SIEMENS VVF47.50 Two-Way Flanged Valve DN50 Standard Flow

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:VVF47.50
  • HS: 8481804090
Availability:In Stock
$340.35
zhongpingtech

The SIEMENS VVF47.50 Two-Way Flanged Valve DN50 Standard Flow stands as a robust and reliable solution for precise fluid control in demanding industrial environments. This flanged control valve is engineered for superior performance, offering exceptional accuracy and durability. Key advantages include its high flow capacity for its size, robust construction for longevity, and seamless integration into various automation systems. Technical parameters of note are its DN50 nominal size, standard flow characteristic, and flanged connection type, making it a versatile choice for a wide range of applications.


Product Specifications


| Specification           | Value                 |

| :---------------------- | :-------------------- |

| Valve Type              | Two-way control valve |

| Manufacturer            | Siemens               |

| Model                   | VVF47.50              |

| Nominal Size (DN)       | 50                    |

| Connection Type         | Flanged               |

| Flow Characteristic     | Standard              |

| Max Differential Pressure | 250 kPa (500 kPa)     |

| Max Operating Pressure  | 1600 kPa              |

| Operating Temperature   | -25…120 °C            |

| Actuator Type           | Electric, Electro-hydraulic |

| Body Material           | Cast iron GG25        |

| Seal Material           | EPDM                  |

| Kvs Value               | 63 m³/h               |


Core Features & Market Positioning


The SIEMENS VVF47.50 distinguishes itself through its standard flow characteristic, offering predictable and linear control essential for many process applications. Its robust cast iron body (GG25) and EPDM seals are designed to withstand demanding conditions, ensuring a long service life and minimizing maintenance downtime. This valve is positioned as a dependable workhorse in the HVAC, building services, and general industrial sectors where reliable flow regulation is paramount. Its compatibility with a range of Siemens actuators further solidifies its market presence as part of a comprehensive automation solution.


Key Application Scenarios


This SIEMENS VVF47.50 valve is ideally suited for controlling the flow of hot water, chilled water, and low-pressure steam in heating, ventilation, and air conditioning (HVAC) systems. It plays a critical role in maintaining precise temperature control in commercial buildings, industrial process heating, and cooling loops. Furthermore, its standard flow characteristic makes it a suitable choice for applications requiring proportional control, such as regulating the flow to heat exchangers or controlling the supply to terminal units in complex building management systems.


Practical System Integration Guidance


Integrating the SIEMENS VVF47.50 into an industrial control system typically involves selecting an appropriate Siemens actuator, such as the GLB series or similar electric or electro-hydraulic models, which mount directly onto the valve. Ensure the actuator's control signal (e.g., 0-10 V, 4-20 mA) matches the controller's output. Proper alignment and secure bolting of the flanges, using appropriate gaskets, are crucial for preventing leaks. Initial commissioning should involve verifying actuator stroke and response to control signals to ensure accurate flow regulation.


Operation and Risk Mitigation


Operating the SIEMENS VVF47.50 involves ensuring it is correctly actuated and that the fluid media is within its specified temperature and pressure limits. Risk mitigation primarily focuses on preventing over-pressurization and extreme temperatures, which could damage the valve body or seals. Regular inspection of seals for wear or leakage, and ensuring the actuator is functioning correctly, are essential preventive maintenance steps. In case of failure, always isolate the valve and depressurize the line before attempting any repair or replacement.


Scalability & Long-Term Value


The SIEMENS VVF47.50 offers significant long-term value through its compatibility with Siemens' broader automation platforms, enabling seamless integration into digitalized industrial environments and the Industrial Internet of Things (IIoT). Its robust design ensures a lengthy operational life, reducing the total cost of ownership. While the valve itself is not directly upgradeable in terms of core function, its integration into more advanced control strategies, facilitated by compatible actuators and controllers, provides a pathway for enhanced system performance and efficiency over time.


Frequently Asked Questions


What is the maximum differential pressure for the SIEMENS VVF47.50?


The valve can handle a maximum differential pressure of 250 kPa.

It also supports a higher rating of 500 kPa under specific conditions.

Always ensure your system's differential pressure does not exceed these limits.


What type of fluid can the SIEMENS VVF47.50 control?


It is designed for controlling hot water and chilled water.

Low-pressure steam applications are also within its operational capabilities.

Ensure the fluid is compatible with EPDM seals and cast iron.


How is the SIEMENS VVF47.50 actuated?


This valve requires an external actuator for operation.

Siemens offers compatible electric and electro-hydraulic actuators.

Actuator selection depends on control signal and torque requirements.


What is the nominal size and connection type of this valve?


The nominal size is DN50, indicating a 50mm internal diameter.

It features a flanged connection for secure, leak-proof installation.

Flange standards should be confirmed for proper mating.


What is the Kvs value of the SIEMENS VVF47.50?


The Kvs value is 63 m³/h.

This indicates the flow rate in cubic meters per hour at a 1 bar pressure drop.

This value is crucial for system hydraulic calculations.


What are the temperature limitations for the SIEMENS VVF47.50?


The valve can operate within a range of -25 to 120 degrees Celsius.

Exceeding these temperatures can compromise seal integrity and valve function.

Always monitor system temperatures to stay within specifications.


What is the maximum operating pressure for this Siemens valve?


The maximum operating pressure it can withstand is 1600 kPa.

This pressure rating is critical for system safety and valve longevity.

Regularly check system pressure to avoid exceeding this limit.


What material is the body of the SIEMENS VVF47.50 made from?


The valve body is constructed from cast iron GG25.

This material provides durability and resistance to corrosion in many water systems.

Ensure the fluid media is compatible with cast iron.


What is the seal material used in the SIEMENS VVF47.50?


The seals are made from EPDM (Ethylene Propylene Diene Monomer).

EPDM offers good resistance to water and moderate temperatures.

Check EPDM compatibility for specific chemical applications.


What does "Standard Flow" mean for this valve?


Standard flow implies a linear relationship between valve position and flow rate.

This characteristic is preferred for proportional control applications.

It ensures predictable adjustments to fluid throughput.