               |

| Rated Current (In)   | 10 A                                           |

| Tripping Curve       | C (Standard for inductive loads)               |

| Breaking Capacity (Icn) | 6 kA (IEC 60898-1)                             |

| Voltage Rating (Un)  | 230/400 V AC                                   |

| Frequency            | 50/60 Hz                                       |

| Protection Type      | Overload and Short Circuit Protection          |

| Terminal Type        | Screw Terminals                                |

| Mounting Type        | DIN Rail (35 mm)                               |

| Ambient Temperature  | -25°C to +55°C                                 |

| Degree of Protection | IP20 (enclosure), IP40 (installed)             |


Core Features & Market Positioning


The Siemens 5SN6110-7CN MCB stands out in the market due to its precision tripping characteristics, ensuring prompt and reliable disconnection under fault conditions. Its Type C tripping curve is specifically designed to handle moderate inrush currents typical of inductive loads, such as motors and transformers, without nuisance tripping. This feature, combined with a robust breaking capacity of 6 kA, positions the 5SN6110-7CN as a dependable solution for a wide range of circuit protection needs. Siemens' reputation for quality and innovation further solidifies its market standing, offering users a product backed by decades of electrical engineering expertise. The compact design and ease of installation also contribute to its appeal, reducing project timelines and labor costs.


Key Application Scenarios


The 1P 10A rating and Type C curve of the Siemens 5SN6110-7CN make it exceptionally well-suited for protecting individual circuits in residential distribution boards, such as lighting circuits or socket outlets serving appliances with moderate starting currents. In commercial settings, it is commonly deployed for branch circuit protection in offices, retail spaces, and small workshops, safeguarding lighting, small appliances, and electronic equipment. For light industrial applications, this MCB is effective for protecting control circuits, auxiliary power supplies, and smaller motor loads where precise overcurrent and short-circuit protection is paramount. Its versatility extends to protecting individual loads in modular electrical cabinets, providing localized and targeted safety.


Practical System Integration Guidance


Integrating the Siemens 5SN6110-7CN into an electrical system is straightforward due to its standard DIN rail mounting. Ensure the main power supply to the breaker is de-energized before installation. Connect the incoming line conductor to the upper terminal and the outgoing load conductor to the lower terminal. For a single-pole breaker, only one phase conductor is typically interrupted. Adhere to local wiring regulations and ensure that the wire size is appropriate for the 10A rating and terminal type. Use insulated tools when working with live circuits, though it is strongly recommended to isolate power entirely. The breaker's clear marking for line and load simplifies correct connection.


Operation and Risk Mitigation


The Siemens 5SN6110-7CN operates by continuously monitoring the current flowing through the circuit. If the current exceeds a predetermined level due to an overload for a sustained period or a sudden short circuit, an internal mechanism triggers, rapidly interrupting the flow of electricity. This prevents overheating of wiring, damage to connected equipment, and potential fire hazards. To mitigate risks, always ensure the breaker is rated correctly for the load it protects and that the wiring is appropriately sized. Regular visual inspection for any signs of damage or overheating, and testing of tripping functions (where applicable and safe to do so) are recommended practices. Never bypass or improperly modify the circuit breaker, as this compromises safety.


Scalability & Long-Term Value


The Siemens 5SN6110-7CN, like other components in the Siemens circuit protection portfolio, offers excellent compatibility within the broader Siemens ecosystem. This ensures that as electrical systems evolve or expand, this MCB can seamlessly integrate with other Siemens devices and control systems. While this is a single-pole unit, its standardization means it can be part of larger multi-pole assemblies using busbars, allowing for scalable protection across a panel. Its durable construction is designed for a long operational life, providing consistent protection over many years, thereby reducing the need for premature replacement and contributing to the long-term value of the electrical installation.


Frequently Asked Questions


What is the primary function of the Siemens 5SN6110-7CN MCB?

The Siemens 5SN6110-7CN MCB's primary role is to protect electrical circuits from damage caused by overcurrents. It achieves this by automatically interrupting the circuit when it detects excessive current due to overloads or short circuits. This action safeguards connected equipment and prevents potential hazards like fires.


This device acts as an automatic safety switch, essential for maintaining the integrity of electrical installations. Its precise tripping characteristics ensure timely disconnection, thereby minimizing downtime and repair costs associated with electrical faults. It is a fundamental component for ensuring electrical safety in various settings.


The 10A rating and single-pole design of the 5SN6110-7CN are optimized for protecting specific circuits, such as those powering lighting or smaller appliances. Its presence is crucial for meeting electrical safety codes and standards.


What are the key technical specifications for this Siemens circuit breaker?

The Siemens 5SN6110-7CN is a single-pole (1P) miniature circuit breaker with a rated current of 10 Amperes (10A). It features a Type C tripping curve, indicating its suitability for loads with moderate inrush currents, and boasts a breaking capacity of 6 kA, conforming to IEC standards.


This MCB operates at a rated voltage of 230/400 V AC and is designed for use with 50/60 Hz power systems. Its ambient temperature range is from -25°C to +55°C, and it mounts easily onto a standard 35mm DIN rail.


It provides reliable protection against both overload and short-circuit conditions. The enclosure offers IP20 protection, while the installed unit provides IP40 protection against solid objects.


How do I correctly install the Siemens 5SN6110-7CN in a distribution panel?

Installation requires securing the Siemens 5SN6110-7CN onto a standard 35mm DIN rail within the distribution panel. Ensure the main power supply feeding the panel is completely de-energized before commencing any work.


Connect the incoming live conductor to the upper terminal of the MCB and the outgoing conductor feeding the protected circuit to the lower terminal. Verify that the connected wires are properly stripped and securely fastened to prevent loose connections.


Always follow local electrical codes and regulations during installation. Use appropriate tools and personal protective equipment for electrical work to ensure safety and a reliable connection.


Can this 10A breaker be used for motor protection?

Yes, the Siemens 5SN6110-7CN, with its Type C tripping curve, is suitable for protecting smaller motors or motor control circuits that exhibit moderate inrush currents during startup. Its 10A rating must align with the motor's full load current and starting characteristics.


However, for larger motors or applications demanding more specialized motor protection features (like thermal overload relays), a dedicated motor protection circuit breaker or a combination of MCB and overload relay might be more appropriate. It's crucial to consult motor nameplate data and relevant electrical codes.


The 6 kA breaking capacity ensures it can safely interrupt fault currents. Proper sizing based on the motor's power and application is essential for effective protection and preventing nuisance tripping.


What is the significance of the 'Type C' tripping curve on this breaker?

A Type C tripping curve signifies that the Siemens 5SN6110-7CN will trip between 5 to 10 times its rated current (10A) during a fault condition. This characteristic is ideal for circuits feeding inductive loads that experience higher inrush currents upon startup.


This means the breaker can tolerate brief, high current surges, such as those generated when a motor starts or transformers are energized, without tripping. This prevents unnecessary interruptions in normal operation while still providing rapid protection against short circuits.


The Type C curve strikes a balance, offering protection against short circuits while accommodating the temporary overcurrents typical of many common electrical devices and appliances.


How does the 6 kA breaking capacity impact its use?

The 6 kA breaking capacity (Icn) of the Siemens 5SN6110-7CN indicates the maximum fault current it can safely interrupt without being damaged. This rating is critical for ensuring that the breaker can successfully clear a short circuit and disconnect the power.


For a 10A breaker, a 6 kA rating is generally sufficient for most residential and light commercial installations where the prospective fault current at the point of installation is typically below this level. It complies with common safety standards like IEC 60898-1.


Ensuring the actual prospective fault current at the installation location does not exceed the breaker's breaking capacity is a fundamental safety requirement in electrical design.


What voltage levels is the Siemens 5SN6110-7CN rated for?

The Siemens 5SN6110-7CN miniature circuit breaker is rated for a nominal operating voltage of 230/400 V AC. This dual rating signifies its suitability for use in single-phase systems (230V) and three-phase systems (400V) where it would typically be installed on one phase.


This voltage rating is standard for most low-voltage distribution systems in residential, commercial, and light industrial applications across many regions. It ensures the breaker can safely operate and protect circuits within these common voltage parameters.


It is crucial that the system voltage does not exceed the breaker's rated voltage to maintain its protective integrity and prevent electrical failure.


What are the physical dimensions and mounting requirements?

The Siemens 5SN6110-7CN MCB is designed for standard 35mm DIN rail mounting, a universal standard in electrical panels, facilitating easy and secure installation. Its single-pole width typically occupies two standard modules or approximately 36mm of panel space.


The exact physical dimensions (height, width, depth) are standardized for compatibility within Siemens' vast electrical product range and the broader market. Specific dimensions can be found in technical datasheets but generally conform to industry norms for compact installation.


Screw terminals are used for electrical connections, accommodating appropriate wire gauges for the 10A rating. This ensures robust and reliable termination points within the electrical enclosure.


Can I use this breaker in extreme temperature environments?

The Siemens 5SN6110-7CN is rated for operation within an ambient temperature range of -25°C to +55°C. This wide operating window allows for reliable performance in most typical environments encountered in residential, commercial, and many industrial settings.


Operating the breaker consistently at the extremes of its temperature range may affect its long-term lifespan or tripping characteristics slightly. For applications significantly outside this range, specialized equipment or environmental controls may be necessary.


It's important to ensure adequate ventilation around the breaker within the enclosure, especially in warmer environments, to allow heat dissipation and maintain optimal performance.


Where is the Siemens 5SN6110-7CN typically applied in a home electrical system?

In a home, the Siemens 5SN6110-7CN 1P 10A breaker is commonly used to protect individual circuits such as those dedicated to lighting fixtures throughout the house. It's also frequently applied to socket outlet circuits serving general-purpose receptacles where the connected load is typically moderate.


This breaker is ideal for circuits that don't have high inrush current demands, ensuring reliable power delivery for everyday appliances and electronic devices. Its single-pole configuration is standard for most individual branch circuits in residential panels.


Its application helps in compartmentalizing electrical faults, ensuring that if one circuit experiences an issue, it doesn't affect the entire home's power supply, thus enhancing overall safety and convenience.

Menu