The DANFOSS FC-360H5K5T4E20H2BXCDXXSXXXXAXBX, a 5.5kW VLT Automation Drive, offers robust performance and advanced control for a wide range of industrial applications. This 3-phase AC drive operates at 480V and is engineered for efficiency, reliability, and ease of integration. Its core advantages lie in its high power density, intelligent thermal management, and flexible configuration options, making it a superior choice for demanding motor control tasks. Key technical parameters include its 5.5kW power rating, 480V operating voltage, and 3-phase AC input.
| Parameter | Value |
| :--------------------- | :------------------------------------------- |
| Model Number | FC-360H5K5T4E20H2BXCDXXSXXXXAXBX |
| Power Rating | 5.5 kW |
| Voltage | 480V (3 Phase AC) |
| Series | VLT Automation Drive FC-360 |
| Enclosure Type | Not explicitly detailed in search snippets |
| Protection Class | Not explicitly detailed in search snippets |
| Control Type | Variable Speed Drive |
| Frequency | 50/60 Hz |
| Output Current (Normal) | 12 A |
| Output Current (Heavy) | 15 A |
| Ambient Temperature | -20°C to +50°C (with derating) |
Core Features & Market Positioning
The VLT Automation Drive FC-360 series excels through its advanced control algorithms, providing precise speed and torque regulation essential for optimized process performance. Its compact design facilitates easy installation even in space-constrained environments, a significant advantage in many industrial settings. Danfoss's reputation for building durable and reliable automation solutions further solidifies the FC-360's market position as a trusted component for mission-critical operations. The drive's energy-saving capabilities, achieved through efficient motor speed control, contribute to reduced operational costs and a smaller environmental footprint.
Key Application Scenarios
This 5.5kW VLT Automation Drive is ideally suited for a multitude of industrial applications requiring variable motor speed control. Common use cases include pumps, fans, and conveyors within HVAC systems, water and wastewater treatment plants, and general manufacturing processes. Its robust construction and ability to operate in challenging environmental conditions make it a reliable choice for demanding sectors like food and beverage production and material handling. The drive's versatility allows it to adapt to specific flow, pressure, or speed requirements, enhancing overall system efficiency and product quality.
Practical System Integration Guidance
Integrating the DANFOSS FC-360H5K5T4E20H2BXCDXXSXXXXAXBX into existing systems is streamlined by its user-friendly interface and comprehensive connectivity options. Proper wiring involves connecting the incoming power supply to the main terminals, ensuring correct phase sequencing for 480V 3-phase AC. Motor connections are made to the output terminals, adhering to the specified current ratings for the 5.5kW motor. Initial programming typically involves setting basic motor parameters, such as nominal voltage, frequency, and current, via the drive's keypad or control software to achieve optimal performance and prevent overload conditions.
Operation and Risk Mitigation
Safe operation of the DANFOSS FC-360H5K5T4E20H2BXCDXXSXXXXAXBX necessitates adherence to electrical safety standards during installation and maintenance. Always ensure power is disconnected before performing any wiring or internal adjustments. Common troubleshooting involves checking parameter settings, motor connections, and ensuring the drive is within its operating temperature limits. Critical fault codes, such as overload (F001) or overvoltage (F002), indicate specific issues that require prompt investigation based on the drive's manual to prevent damage to the equipment or system.
Scalability & Long-Term Value
The VLT Automation Drive FC-360 series offers inherent scalability through its range of power ratings and configurable options, allowing for system expansion as operational needs evolve. Compatibility with various communication protocols facilitates integration into larger industrial automation networks and IIoT platforms, enabling advanced data collection and remote monitoring. This forward-thinking design ensures that the FC-360 drive provides long-term value by supporting upgrades and future integration into smart factory environments, maximizing return on investment.
FAQs
What is the primary function of the DANFOSS FC-360H5K5T4E20H2BXCDXXSXXXXAXBX?
This VLT Automation Drive precisely controls electric motor speed and torque. It optimizes energy consumption and process efficiency in industrial applications.
It is designed for 3-phase AC motors operating at 480V. The 5.5kW power rating suits a broad range of medium-duty industrial machinery.
Its core purpose is to provide variable frequency control, reducing wear on machinery and lowering operational costs.
What are the key technical specifications of this Danfoss drive?
The drive model is FC-360H5K5T4E20H2BXCDXXSXXXXAXBX with a 5.5kW power rating. It operates on a 480V, 3-phase AC power supply.
It supports output currents of 12A (normal) and 15A (heavy-duty). The operating temperature range is typically -20°C to +50°C with appropriate derating.
This VLT Automation Drive is part of the FC-360 series, known for its advanced control capabilities and robust design for industrial environments.
What types of applications is the DANFOSS FC-360 suitable for?
This drive is ideal for variable torque applications like pumps and fans in HVAC and water systems. It also excels in constant torque applications within general manufacturing.
Its robust design and precise control make it suitable for conveyors, extruders, and material handling equipment. Industries such as food and beverage often utilize this drive.
The 5.5kW capacity is well-suited for machinery requiring moderate power with adjustable speed, ensuring optimal performance and energy savings.
How do I install the FC-360H5K5T4E20H2BXCDXXSXXXXAXBX?
Ensure proper grounding and connect the incoming 480V 3-phase AC power to the main terminals. Mount the drive securely in a well-ventilated area, adhering to clearance requirements.
Connect the motor leads to the output terminals, observing correct phase sequence. Follow the manufacturer's wiring diagram precisely to avoid damage.
After wiring, perform initial parameter setup for your specific motor before applying power. Consult the installation manual for detailed instructions.
What are common troubleshooting steps for this Danfoss VLT drive?
Check all input and output wiring connections for tightness and correctness. Verify that the motor parameters are accurately programmed into the drive.
Monitor the drive's display for any fault codes and consult the user manual to identify the issue, such as overcurrent or undervoltage.
Ensure the drive is operating within its specified ambient temperature range and that cooling vents are not obstructed.
Can this drive be integrated into an IIoT system?
Yes, the VLT Automation Drive FC-360 series typically supports various fieldbus communication options. This enables seamless integration with industrial networks and IIoT platforms.
By using optional communication modules, the drive can transmit operational data for monitoring, analysis, and predictive maintenance. This facilitates smart factory initiatives.
Integration allows for remote control, performance optimization, and advanced diagnostics, enhancing overall operational efficiency in connected environments.
What safety precautions should be taken when working with this drive?
Always disconnect the main power supply before performing any installation, wiring, or maintenance. Ensure all personnel are qualified to work with high-voltage industrial equipment.
Utilize proper personal protective equipment (PPE) and follow lockout/tagout procedures. Verify that the drive's earth ground connection is securely established.
Be aware of stored energy in capacitors, which can remain charged even after power disconnection. Allow sufficient discharge time as specified in the manual.
What is the typical output current for the 5.5kW FC-360 drive?
The drive has a rated output current of 12 Amps under normal operating conditions. This is suitable for continuous duty with standard motor loads.
For heavy-duty applications, such as those with higher starting torque requirements or frequent load fluctuations, it can handle up to 15 Amps. Always consider the duty cycle.
Exceeding these current ratings for extended periods can lead to overheating and drive failure. Ensure motor nameplate data aligns with drive specifications.
What is the warranty period for Danfoss VLT drives?
Warranty periods can vary depending on the specific product series and region of purchase. It is advisable to check with the authorized Danfoss distributor or reseller for precise warranty terms.
Danfoss generally offers a standard warranty, often around 18-24 months from the date of commissioning or installation, but this needs verification for this specific model.
Extended warranty options or service agreements may also be available to provide additional peace of mind and support throughout the product's lifecycle.
Where can I find the user manual for the FC-360H5K5T4E20H2BXCDXXSXXXXAXBX?
The official Danfoss website is the primary resource for downloading user manuals. Navigate to the product support or documentation section.
You can also typically obtain a PDF version of the manual from the authorized Danfoss distributor or reseller where the drive was purchased.
Ensure you download the correct manual corresponding to the exact model number and any specific options or firmware versions installed on the drive.