The DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXA0BX is a high-performance 3kW, 3-phase AC variable frequency drive designed for demanding industrial applications. This VLT Automation Drive, operating at 480V, offers exceptional control and efficiency, making it a cornerstone for modern automation systems. Its robust design and advanced features provide significant advantages, including precise speed and torque control, energy savings through optimized motor performance, and enhanced system reliability. Key technical parameters include a power rating of 3kW, a 3-phase AC input voltage of 480V, and a sophisticated control architecture that ensures smooth operation and rapid response times. The "A0BX" suffix indicates specific configuration options critical for tailored industrial integration.
Product Specifications
| Parameter | Value |
| :----------------------------- | :----------------------------------------- |
| Product Code | FC-360H3K0T4E20H2BXCDXXSXXXXA0BX |
| Power Rating | 3 kW |
| Input Voltage | 3 x 480 VAC |
| Output Voltage | 0-480 VAC |
| Frame Size | N/A (Specific to 'H' series, typically compact) |
| Enclosure | IP20 (Standard) |
| Control Method | V/Hz, Vector Control |
| Mounting | Wall/Panel Mount |
| Communication Options | Expandable (e.g., Profibus, EtherNet/IP) |
| Operating Temperature | -10°C to +50°C (Derating may apply) |
| Harmonic Distortion | Low (with integrated filters or options) |
Core Features & Market Positioning
The DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXA0BX distinguishes itself through its integrated advanced functionalities and robust construction, positioning it as a premium solution for applications demanding superior motor control and energy efficiency. Unlike many competitors, the FC 360 series offers enhanced thermal management, ensuring consistent performance even under challenging environmental conditions. Its advanced VVCplus (Variable Voltage and Frequency) control provides excellent dynamic performance and precise torque regulation, making it ideal for dynamic loads. The drive's modular design also facilitates easy customization and future upgrades, further solidifying its long-term value proposition in a competitive industrial automation landscape.
Key Application Scenarios
This robust 3kW VLT Automation Drive finds extensive application across various industrial sectors requiring precise motor speed and torque management. It is a preferred choice for pump and fan control in HVAC systems, where its efficiency translates to significant energy cost reductions. In material handling, the FC-360H3K0T4E20H2BXCDXXSXXXXA0BX excels in conveyor systems and automated guided vehicles, ensuring smooth acceleration and deceleration for delicate product transfer. Furthermore, its reliability and advanced control algorithms make it suitable for processing machinery in the food and beverage industry, as well as in machine tool applications for spindle and axis control, demanding high accuracy and responsiveness.
Practical System Integration Guidance
Integrating the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXA0BX into existing industrial systems is streamlined due to its user-friendly interface and comprehensive documentation. For optimal performance, ensure proper motor cable shielding and grounding to minimize electrical noise. Wiring should adhere to local electrical codes and the drive's manual, with clear separation of power and control wiring. Initial commissioning typically involves parameter setup, including motor data entry, ramp times, and speed references. For advanced integration, leveraging the available fieldbus options (e.g., Profibus DP, EtherNet/IP, Modbus TCP) requires configuring the corresponding communication modules and network settings within the drive's parameter menu. A common programming example involves setting up a simple start/stop and speed control using digital inputs and analog outputs.
Operation and Risk Mitigation
Safe and efficient operation of the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXA0BX is paramount. Always ensure the drive is de-energized and power is discharged before performing any wiring or maintenance. Proper ventilation is critical to prevent overheating; consult the manual for specific clearance requirements. Familiarize yourself with common fault codes, such as "Overcurrent" (F001) or "Motor Overload" (F002), and their recommended troubleshooting steps. Regularly inspect connections for signs of wear or damage. Implementing safety interlocks and emergency stop functions through the drive's programmable logic can significantly mitigate operational risks and ensure personnel safety.
Scalability & Long-Term Value
The DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXA0BX offers excellent scalability and long-term value, designed to adapt to evolving industrial demands. Its modular architecture allows for the addition of expansion cards for enhanced communication protocols or I/O capabilities, ensuring compatibility with future automation platforms and IIoT integration. The drive's firmware can be updated to incorporate new features and performance improvements, extending its operational lifespan. By providing precise motor control and energy optimization, it contributes to reduced operational costs and enhanced productivity, representing a sound investment for businesses seeking to maintain a competitive edge through advanced automation technologies.
Frequently Asked Questions
What is the maximum ambient temperature for the FC-360H3K0T4E20H2BXCDXXSXXXXA0BX?
The standard operating temperature range is typically between -10°C and +50°C. However, operation at the upper end of this range may require derating of the drive's output current. Always consult the product manual for specific derating curves to ensure optimal performance and longevity under elevated temperatures.
How do I reset a fault on the DANFOSS FC-360 drive?
Faults can usually be reset via the control panel keypad by navigating to the fault history and selecting the reset option. Alternatively, a remote reset can be configured using a digital input or through a communication bus. Persistent faults may indicate an underlying issue that requires further investigation.
Can I use this drive with a single-phase motor?
No, the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXA0BX is designed for three-phase AC motors. Using it with a single-phase motor is not recommended and can lead to motor damage and drive malfunction. Always match the motor type to the drive's input and output specifications.
What are the main benefits of using VVCplus control?
VVCplus control offers superior motor performance by providing precise speed and torque regulation. It ensures excellent dynamic response, allowing the motor to react quickly to changes in load. This technology also contributes to improved energy efficiency and extended motor lifespan by optimizing power delivery.
How do I set up a ramp-up and ramp-down time for this drive?
Ramp times are configured using specific parameters within the drive's menu. Parameters like ACC (Acceleration Time) and DEC (Deceleration Time) allow you to define how long it takes for the motor to reach its set speed or come to a stop. Consult the user manual for the exact parameter numbers and their corresponding settings.
What type of communication protocols does the FC-360 series support?
The FC-360 series supports various communication protocols through optional expansion cards. Common options include Profibus DP, DeviceNet, EtherNet/IP, and Modbus TCP. Selecting the correct expansion card allows seamless integration into your existing industrial network.
What is the typical power factor of the FC-360H3K0T4E20H2BXCDXXSXXXXA0BX?
The power factor is generally close to unity when the drive is operating at full load, especially with active filter options. This high power factor contributes to reduced reactive power demand on the grid and improved overall system efficiency.
How can I ensure proper motor cooling with this drive installed?
Ensure adequate ventilation around the drive and the motor itself. The drive generates heat during operation, and proper airflow prevents overheating. Maintain the recommended clearance distances specified in the installation manual for both the drive and the motor.
What are the basic wiring requirements for this VFD?
Basic wiring involves connecting the incoming three-phase power to the L1, L2, L3 terminals. The motor is connected to the U, V, W terminals. Control signals, such as start/stop and speed references, are connected to the low-voltage control terminals. Always follow the wiring diagrams in the manual.
What is the IP rating of this specific model?
The "BXCDXXSXXXXA0BX" designation within the product code typically implies a standard IP20 enclosure for the DANFOSS FC-360H3K0T4E20H2BXCDXXSXXXXA0BX. This rating signifies protection against solid objects greater than 12.5mm but offers no protection against water.