Delta VFD2A7MS43ANSAA MS300 VFD for Pump Control Frequency 3.0A 0.75kW

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:VFD2A7MS43ANSAA
  • HS: 8504409999
Availability:In Stock
$181.40
zhongpingtech

The Delta VFD2A7MS43ANSAA, part of the MS300 series, is a highly capable variable frequency drive engineered for precise pump control. This 0.75 kW (1 HP), 3-phase, 460V drive offers robust features designed to optimize performance, enhance energy efficiency, and ensure operational safety. Its compact design and advanced control capabilities make it an excellent choice for a wide array of industrial and commercial pump applications.


Product Specifications


| Feature             | Specification                                    |

| :------------------ | :----------------------------------------------- |

| Model Number        | VFD2A7MS43ANSAA                                  |

| Series              | MS300                                            |

| Power Rating        | 0.75 kW / 1 HP                                   |

| Input Voltage       | 460V (3 Phase)                                   |

| Output Frequency    | 0 - 599 Hz                                       |

| Rated Amps (ND)     | 3.0 A                                            |

| Rated Amps (HD)     | 2.7 A                                            |

| Enclosure           | IP20                                             |

| Motor Control       | IM and PM Motors (Open Loop)                     |

| PLC Capacity        | 2K steps                                         |

| Safe Torque Off     | Yes (SIL2/PLd)                                   |

| Brake Chopper       | Built-in                                         |

| Communication       | Built-in RS-485 (Modbus)                         |

| Optional Comms      | CANopen, PROFIBUS DP, DeviceNet, MODBUS TCP, EtherNet/IP, EtherCAT, PROFINET |

| Dimensions (approx) | Height: 128 mm, Width: 68 mm, Depth: 143 mm      |

| Weight (approx)     | 1.79 kg / 3 lbs                                  |


Core Features & Market Positioning


The Delta MS300 series, represented by the VFD2A7MS43ANSAA, is positioned as a high-performance, compact vector control drive that integrates advanced technology to meet diverse industrial demands. Its market advantage lies in its ability to support both Induction Motors (IM) and Permanent Magnet (PM) motors, offering significant application flexibility. A key differentiator is the inclusion of Safe Torque Off (STO) functionality, compliant with SIL2/PLd standards, which significantly enhances operational safety by preventing unexpected motor starts during maintenance. The drive's compact design, up to 40% smaller than previous models, optimizes panel space and simplifies installation. Furthermore, its built-in PLC capacity of 2K steps allows for basic programming without an external controller, streamlining system integration and reducing costs.


Key Application Scenarios


The Delta VFD2A7MS43ANSAA is ideally suited for a variety of pump control applications where precise speed regulation, energy efficiency, and reliability are paramount. Common scenarios include:

  Water and Wastewater Treatment: Controlling pump speeds to manage flow rates, optimize energy consumption in pumping stations, and ensure consistent water pressure.  HVAC Systems: Regulating pump and fan speeds in building management systems to maintain optimal temperature and air quality while minimizing energy usage.  Industrial Process Pumping: Managing fluid transfer in manufacturing processes, chemical plants, and food and beverage production, where precise flow control is critical.  Irrigation Systems: Providing efficient and reliable power for agricultural pumps, especially in solar-powered applications where converting DC to variable AC is essential.  General Pumping Applications: Its versatility makes it suitable for standalone pumps in various commercial and light industrial settings.


Practical System Integration Guidance


Integrating the Delta VFD2A7MS43ANSAA into a system involves careful attention to wiring and parameter configuration to ensure optimal performance and safety.


Wiring:

Power input terminals (R/L1, S/L2, T/L3) should be connected to the 460V, 3-phase power supply. Motor leads connect to the output terminals (U/T1, V/T2, W/T3). Proper grounding to the PE terminal is crucial for safety and noise reduction. Control terminals are available for external control signals, such as start/stop commands and speed references. The VFD also features one high-speed pulse input terminal (MI7) and one high-speed pulse output terminal (DFM), both capable of up to 33kHz. For remote operation, a removable 5-digit LED keypad is available. Wiring must be performed by qualified personnel to prevent damage and ensure safety.


Programming and Configuration:

Basic setup involves configuring parameters related to the motor's nameplate data, such as rated frequency, voltage, current, and number of poles. The VFD can be controlled locally via its keypad or externally through digital inputs, potentiometers, or communication interfaces like Modbus RS-485. For instance, parameter Group 00 (e.g., 00.20 for frequency command source, 00.21 for operation command source) dictates how the drive receives its speed and control signals. The built-in 2K-step PLC can be programmed for custom logic, enhancing standalone operation capabilities. Auto-tuning functions, such as dynamic or static tests, can further optimize performance by matching the VFD's output to the motor's characteristics.


Operation and Risk Mitigation


Safe and efficient operation of the Delta VFD2A7MS43ANSAA requires understanding its operational parameters and potential fault conditions.


Safe Operation:

The Safe Torque Off (STO) function is a critical safety feature that ensures the drive cannot generate torque when activated, preventing unexpected motor movement. This is essential for maintenance procedures. The drive operates within specific voltage and frequency ranges, and parameters for acceleration/deceleration times should be set to prevent mechanical stress. The IP20 enclosure rating indicates protection against solid objects larger than 12.5mm, but it is not protected against water ingress, so it should be installed in a suitable enclosure or environment.


Troubleshooting and Fault Codes:

The MS300 series is equipped with comprehensive protection features and fault monitoring. Common fault codes indicate issues such as:  Overcurrent/Overload: Caused by excessive load, short acceleration times, or motor malfunctions.  Overvoltage/Undervoltage: Occurs due to fluctuations in the power supply.  Motor Overheating (oH3): Indicates the motor temperature has exceeded safe limits.  Communication Errors (CE10, CE4, CE3): Suggest issues with communication between the drive and other devices.  EEPROM Errors (cF2): Point to potential hardware issues within the drive.


Referencing the MS300 fault list is crucial for diagnosing and resolving issues. For instance, Pr.06-01 (over-voltage stall prevention) and Pr.05-01 (motor rated current) are parameters that can help mitigate some overload conditions.


Scalability & Long-Term Value


The Delta VFD2A7MS43ANSAA offers significant long-term value through its scalability and integration capabilities. Its support for various communication protocols, including built-in RS-485 (Modbus) and optional cards for PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCAT, and PROFINET, ensures seamless integration into diverse industrial networks and IIoT platforms. This compatibility allows for remote monitoring, diagnostics, and control, enhancing overall system efficiency and enabling predictive maintenance strategies. The drive's ability to control multiple induction motors (up to 4) and support for PM motors provides flexibility for future application expansions or upgrades. The Delta MS300 series, with its advanced features and robust design, represents a reliable investment for modern, connected industrial environments.


Frequently Asked Questions (FAQs)


What is the primary function of the Delta VFD2A7MS43ANSAA?

This VFD's main role is to control the speed of AC motors, specifically for pump applications. It allows precise adjustment of motor speed to match varying load demands, thereby optimizing energy consumption and operational efficiency. It is designed for 0.75kW, 3-phase, 460V motors, offering significant flexibility.


What are the key advantages of using the Delta MS300 series VFD for pump control?

Key advantages include energy savings through precise speed control, extended equipment lifespan due to reduced mechanical stress, and enhanced safety with the integrated STO function. The compact design also saves valuable panel space, and the built-in PLC simplifies system integration.


How does the Delta VFD2A7MS43ANSAA support motor control flexibility?

It supports both Induction Motors (IM) and Permanent Magnet (PM) motors. This dual capability allows users to select the most suitable motor type for their specific pump application, whether it's for standard industrial use or high-efficiency permanent magnet motors.


Can the Delta VFD2A7MS43ANSAA be integrated into a larger automation system?

Yes, it offers excellent integration capabilities. It features built-in RS-485 (Modbus) and supports various optional communication cards like EtherNet/IP, PROFINET, and EtherCAT, allowing seamless connection to PLCs and SCADA systems for advanced monitoring and control.


What safety features are included in the Delta MS300 VFD?

The most critical safety feature is the Safe Torque Off (STO) function, which is certified to SIL2/PLd standards. This function effectively removes power to the motor when activated, preventing unexpected starts and ensuring worker safety during maintenance or emergencies.


How does the built-in PLC functionality benefit users?

The 2K-step PLC capacity enables basic logic control and standalone operation without needing an external PLC. This simplifies wiring, reduces system complexity, lowers costs, and speeds up installation for many common control tasks.


What are the typical applications for the VFD2A7MS43ANSAA?

This VFD is widely used in water/wastewater management, HVAC systems, industrial process pumping, and irrigation systems. Its robust design and precise control make it ideal for applications requiring reliable and efficient pump operation.


What is the significance of the dual rating design (Normal Duty/Heavy Duty)?

The dual rating allows the drive to handle different load conditions. Normal Duty (ND) provides 120% overload for 60 seconds, suitable for applications with fluctuating loads. Heavy Duty (HD) offers 150% overload for 60 seconds, providing extra capacity for demanding applications.


How can I perform basic parameter setup on the Delta MS300?

Basic setup involves configuring motor parameters from the nameplate (frequency, voltage, current, poles) and setting control sources for speed and operation. Resources like the user manual and online tutorials provide step-by-step guidance for essential parameter settings and auto-tuning.


What are common troubleshooting steps for Delta MS300 VFD faults?

Troubleshooting typically involves identifying the specific fault code displayed on the VFD. Common solutions include checking motor connections, verifying parameter settings (like overload protection or acceleration times), ensuring adequate ventilation, and inspecting for physical damage. Consulting the VFD's fault code list is essential.

Menu