SIEMENS QBM3120-1U Universal Differential Pressure Sensor $\pm 100$ Pa

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:QBM3120-1U
  • HS: 9026209020
Availability:In Stock
$315.82
zhongpingtech

The SIEMENS QBM3120-1U Universal Differential Pressure Sensor provides precise and reliable differential pressure measurement for HVAC and building automation systems, offering a measurement range of $\pm 100$ Pascals (Pa). This sensor is engineered for exceptional accuracy, boasting a linear analog output signal that directly correlates to the measured pressure difference, simplifying integration into existing control strategies. Its robust design ensures longevity and consistent performance in demanding industrial environments. Key technical parameters include a selectable pressure range, ensuring flexibility for various applications, and a high accuracy of $\pm 1.5$ Pa. The sensor operates on a standard 24 V AC/DC power supply, further enhancing its compatibility with common building management systems.


| Parameter              | Specification                |

| :--------------------- | :--------------------------- |

| Product Type           | Differential Pressure Sensor |

| Model                  | QBM3120-1U                   |

| Measuring Range        | $\pm 100$ Pa                 |

| Accuracy               | $\pm 1.5$ Pa                 |

| Output Signal          | 0-10 V AC / 4-20 mA selectable |

| Power Supply           | 24 V AC/DC                   |

| Operating Temperature  | -10 to 50 °C                 |

| IP Protection Class    | IP54                         |

| Connection Type        | Screw terminals              |


The SIEMENS QBM3120-1U distinguishes itself through its universal application capabilities and advanced sensor technology, positioning it as a high-value component for modern building automation. Its core advantage lies in its dual selectable output signals (0-10 V or 4-20 mA), offering unparalleled flexibility for integration with a wide spectrum of controllers and Building Management Systems (BMS). This adaptability eliminates the need for multiple sensor types, streamlining inventory and installation processes for system integrators. Furthermore, the sensor's robust construction and IP54 rating ensure reliable operation even in dusty or humid environments, a critical factor for long-term performance and reduced maintenance costs. Market positioning emphasizes its role as a precise, cost-effective solution for critical air pressure monitoring.


Key application scenarios for the SIEMENS QBM3120-1U Universal Differential Pressure Sensor are predominantly within HVAC systems and intelligent building management. It is expertly employed for monitoring pressure across filters in air handling units (AHUs) to detect clogging and trigger maintenance alerts, thereby optimizing airflow and energy efficiency. The sensor is also crucial for maintaining precise room pressure differentials in sensitive areas like laboratories, cleanrooms, and operating theaters, ensuring containment and environmental control. Furthermore, it facilitates the monitoring of static pressure in ductwork, enabling sophisticated airflow regulation and zone control within commercial and industrial facilities, directly addressing user needs for precise environmental condition management.


Practical system integration of the SIEMENS QBM3120-1U is designed for straightforward implementation. The sensor features screw terminals for secure electrical connections, compatible with standard wiring practices in industrial automation. For signal output, users can select between a voltage signal (0-10 V) or a current signal (4-20 mA) via jumper settings, allowing seamless interfacing with diverse control panels and PLCs. When integrating with a BMS, the analog output is typically wired to a corresponding analog input module. Calibration can be performed via the BMS or a local controller, ensuring accurate readings tailored to specific system requirements, minimizing commissioning time.


Operation and risk mitigation with the SIEMENS QBM3120-1U focus on maintaining accurate readings and preventing system disruptions. It is imperative to ensure the sensor is installed in a clean environment, free from excessive dust or moisture, to preserve sensor integrity, aligning with its IP54 rating. Avoid applying pressures outside the $\pm 100$ Pa range, as this could lead to sensor damage or inaccurate readings. Regular checks of the connected ductwork for leaks are recommended to ensure the differential pressure measurements accurately reflect system conditions and not external influences. Faulty readings could indicate a blocked port, a wiring issue, or a system imbalance requiring immediate investigation.


Scalability and long-term value are inherent in the design of the SIEMENS QBM3120-1U. Its compatibility with a wide array of BMS platforms and its selectable output signals make it an adaptable component for both new installations and retrofits. As buildings evolve and IIoT integration becomes more prevalent, the QBM3120-1U can seamlessly feed its accurate pressure data into digital platforms for advanced analytics, predictive maintenance, and energy optimization strategies. This ensures that the investment in this sensor contributes to a future-ready, intelligent building infrastructure, providing sustained operational benefits and supporting digital transformation initiatives within facility management.


Frequently Asked Questions:


What is the primary function of the SIEMENS QBM3120-1U?

This sensor measures the difference in air pressure between two points. It is essential for monitoring airflow and ensuring proper ventilation in buildings.


It helps detect issues like clogged filters or leaks in ductwork. This allows for proactive maintenance and optimized system performance.


The QBM3120-1U provides crucial data for HVAC control and building automation systems. It ensures comfort and safety in various environments.


What are the key advantages of using this sensor?

Its high accuracy of $\pm 1.5$ Pa ensures precise measurements for critical applications. The selectable output (0-10 V / 4-20 mA) offers great integration flexibility.


The robust IP54 rating makes it suitable for challenging industrial and commercial environments. This durability reduces maintenance needs.


It offers a cost-effective solution for reliable differential pressure monitoring. This translates to better operational efficiency and value.


Can this sensor be used in cleanroom applications?

Yes, the QBM3120-1U is ideal for maintaining precise room pressure differentials. This is critical for cleanroom containment and contamination control.


It helps ensure that the air pressure in the cleanroom is always correctly managed. This supports stringent environmental standards.


The sensor's accuracy and reliability are key to maintaining the integrity of sensitive environments. It provides the necessary data for control systems.


What is the power requirement for the QBM3120-1U?

The sensor operates on a standard 24 V AC or 24 V DC power supply. This wide compatibility simplifies integration with existing power infrastructure.


This common voltage requirement reduces the need for specialized power converters. It makes installation more straightforward and cost-effective.


Ensuring the correct voltage is supplied is crucial for the sensor's optimal performance and longevity. Always refer to installation guidelines.


How do I select the output signal (0-10 V or 4-20 mA)?

The output signal selection is typically done using jumper settings on the sensor's circuit board. Consult the product manual for exact placement.


This jumper configuration allows the sensor to interface with a wide range of control systems and PLCs. It offers adaptability for different BMS.


Correctly setting the jumpers ensures proper communication between the sensor and the controller. This is a key step during commissioning.


What is the typical lifespan of the SIEMENS QBM3120-1U?

With proper installation and maintenance, these sensors can offer a long operational lifespan. Siemens products are known for their reliability and durability.


Regularly checking for port blockages and ensuring a stable environment prolongs the sensor's functional life. Avoiding over-pressure is also critical.


The robust design and quality components contribute to sustained performance over many years of service. This ensures a good return on investment.


How is the QBM3120-1U installed in an HVAC system?

Installation involves mounting the sensor and connecting its pressure ports to the desired measurement points using tubing. Secure electrical connections are made to the terminal block.


The sensor should be mounted in a location protected from direct environmental extremes. Ensure tubing is routed without kinks to avoid affecting readings.


Proper installation is crucial for accurate differential pressure readings and the overall effectiveness of the HVAC control strategy. Follow manufacturer guidelines closely.


What are common troubleshooting issues with differential pressure sensors?

Common issues include blocked pressure ports, leaks in the connecting tubing, or incorrect wiring. These can lead to inaccurate or no readings.


The sensor itself might be faulty, or the connected control system might be misconfigured. Environmental factors like extreme temperatures can also play a role.


Always verify power supply, output signal wiring, and the integrity of the physical installation before suspecting sensor failure. Systematic diagnosis is key.


Can this sensor be integrated with IoT platforms?

Yes, by connecting the sensor's analog output to a compatible data logger or gateway, its data can be transmitted to IoT platforms. This enables remote monitoring and analysis.


The data can be used for advanced analytics, predictive maintenance, and smart building management. It supports the digital transformation of facilities.


This integration unlocks further value by leveraging pressure data for broader operational insights and efficiency gains. It is a step towards a connected building.


What is the accuracy specification of the $\pm 100$ Pa range?

The SIEMENS QBM3120-1U offers an accuracy of $\pm 1.5$ Pa within its $\pm 100$ Pa measurement range. This is a high level of precision for HVAC applications.


This accuracy ensures that critical pressure differentials are reliably detected and controlled. It is essential for sensitive environments like cleanrooms.


The precise measurement capability allows for fine-tuning of airflows and maintaining desired environmental conditions. This contributes to operational excellence.

Menu