DANFOSS FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX 0.37kW VLT AutomationDrive 3AC 480V IP55

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$855.20
zhongpingtech

The Danfoss FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX 0.37kW VLT AutomationDrive is a sophisticated variable frequency drive (VFD) engineered for demanding industrial applications requiring precise motor control and energy efficiency. This 3-phase, 480V drive boasts an IP55 enclosure, ensuring robust protection against dust and water ingress, making it suitable for challenging environments. Its core advantages lie in its advanced control algorithms, comprehensive feature set, and exceptional reliability, positioning it as a premium solution for optimizing motor performance across various industries. Key technical parameters include its 0.37kW power rating, 3-phase AC input, and 480V operating voltage, all contributing to its suitability for a wide range of motor applications.


Product Specifications


| Parameter          | Specification                                  |

| :----------------- | :--------------------------------------------- |

| Product Number     | FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX          |

| Power Rating       | 0.37 kW                                        |

| Voltage            | 3 AC 480V                                      |

| Enclosure          | IP55                                           |

| Series             | VLT AutomationDrive FC-301                     |

| Control Type       | Variable Frequency Drive (VFD)                 |

| Input Frequency    | 50/60 Hz                                       |

| Output Frequency   | 0-500 Hz                                       |

| Overload Capacity  | 150% for 60s, 110% continuously                |

| Ambient Temperature| -20°C to +50°C (derating above 40°C)           |

| Dimensions (H x W x D) | Varies by enclosure size, consult manual |

| Weight             | Varies by enclosure size, consult manual     |


Core Features & Market Positioning


The Danfoss FC-301 series, including the FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX, distinguishes itself through its superior motor control capabilities, including advanced vector control for induction and permanent magnet motors. This precise control translates into significant energy savings, reduced mechanical stress on equipment, and enhanced process performance. Its modular design allows for customization with various option modules, such as communication cards and advanced I/O, enhancing its flexibility and integration potential. Danfoss's reputation for robust engineering and long-term reliability further solidifies the FC-301's market position as a high-performance, dependable VFD for critical industrial operations, differentiating it from less sophisticated alternatives.


Key Application Scenarios


The Danfoss FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX is ideally suited for a multitude of industrial applications where precise speed and torque control are paramount. Common scenarios include pump and fan control in HVAC systems, conveyor systems in manufacturing and logistics, extruders and mixers in chemical processing, and machine tools in metal fabrication. Its IP55 rating makes it particularly valuable in environments prone to dust and water splashes, such as food and beverage production, wastewater treatment plants, and outdoor installations. The 0.37kW power rating is well-suited for smaller to medium-sized motors in these varied sectors.


Practical System Integration Guidance


Integrating the Danfoss FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX into existing systems involves careful attention to wiring, grounding, and parameter configuration. Ensure compliance with local electrical codes for installation. For power connections, use appropriately sized copper conductors and ensure proper grounding of both the drive and the motor. The VLT AutomationDrive series typically utilizes a user-friendly interface for programming parameters related to motor data, control methods (V/f, flux vector, etc.), and application-specific functions. Referencing the Danfoss VLT AutomationDrive FC 301 manual is crucial for detailed wiring diagrams and programming examples tailored to your specific motor and application requirements.


Operation and Risk Mitigation


Safe operation of the Danfoss FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX mandates adherence to all safety instructions outlined in the product manual. Ensure the drive is properly grounded and that all personnel are trained on VFD operation and lockout/tagout procedures before performing any maintenance. Common operational risks include incorrect parameter settings leading to motor damage or process instability, and improper wiring causing drive failure or electrical hazards. Familiarize yourself with diagnostic indicators and fault codes displayed on the drive's interface; for instance, overload faults (often indicated by codes like "OL" or specific numeric codes) require investigation into motor load, ambient temperature, or drive derating.


Scalability & Long-Term Value


The Danfoss FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX offers significant long-term value through its inherent scalability and compatibility. Its modular design facilitates upgrades and expansions; option modules can be added to enhance communication protocols (e.g., PROFIBUS, EtherNet/IP) for seamless integration into Industrial Internet of Things (IIoT) platforms and SCADA systems. This adaptability ensures the drive can evolve with changing plant requirements and technological advancements, providing a future-proof investment. Furthermore, Danfoss's commitment to product longevity and ongoing support ensures that users can rely on the FC-301 series for sustained operational efficiency and performance over its extended service life.


FAQs


What are the primary benefits of using the Danfoss FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX?

This VFD offers substantial energy savings by precisely matching motor speed to load demands, reducing electricity consumption. It also extends equipment lifespan through smoother acceleration and deceleration, minimizing mechanical stress. The drive provides enhanced process control and efficiency, leading to improved productivity.


What technical specifications are most critical for selecting this drive?

Key specifications include the 0.37kW power rating to match your motor's capacity and the 3-phase 480V input voltage for compatibility with your power supply. The IP55 enclosure is vital for protection in dusty or wet industrial environments. Advanced control features ensure optimal motor performance.


How does the FC-301 drive contribute to operational efficiency and reliability?

Its advanced motor control algorithms ensure precise operation, reducing wear and tear on machinery. The robust construction and IP55 rating guarantee reliability even in harsh conditions. Built-in diagnostics and protection features help prevent downtime and facilitate quick issue resolution.


What types of motors can be controlled by the Danfoss FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX?

This drive is capable of controlling standard AC induction motors, as well as permanent magnet motors, leveraging advanced control modes like V/f and flux vector control. Ensure your motor's specifications are within the drive's operational limits for optimal performance. Proper motor data entry during commissioning is essential.


How can I ensure proper installation and wiring of this VFD?

Always consult the official Danfoss VLT AutomationDrive manual for detailed wiring diagrams and installation instructions. Ensure correct conductor sizing, proper grounding of the drive and motor, and adherence to all local electrical codes. Incorrect wiring can lead to drive failure or safety hazards.


What are common issues encountered during the setup or operation of the FC-301 drive?

Common issues include incorrect motor parameter configuration, leading to suboptimal performance or faults. Overload conditions may arise from excessive load on the motor or ambient temperatures exceeding drive ratings. Network communication setup can also be complex if not configured correctly.


How do I access and interpret fault codes on the FC-301 drive?

Fault codes are displayed on the drive's local control panel or keypad. The product manual provides a comprehensive list of all possible fault codes and their corresponding diagnostic information. Understanding these codes is crucial for efficient troubleshooting and minimizing downtime.


What is the recommended procedure for troubleshooting an overload fault on this drive?

First, verify the motor's nameplate data against the drive's configured parameters. Investigate the mechanical load on the motor for any binding or excessive resistance. Check the ambient temperature around the drive, as high temperatures may require derating or improved ventilation.


Can the Danfoss FC-301PK37T4Z55H2XGCXXXSXXXXAXBXCXXXXDX be integrated into advanced automation systems like IIoT platforms?

Yes, this drive supports various communication protocols through optional modules, enabling seamless integration with SCADA, PLC, and IIoT platforms. This allows for remote monitoring, control, and data acquisition, enhancing overall system intelligence and efficiency.


What is the expected lifespan and long-term value of this Danfoss VFD?

Danfoss VLT AutomationDrives are renowned for their durability and long operational lifespan, typically many years under normal operating conditions. The modular design allows for future upgrades and the integration of new technologies, ensuring sustained relevance and value.

Menu