Siemens 5SY6316-8CC High Capacity Motor Protection Circuit Breaker 3P 16A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SY6316-8CC
  • HS: 85362030
Availability:In Stock
$16.66
zhongpingtech

The Siemens 5SY6316-8CC High Capacity Motor Protection Circuit Breaker is engineered for robust and reliable protection of three-phase induction motors. This 3-pole, 16A device offers superior thermal and electromagnetic trip mechanisms, ensuring precise and rapid disconnection under fault conditions, thereby safeguarding valuable motor assets and preventing costly downtime. Its key advantages lie in its high breaking capacity, precise adjustable trip settings, and robust construction, making it a preferred choice for demanding industrial environments. Essential technical parameters include a rated current of 16A, a breaking capacity of 15kA, and an adjustable thermal trip range of 11-16A, all designed to meet stringent industry standards.


Siemens 5SY6316-8CC: Product Specifications


| Feature                   | Specification                               |

| :------------------------ | :------------------------------------------ |

| Product Type              | Motor Protection Circuit Breaker            |

| Manufacturer              | Siemens                                     |

| Series                    | 5SY6                                        |

| Poles                     | 3P                                          |

| Rated Current (In)        | 16 A                                        |

| Rated Breaking Capacity (Icn) | 15 kA                                       |

| Thermal Trip Adjustment   | 11 - 16 A                                   |

| Electromagnetic Trip      | Fixed (typically 10-12 x In)                |

| Trip Curve                | Class 10 (for thermal overload)             |

| Voltage Rating (Ue)       | 400/415 V AC                                |

| Frequency                 | 50/60 Hz                                    |

| Terminal Type             | Screw Terminals                             |

| Mounting Type             | DIN Rail (35mm)                             |

| Protection Degree         | IP20 (enclosure), IP40 (front)              |

| Ambient Temperature Range | -25 °C to +55 °C                            |

| Compliance Standards      | IEC/EN 60947-2, IEC/EN 60947-4-1, UL, CSA |


Core Features & Market Positioning


The Siemens 5SY6316-8CC distinguishes itself through its class-leading thermal and magnetic trip characteristics, offering superior motor protection compared to standard miniature circuit breakers (MCBs). Its adjustable thermal overload setting (11-16A) allows for precise calibration to match specific motor full-load amperages, minimizing nuisance tripping while ensuring prompt response to sustained overcurrents. The integrated magnetic trip provides instantaneous protection against short circuits, a critical feature for preventing catastrophic motor damage. This combination of features positions the 5SY6316-8CC as a high-performance, reliable solution for demanding industrial motor control applications where equipment longevity and operational continuity are paramount. Its robust build quality and adherence to international standards like IEC/EN 60947-2 and IEC/EN 60947-4-1 underscore its professional-grade status.


Key Application Scenarios


This high-capacity motor protection circuit breaker is ideally suited for safeguarding three-phase induction motors across a wide spectrum of industrial sectors. Common applications include protection for pumps, fans, compressors, conveyors, mixers, and machine tools where reliable motor operation is essential for production processes. Industries such as manufacturing, water treatment, HVAC, material handling, and food processing frequently utilize devices like the Siemens 5SY6316-8CC to prevent costly motor failures due to overloads, phase imbalance, or short circuits. Its 15kA breaking capacity is sufficient for installations in systems with significant fault current potential, offering robust protection even in higher-power distribution networks.


Practical System Integration Guidance


Integrating the Siemens 5SY6316-8CC into an electrical control panel is straightforward due to its standard 35mm DIN rail mounting. Ensure the circuit breaker is installed in a clean, dry environment, adhering to the specified ambient temperature range of -25 °C to +55 °C. For wiring, connect the three power supply phases to the upper terminals (L1, L2, L3) and the motor supply leads to the lower terminals. It is critical to correctly adjust the thermal trip setting (dial on the front) to approximately 105-115% of the motor's full-load ampere (FLA) rating as indicated on the motor nameplate. Avoid over-tightening screw terminals to prevent damage and ensure a secure connection. Electrical diagrams for motor starters often feature this type of breaker as the primary protective device.


Operation and Risk Mitigation


Proper operation of the Siemens 5SY6316-8CC relies on accurate setting of the thermal overload trip dial and understanding its trip characteristics. The Class 10 rating indicates that the breaker will trip within approximately 10 seconds at six times the set overload current, providing adequate protection without excessive delay. Risk mitigation involves regular visual inspection for any signs of physical damage or overheating, and periodic testing of the trip mechanism (if testing equipment is available and procedures are understood). In the event of a trip, identify the cause of the overload or fault (e.g., jammed mechanism, voltage imbalance, short circuit) before resetting the breaker by lifting the handle. Never force the breaker to reset if it trips repeatedly; this indicates an underlying issue requiring professional diagnosis.


Scalability & Long-Term Value


The Siemens 5SY6316-8CC, as part of Siemens' comprehensive industrial control and automation portfolio, offers excellent scalability and long-term value. Its compatibility with other Siemens components, such as contactors and overload relays from the 3SK or 3RT series, allows for seamless integration into sophisticated motor control centers. For facilities embracing Industry 4.0 initiatives, this breaker can be incorporated into smart electrical distribution systems, often in conjunction with Siemens' SIRIUS 3RV series motor feeders or intelligent motor management systems that provide real-time monitoring and diagnostics. This ensures that protection systems can evolve with plant modernization, offering continuous operational insight and predictive maintenance capabilities.


Frequently Asked Questions (FAQs)


What is the purpose of a Siemens 5SY6316-8CC?

This breaker protects motors from electrical damage. It trips on overloads and short circuits.


It offers adjustable thermal settings for precise motor protection. This ensures operational reliability.


Its high breaking capacity handles fault currents, preventing system damage. It's a robust industrial solution.


How do I set the thermal trip for the 5SY6316-8CC?

Adjust the dial to match the motor's full-load amps. A common setting is 105-115% of FLA.


Refer to the motor nameplate for the FLA rating. Proper setting prevents nuisance trips.


Consult the Siemens manual for detailed setting guidelines. Expert advice ensures optimal protection.


Can the 5SY6316-8CC be used for single-phase motors?

This is a 3-pole breaker, primarily for three-phase motors. It ensures balanced protection.


Single-phase applications require a different breaker type. Consult product datasheets for options.


Using a 3-pole breaker on single-phase may not be appropriate. Ensure correct application for safety.


What is the breaking capacity of the Siemens 5SY6316-8CC?

It has a breaking capacity of 15 kA. This is important for fault conditions.


This capacity ensures it can safely interrupt fault currents. It protects downstream equipment.


A higher breaking capacity is vital in high-fault current environments. This breaker meets demanding standards.


How do I reset a tripped Siemens 5SY6316-8CC?

Identify and correct the overload or fault first. Then, lift the handle to reset.


Do not force the breaker if it repeatedly trips. This indicates a persistent issue.


Repeated tripping requires professional inspection and troubleshooting. Safety is paramount in such cases.


What is the difference between this and a standard MCB?

This breaker is designed specifically for motor protection. It has adjustable thermal settings.


Standard MCBs offer fixed trip settings, not optimized for motors. They lack nuanced overload control.


Motor protection breakers provide superior thermal and magnetic trip coordination. This enhances motor lifespan.


What are the typical applications for the 5SY6316-8CC?

It protects pumps, fans, and compressors in industrial settings. It's ideal for heavy-duty use.


Conveyor systems and machine tools also benefit from its protection. It ensures process continuity.


Manufacturing, water treatment, and HVAC industries frequently employ this breaker. It's a versatile solution.


Is the 5SY6316-8CC compatible with Siemens contactors?

Yes, it integrates well with Siemens contactors and starters. It's part of a cohesive system.


This compatibility ensures streamlined motor control solutions. It simplifies panel design and wiring.


Siemens offers a range of compatible accessories for enhanced functionality. Consult their product guides.


What are the dimensions of the Siemens 5SY6316-8CC?

It fits standard 35mm DIN rails for easy mounting. Its dimensions are standardized for panels.


Specific width and depth details can be found in the product datasheet. Precise measurements are crucial for panel layout.


Compact design allows for efficient use of space in electrical enclosures. It meets industry panel standards.


Where can I find the manual for the Siemens 5SY6316-8CC?

The official Siemens Industry Online Support portal is the best source. Search by product number.


Manuals provide detailed installation, operation, and troubleshooting information. Always refer to the latest version.


Downloadable PDFs ensure you have the necessary technical documentation readily available. This aids in proper setup.