Siemens 5SY6306-7CC Industrial Miniature Circuit Breaker 3P 6A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SY6306-7CC
  • HS: 85362030
Availability:In Stock
$15.62
zhongpingtech

The Siemens 5SY6306-7CC is a robust 3-pole, 6A miniature circuit breaker (MCB) engineered for demanding industrial environments. This device offers superior protection against overcurrents and short circuits, ensuring the operational integrity and safety of electrical installations. Its key advantages lie in its high breaking capacity, reliable tripping characteristics, and compact design, making it an ideal choice for panel builders and plant engineers seeking dependable circuit protection. The 5SY6306-7CC's core features include a thermal-magnetic trip mechanism, precise current rating, and compliance with international safety standards, positioning it as a high-performance component within Siemens' comprehensive range of industrial electrical equipment.


Product Specifications


| Feature                    | Specification                                  |

| :------------------------- | :--------------------------------------------- |

| Product Type               | Miniature Circuit Breaker (MCB)                |

| Manufacturer               | Siemens                                        |

| Model Number               | 5SY6306-7CC                                    |

| Number of Poles            | 3                                              |

| Rated Current (In)         | 6 A                                            |

| Rated Voltage (Un)         | 400/415 V AC                                   |

| Breaking Capacity (Icn)    | 6 kA                                           |

| Trip Curve                 | C (typical for inductive loads)                |

| Frequency                  | 50/60 Hz                                       |

| Insulation Voltage (Ui)    | 500 V                                          |

| Impulse Withstand Voltage  | 4 kV                                           |

| Protection Class           | IP20 (finger-safe)                             |

| Terminal Type              | Screw Terminal                                 |

| Mounting Type              | DIN Rail (35mm)                                |

| Ambient Temperature Range  | -25°C to +45°C                                 |

| Compliance                 | IEC/EN 60898-1, IEC/EN 60947-2                 |


Core Features & Market Positioning


The Siemens 5SY6306-7CC distinguishes itself through its reliable thermal-magnetic tripping mechanism, offering swift and precise protection against both sustained overloads and instantaneous short circuits. Its Type C tripping characteristic is optimized for applications with moderate inrush currents, such as motors and transformers, preventing nuisance tripping while ensuring rapid fault clearance. This robust design and adherence to stringent IEC/EN standards underscore its position as a trusted component for critical industrial power distribution systems. The MCB's high breaking capacity of 6 kA provides a significant safety margin, capable of safely interrupting fault currents that could otherwise cause severe damage to connected equipment and electrical infrastructure.


Key Application Scenarios


This 3-pole, 6A Siemens MCB is ideally suited for protecting three-phase inductive loads, including small to medium-sized motors, pumps, fans, and compressors commonly found in manufacturing plants, water treatment facilities, and HVAC systems. Its application extends to the protection of control circuits, lighting distribution boards, and supplementary protection for sensitive electronic equipment within industrial control panels. The 5SY6306-7CC is a staple in general power distribution for industrial machinery where reliable, selective protection is paramount to prevent downtime and ensure operational continuity.


Practical System Integration Guidance


Integrating the Siemens 5SY6306-7CC into existing or new electrical panels is straightforward due to its standard 35mm DIN rail mounting capability. Installers should ensure that the ambient temperature remains within the specified operating range of -25°C to +45°C to guarantee optimal performance and longevity. When wiring, utilize appropriate conductor sizes suitable for a 6A rating and ensure all connections are securely fastened to the screw terminals to prevent thermal issues or intermittent contact. For three-phase applications, connect the incoming power to the line terminals and outgoing loads to the load terminals across all three poles, maintaining correct phase sequence. Always ensure that the overall circuit protection strategy is coordinated to achieve selectivity, preventing widespread outages during faults.


Operation and Risk Mitigation


The 5SY6306-7CC operates automatically, disconnecting the circuit when an overcurrent condition is detected. Risk mitigation is inherent in its design, preventing electrical fires, equipment damage, and potential harm to personnel. The MCB's robust construction and clear labeling facilitate easy identification of fault conditions. In the event of a trip, visually inspect the load for faults or short circuits before attempting to reset the breaker. Avoid forcing the handle or bypassing the tripping mechanism, as this negates the protective function and creates significant safety hazards. If repeated tripping occurs, a professional electrician should diagnose the underlying issue, which could range from an overloaded circuit to a fault within the connected equipment.


Scalability & Long-Term Value


The Siemens 5SY6306-7CC offers excellent long-term value through its compatibility with a wide range of Siemens industrial control and automation products, allowing for seamless integration into larger systems. Its inclusion in the extensive 5SY series facilitates potential future upgrades or expansions of electrical distribution systems, as many components within the series share common form factors and connection methods. While this specific model is designed for direct circuit protection, its presence in a standardized Siemens ecosystem supports future enhancements, such as integration with smart metering or advanced monitoring solutions, should the facility's needs evolve towards digitalization and the Industrial Internet of Things (IIoT).


Frequently Asked Questions (FAQs)


What is the breaking capacity of the Siemens 5SY6306-7CC MCB?

The Siemens 5SY6306-7CC boasts a breaking capacity of 6 kA. This is a crucial safety parameter, indicating the maximum fault current the breaker can safely interrupt. It ensures protection against severe short circuits.


Can this 6A MCB be used for motor protection?

Yes, the Type C tripping curve is suitable for motors with moderate inrush current. It prevents nuisance tripping during startup. For larger motors, specific motor protection devices may be more appropriate.


How is the Siemens 5SY6306-7CC installed?

Installation is via a standard 35mm DIN rail. Ensure secure connections using the screw terminals. Follow all local electrical codes and safety guidelines during installation.


What does "3P" signify for this circuit breaker?

"3P" indicates that the circuit breaker has three poles. This makes it suitable for protecting three-phase electrical circuits, commonly used for industrial machinery.


What type of loads is the 5SY6306-7CC best suited for?

It is ideal for protecting inductive loads like motors, pumps, and fans. It also protects control circuits and distribution boards. Its C-curve suits moderate inrush currents.


What is the rated voltage for this Siemens MCB?

The rated voltage (Un) for the Siemens 5SY6306-7CC is 400/415 V AC. This voltage rating is standard for many industrial three-phase power systems.


What is the significance of the "C" in the trip curve designation?

The "C" trip curve signifies a moderate inrush current tolerance. It's designed for loads like motors and transformers that draw higher current briefly upon startup.


What are the environmental operating limits for this breaker?

The operating ambient temperature range is -25°C to +45°C. Extreme temperatures can affect the thermal tripping mechanism's accuracy and performance.


Is this MCB suitable for residential or only industrial use?

While it meets IEC standards, its specifications like 3 poles and 6kA breaking capacity are tailored for industrial applications. It's primarily an industrial product.


What should be done if the 5SY6306-7CC trips frequently?

Frequent tripping indicates an issue. Check for overloaded circuits or faults in the connected equipment. Consult a qualified electrician for diagnosis and repair.