ABB S202M-C2 High Performance MCB 2P 2A C Curve

stars
  • Availability:In Stock
  • Brand:ABB
  • Model:S202M-C2
  • HS: 85362030
Availability:In Stock
$15.60
zhongpingtech

The ABB S200M-C2 is a high-performance Miniature Circuit Breaker (MCB) designed for reliable protection in demanding electrical installations. This 2-pole (2P) device features a 2 Ampere (2A) rating and a C-curve tripping characteristic, making it ideal for circuits with moderate inrush currents. Engineered for superior safety and operational efficiency, the S200M-C2 offers enhanced breaking capacity and robust construction, ensuring dependable circuit interruption and safeguarding equipment against overcurrents and short circuits. Key technical parameters include a rated voltage of 400V AC, a breaking capacity of 10kA, and compliance with IEC/EN 60898-1 and IEC/EN 60947-2 standards. Its compact design and modularity facilitate seamless integration into various distribution boards and control panels.


Product Specifications


| Parameter                       | Value                     |

| :------------------------------ | :------------------------ |

| Product Name                    | S200M-C2                  |

| Type                            | Miniature Circuit Breaker |

| Poles                           | 2                         |

| Rated Current (In)              | 2 A                       |

| Tripping Curve                  | C                         |

| Rated Voltage (Ue)              | 400 V AC                  |

| Breaking Capacity (Icn)         | 10 kA                     |

| Frequency                       | 50/60 Hz                  |

| Insulation Voltage (Ui)         | 500 V AC                  |

| Impulse Withstand Voltage (Uimp)| 4 kV                      |

| Mounting Type                   | DIN Rail                  |

| Ambient Temperature Operating   | -25 to +55 °C             |

| Standards                       | IEC/EN 60898-1, IEC/EN 60947-2 |


Core Features & Market Positioning


The ABB S200M-C2 distinguishes itself through its high breaking capacity of 10kA, providing robust protection against severe short-circuit events, a critical advantage in industrial settings where fault currents can be substantial. Its C-curve characteristic is specifically engineered to accommodate inductive loads that exhibit moderate inrush currents, such as motors and transformers, without nuisance tripping. This differentiates it from B-curve breakers, offering greater operational flexibility. Furthermore, the S200M-C2 is part of ABB's S200M series, known for its advanced thermal-magnetic tripping mechanism and superior contact system, ensuring longevity and reliable performance. This positions the product as a premium choice for applications demanding high reliability and protection against dynamic electrical stresses.


Key Application Scenarios


This ABB S200M-C2 MCB finds its primary utility in protecting individual circuits within industrial facilities, commercial buildings, and even sophisticated residential complexes. Its C-curve tripping characteristic makes it exceptionally well-suited for safeguarding circuits feeding small to medium-sized electric motors, transformers, solenoid coils, and lighting systems where momentary high currents are common during startup. It is frequently specified for use in main distribution boards, sub-distribution panels, and control cabinets that house inductive loads, offering essential overcurrent and short-circuit protection to prevent equipment damage and ensure system uptime. Applications requiring compliance with stringent electrical codes that mandate specific breaking capacities also benefit from the S200M-C2's 10kA rating.


Practical System Integration Guidance


Integrating the ABB S200M-C2 MCB into electrical systems is a straightforward process due to its standard DIN rail mounting capability. Ensure the power supply is de-energized before installation. Connect the incoming phase and neutral conductors to the designated terminals on the line side (typically marked with an arrow indicating current flow). Securely attach the MCB to a standard 35mm DIN rail by snapping it into place from above. For optimal performance and safety, use appropriately sized and insulated wiring, ensuring all connections are tight and comply with local electrical codes. The breaker's terminal capacity typically accommodates solid and stranded copper conductors up to a specified gauge, which should be verified against the product datasheet or markings on the device itself.


Operation and Risk Mitigation


The ABB S200M-C2 operates by continuously monitoring the current flow. If the current exceeds a predetermined level for a specific duration (defined by the C-curve characteristic), the internal thermal or magnetic tripping mechanism activates, rapidly opening the circuit contacts to interrupt power. This action prevents overheating of conductors and protects connected equipment from damage due to overloads or short circuits. Risk mitigation is inherent in its design; however, improper installation, such as loose connections or undersized wiring, can compromise its effectiveness. Always ensure the MCB is rated for the specific circuit's voltage and current requirements and that the breaking capacity is sufficient for the prospective fault current at the point of installation. Regularly inspect terminals for signs of corrosion or overheating.


Scalability & Long-Term Value


The ABB S200M-C2 MCB offers significant long-term value through its inherent compatibility with ABB's broader S200 series and other modular switchgear components. This ensures straightforward scalability and future-proofing of electrical installations. When expanding a system or upgrading protective devices, the S200M-C2 can be easily replaced or supplemented with other breakers from the same range, maintaining electrical panel uniformity and simplifying maintenance. While not directly an IIoT device, its robust and reliable operation contributes to the overall stability of systems that may be integrated with smart monitoring solutions. Its durable construction and adherence to international standards guarantee a long service life, minimizing the need for premature replacements and contributing to a lower total cost of ownership.


FAQs


What is the primary function of an ABB S200M-C2 MCB?

The ABB S200M-C2 MCB functions as an overcurrent protection device. It safeguards electrical circuits from damage caused by excessive current levels.


It achieves this by detecting overloads and short circuits. The breaker then automatically trips, interrupting the power flow.


This prevents overheating of wires and protects sensitive connected equipment. It is crucial for electrical safety and system reliability.


What does the "C" in ABB S200M-C2 C Curve signify?

The "C" in the C Curve designation refers to the tripping characteristic of the MCB. This curve dictates how quickly the breaker will trip in response to overcurrents.


Specifically, a C Curve is designed for circuits with moderate inductive or capacitive inrush currents. This includes applications like motors and transformers.


It allows for higher inrush currents for a short duration without tripping, preventing nuisance tripping while still providing protection.


What are the key advantages of using the ABB S200M-C2 MCB in industrial applications?

A key advantage is its high breaking capacity of 10kA. This ensures reliable protection against severe short circuits common in industrial environments.


The C-curve characteristic is another significant benefit. It accommodates the inrush currents of inductive loads like motors without unnecessary tripping.


Its robust construction and compliance with IEC standards ensure longevity and dependable performance, reducing downtime and maintenance costs.


Can the ABB S200M-C2 be used for both AC and DC circuits?

The ABB S200M-C2 is primarily designed and rated for AC (Alternating Current) circuits. Its specifications, such as the 400V AC rated voltage, confirm this.


Using this MCB on DC (Direct Current) circuits is generally not recommended and can be unsafe. DC circuits have different arc-quenching requirements.


Always refer to the product datasheet for specific application suitability. For DC applications, use MCBs specifically designed for DC circuits.


What is the rated current and breaking capacity of the ABB S200M-C2?

The rated current (In) for the ABB S200M-C2 is 2 Amperes (2A). This defines the maximum continuous current the breaker can carry without tripping.


Its breaking capacity (Icn) is 10 kiloamperes (10kA). This indicates the maximum fault current the MCB can safely interrupt.


This combination makes it suitable for protecting circuits with low current demand but potentially high fault levels.


How does the C Curve tripping characteristic of the S200M-C2 differ from other curves?

The C Curve allows for a higher inrush current compared to a B Curve, typically 5 to 10 times the rated current. This is ideal for inductive loads.


An A Curve trips at very low currents, suitable for sensitive electronic equipment. A D Curve is designed for very high inrush currents, such as large motors.


The S200M-C2's C Curve offers a balanced protection for common industrial loads that experience moderate startups.


What are the typical installation requirements for the ABB S200M-C2?

The S200M-C2 is designed for mounting on a standard 35mm DIN rail. This is a common standard in electrical panels and enclosures.


Ensure the circuit is de-energized before installation. Use appropriate wiring sizes that match the breaker's terminal capacity and the circuit's load.


Properly torque all connections to ensure reliable electrical contact and prevent overheating. Follow local electrical codes for safe installation practices.


What is the significance of the 10kA breaking capacity on the S200M-C2?

A 10kA breaking capacity signifies that the MCB can safely interrupt a short-circuit current of up to 10,000 Amperes. This is a substantial level of protection.


In industrial settings, short-circuit currents can be very high due to the proximity of power sources and large transformers. A high breaking capacity is crucial.


This capacity ensures that the MCB will not be damaged or fail to operate during a severe fault, maintaining safety and preventing further damage.


Where is the ABB S200M-C2 most commonly applied?

This MCB is commonly applied in industrial and commercial electrical distribution systems. It protects circuits with moderate inrush currents.


Typical applications include protecting small electric motors, transformers, and lighting circuits. It's also used in control panels and sub-distribution boards.


Its 2A rating makes it suitable for lower-power circuits within these larger systems.


What are the main safety considerations when using an ABB S200M-C2 MCB?

Always ensure the MCB is correctly rated for the voltage and current of the circuit it protects. Verify the breaking capacity is adequate for the potential fault level.


Installation must be performed by a qualified electrician, following all safety procedures and local electrical codes. Never attempt installation on a live circuit.


Regular inspection of terminals for damage or loose connections will help maintain operational safety and prevent potential hazards.

Menu