The DANFOSS FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX 45kW VLT AutomationDrive FC-301 is a high-performance variable frequency drive designed for demanding industrial applications. This 3-phase, 480V unit offers exceptional control and efficiency, boasting a 45kW power rating. Key advantages include its robust design, advanced motor control algorithms, and integrated safety features. Core features such as its IP20 enclosure, advanced cooling system, and flexible programming capabilities position it as a leading solution for optimizing motor performance across various industries. The FC-301 series is engineered for reliability and ease of integration, making it a preferred choice for complex automation tasks.
Product Specifications
| Parameter | Specification |
| :----------------- | :----------------------------------------------- |
| Product Name | VLT AutomationDrive FC-301 |
| Model Number | FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX |
| Power Rating | 45 kW |
| Voltage | 3 AC 480 V |
| Enclosure | IP20 |
| Input/Output | 3-phase input, 3-phase output |
| Control Type | Variable Frequency Drive (VFD) |
| Series | FC-301 High Power |
| Dimensions | (Specific dimensions not provided in search data) |
| Weight | (Specific weight not provided in search data) |
Core Features & Market Positioning
The DANFOSS FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX stands out in the industrial automation market due to its advanced motor control capabilities, which include precise torque and speed regulation for a wide range of motor types. Its intelligent design incorporates features for energy savings, actively reducing power consumption during periods of low demand. The FC-301 series is recognized for its reliability and robustness, making it suitable for harsh operating environments where downtime is critical. Danfoss's commitment to innovation is evident in the FC-301's ability to integrate seamlessly with various industrial networks and control systems, positioning it as a forward-thinking solution for modern manufacturing.
Key Application Scenarios
This 45kW VLT AutomationDrive is ideally suited for applications requiring precise motor control and high power output. Common scenarios include pump and fan control in HVAC systems, where variable speed operation leads to significant energy savings. It is also widely deployed in material handling systems, conveyor belts, and mixers within the food and beverage, manufacturing, and processing industries. The robust construction of the DANFOSS FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX ensures reliable performance in these demanding environments, contributing to increased productivity and reduced operational costs.
Practical System Integration Guidance
Integrating the DANFOSS FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX into an existing system involves careful consideration of electrical connections and control logic. Ensure the power supply is properly rated for 480V, 3-phase, and that appropriate circuit protection, such as fuses or circuit breakers, is installed. Wiring should adhere to local electrical codes and best practices, utilizing shielded motor cables to minimize electromagnetic interference. Commissioning typically involves setting fundamental parameters like motor data, nominal voltage, and nominal frequency via the drive's keypad or through a PC-based software tool. For networked applications, proper configuration of communication protocols (e.g., Modbus, Profibus) is essential for seamless integration with PLCs and SCADA systems.
Operation and Risk Mitigation
Safe operation of the DANFOSS FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX requires adherence to the manufacturer's guidelines and standard industrial safety procedures. Before performing any maintenance or adjustments, always disconnect all power sources and ensure the drive's internal capacitors have discharged. Common operational issues can often be resolved by consulting the drive's fault code list, which provides specific diagnostic information for troubleshooting. For instance, overcurrent faults might indicate motor issues or incorrect parameter settings, while overheating could point to inadequate ventilation or an overloaded motor. Proactive risk mitigation involves regular inspections of electrical connections, cooling fan operation, and environmental conditions to prevent premature failure.
Scalability & Long-Term Value
The DANFOSS FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX offers significant long-term value through its inherent scalability and compatibility. Danfoss provides a range of accessory options, including communication modules and remote control panels, allowing for system expansion and adaptation to evolving industrial demands. Its ability to support various motor control modes and communication protocols ensures it can be integrated into both legacy and modern industrial control architectures, including IIoT platforms. This flexibility minimizes the need for complete system overhauls, offering a cost-effective upgrade path and ensuring the drive remains a relevant component in smart factory environments.
FAQs
Q1: What are the primary benefits of using the DANFOSS FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX?
This drive offers significant energy savings by precisely controlling motor speed.
It provides enhanced motor protection and extended equipment lifespan.
Its advanced control algorithms ensure optimal process performance and efficiency.
Q2: Can the FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX be used with different types of motors?
Yes, it supports various motor types including asynchronous and permanent magnet motors.
Precise parameterization allows for optimal performance with each motor type.
Consult the manual for specific motor compatibility and setup guidelines.
Q3: What is the typical power factor correction of this drive?
This drive utilizes advanced control to improve power factor.
It actively manages reactive power to reduce energy costs.
Actual power factor depends on motor load and operating conditions.
Q4: How does the IP20 enclosure affect installation?
The IP20 rating means it offers protection against solid objects over 12.5mm.
It requires installation in a clean, dry environment or a suitable enclosure.
Adequate ventilation must be provided to prevent overheating.
Q5: What safety features are integrated into the FC-301?
It includes robust overcurrent and overvoltage protection.
Features like safe torque off (STO) enhance operational safety.
Emergency stop functionality is also a key safety aspect.
Q6: How do I set up basic parameters on the FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX?
Use the integrated keypad for manual parameter entry.
Software tools like Danfoss's VLT Software Suite simplify configuration.
Ensure motor data and application specifics are correctly entered.
Q7: What are common fault codes for this drive and how to address them?
Faults like overcurrent, overvoltage, and undervoltage are common.
Refer to the drive's manual for a complete list and specific error codes.
Troubleshooting often involves checking motor, wiring, and parameter settings.
Q8: Can this drive be networked with other industrial systems?
Yes, it supports common industrial fieldbus protocols.
This allows for remote monitoring, control, and integration with PLCs.
Ensure the correct communication module is installed and configured.
Q9: What are the energy-saving potentials with the FC-301?
Variable speed control significantly reduces energy consumption.
Optimized motor operation leads to lower electricity bills.
It contributes to overall sustainability goals for facilities.
Q10: Where can I find the full technical specifications and manual for this drive?
The official Danfoss website is the primary source for documentation.
Search for the specific model number FC-301P45KT4E20H2XGCXXXSXXXXAXBXCXXXXDX.