Siemens 5SN6613-7CN Type D MCB for Industrial Equipment Protection 3P+N 13A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6613-7CN
  • HS: 85362030
Availability:In Stock
$15.32
zhongpingtech

The Siemens 5SN6613-7CN Type D MCB is a robust three-pole plus neutral Miniature Circuit Breaker engineered for superior protection of demanding industrial equipment. This 13A device distinguishes itself with its Type D tripping characteristic, offering enhanced immunity to inrush currents common in inductive loads such as motors and transformers, thereby preventing nuisance tripping. Its high breaking capacity ensures safe interruption of fault currents, safeguarding personnel and preventing costly equipment damage. The 5SN6613-7CN is designed for reliable operation in harsh industrial environments, providing critical circuit protection where other MCBs might falter.


Siemens 5SN6613-7CN: Technical Specifications


| Feature                | Specification                                  |

| :--------------------- | :--------------------------------------------- |

| Product Type           | Miniature Circuit Breaker (MCB)                |

| Manufacturer           | Siemens                                        |

| Model Number           | 5SN6613-7CN                                    |

| Poles                  | 3P+N (Three Pole plus Neutral)                 |

| Rated Current (In)     | 13A                                            |

| Tripping Characteristic| Type D                                         |

| Rated Voltage (Un)     | 400V AC (typical for industrial applications) |

| Breaking Capacity (Icn)| 10kA (IEC 60898-1) / 15kA (IEC 60947-2)       |

| Frequency              | 50/60 Hz                                       |

| Terminal Type          | Screw Terminals                                |

| Mounting               | DIN Rail (35mm)                                |

| Operating Temperature  | -25°C to +55°C                                 |

| Protection Class       | IP20 (device)                                  |


Core Features and Market Positioning


The Siemens 5SN6613-7CN stands out in the industrial circuit protection market due to its specialized Type D tripping curve. Unlike standard Type B or C breakers, Type D is specifically designed to handle high transient currents, making it ideal for protecting machinery with significant motor starts or transformer inrush, such as large pumps, compressors, or welding equipment. This feature significantly reduces operational downtime by preventing unnecessary circuit interruptions. Furthermore, Siemens' reputation for quality and reliability in industrial automation and electrical distribution systems positions the 5SN6613-7CN as a trusted solution for mission-critical applications. Its robust construction and adherence to stringent international standards like IEC 60898-1 and IEC 60947-2 underscore its premium market placement, offering peace of mind and long-term operational stability.


Key Application Scenarios


This Siemens 5SN6613-7CN Type D MCB is extensively deployed in heavy-duty industrial settings requiring protection for high-inrush current devices. Its primary applications include safeguarding large electric motors powering industrial machinery, such as those found in manufacturing plants, mining operations, and heavy construction equipment. It is also an excellent choice for protecting transformers, solenoids, and other inductive loads that experience significant temporary current surges upon energization. Furthermore, the 3P+N configuration is suitable for systems utilizing three-phase power distribution where a neutral conductor is also present and requires protection or switching. Facilities with demanding power quality requirements and a need to prevent nuisance tripping will find this MCB particularly beneficial for ensuring continuous operation.


Practical System Integration Guidance


Integrating the Siemens 5SN6613-7CN into an industrial electrical system is straightforward due to its standard DIN rail mounting and conventional screw terminals. For installation, ensure the main power supply is de-energized. The three live conductors and the neutral conductor should be connected to the respective terminals on the MCB, observing correct phase rotation for three-phase systems. The load connections are made to the output terminals. It is crucial to ensure that the rated current of the MCB (13A) is appropriately sized for the protected circuit's continuous load and complies with local electrical codes and equipment manufacturer recommendations. Proper torque should be applied to the terminal screws to ensure a secure connection and prevent overheating.


Operation and Risk Mitigation


Operating the Siemens 5SN6613-7CN involves understanding its Type D tripping characteristics. It will trip when the current exceeds approximately 10-20 times the rated current (13A) for an extended period, or much lower currents for longer durations, indicating a persistent fault. Common troubleshooting involves checking for short circuits or overloads in the protected equipment. If the MCB trips frequently, it may indicate a faulty appliance, an undersized breaker for the load, or a characteristic high inrush current that is pushing the limits of even a Type D breaker. Risk mitigation is primarily achieved through its inherent design: the high breaking capacity prevents dangerous arc flashes during short circuits, and the precise tripping mechanism protects equipment from damage due to overcurrents or prolonged low-level faults. Always ensure proper lockout/tagout procedures are followed before any inspection or maintenance work.


Scalability & Long-Term Value


The Siemens 5SN6613-7CN offers robust long-term value through its reliability and compatibility with established Siemens industrial control and power distribution platforms. While MCBs themselves are not typically "upgraded" in the traditional sense, their integration into larger Siemens systems, such as SIVACON or ALPHA distribution boards, ensures seamless expansion and interoperability. For facilities moving towards digitalization and IIoT, incorporating these MCBs into smart panels equipped with communication modules allows for remote monitoring of status, current, and tripping events, providing valuable data for predictive maintenance and operational efficiency analysis. This backward compatibility and potential for integration with modern control architectures ensure the 5SN6613-7CN remains a relevant component in evolving industrial environments.


Frequently Asked Questions


What is the primary advantage of a Type D MCB like the Siemens 5SN6613-7CN?

A Type D characteristic offers superior protection for high-inrush current loads, such as motors and transformers. This prevents nuisance tripping during startup phases, ensuring operational continuity for critical industrial equipment.


How does the 3P+N configuration benefit industrial applications?

The three-pole plus neutral design provides comprehensive protection for three-phase circuits that also utilize a neutral conductor. It ensures all critical conductors are simultaneously protected against overcurrents and faults.


What are the implications of the 10kA/15kA breaking capacity?

This high breaking capacity signifies the MCB's ability to safely interrupt significant fault currents without sustaining damage. It is crucial for installations where short-circuit currents can be substantial, protecting personnel and preventing catastrophic equipment failure.


Can the Siemens 5SN6613-7CN be used for standard lighting circuits?

While technically possible, using a Type D MCB for standard lighting circuits is generally not recommended. Type B or C MCBs are typically more suitable and cost-effective for such applications, as they offer appropriate protection without unnecessary sensitivity to inrush currents.


What is the correct way to install the 5SN6613-7CN MCB?

Install the MCB on a standard 35mm DIN rail. Connect the incoming live conductors to the three upper terminals and the neutral to the 'N' terminal. Wire the outgoing load conductors to the lower terminals, ensuring correct phase sequence for three-phase circuits.


How do I determine if this 13A MCB is the right choice for my equipment?

Consider the continuous current draw of your equipment; it should be less than 13A. Crucially, evaluate the startup inrush current. If it's very high or prolonged, a Type D is suitable. Consult equipment manuals and electrical codes for precise sizing.


What safety precautions should be taken when working with this MCB?

Always de-energize the circuit before installation or maintenance. Use appropriate personal protective equipment (PPE). Follow lockout/tagout procedures to prevent accidental re-energization. Ensure connections are secure and properly torqued.


Are there specific error codes associated with the Siemens 5SN6613-7CN?

MCBs like this do not typically have individual error codes. Tripping indicates an overcurrent or short circuit condition. The cause must be investigated in the protected circuit or equipment.


How does this MCB integrate with Siemens industrial automation systems?

It can be installed in Siemens distribution boards (e.g., SIVACON) and integrated into control panels. For digital integration, consider smart panels or auxiliary contacts for remote monitoring and data acquisition.


What is the typical lifespan of a Siemens 5SN6613-7CN MCB?

With proper installation and within specified operating conditions, these industrial-grade MCBs are designed for a long service life, often exceeding 15-20 years. Regular visual inspections and testing, if required by standards, can confirm operational integrity.

Menu