DANFOSS FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX 11kW VLT HVAC Drive 3AC 480V Standard

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$1115.40
zhongpingtech

The DANFOSS FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX 11kW VLT HVAC Drive is a robust, 3-phase AC variable frequency drive designed for demanding HVAC applications. It delivers precise motor control, energy efficiency, and enhanced system reliability, making it a superior choice for optimizing building performance. Key advantages include significant energy savings through optimized motor speed, reduced mechanical stress on equipment, and advanced diagnostic capabilities for proactive maintenance. This drive is engineered with a focus on seamless integration and user-friendly operation, offering a compact footprint and simplified setup for diverse HVAC installations.


| Parameter                  | Specification                               |

| :------------------------- | :------------------------------------------ |

| Product Code           | FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX      |

| Power Rating           | 11 kW                                       |

| Input Voltage          | 3 Phase AC, 480V                            |

| Output Frequency       | 0-590 Hz                                    |

| Enclosure Type         | IP20 (standard)                             |

| Cooling Method         | Forced ventilation                          |

| Control Method         | V/f, Flux Vector Control (with optional sensor) |

| Ambient Temperature    | -10°C to +40°C (derating above 40°C)        |

| Dimensions (H x W x D) | Typically ~340 x 200 x 230 mm (varies slightly based on exact variant) |

| Weight                 | Approximately 8-10 kg (varies slightly)     |


Core Features & Market Positioning


The VLT HVAC Drive FC-101 is distinguished by its inherent energy-saving capabilities, directly translating to lower operational costs for building owners. Its advanced control algorithms ensure optimal performance across a wide range of loads, minimizing energy wastage. The drive's robust design and high reliability position it as a leading solution for critical HVAC systems where downtime is unacceptable. Danfoss's commitment to innovation is evident in features like the integrated RFI suppression, which minimizes electromagnetic interference, and the user-friendly control panel, which simplifies parameterization and monitoring. This drive is engineered to meet stringent industry standards for efficiency and performance, setting it apart from less sophisticated motor control solutions.


Key Application Scenarios


The DANFOSS FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX is ideally suited for variable speed control of fans, pumps, and compressors within commercial and industrial HVAC systems. Common applications include air handling units (AHUs) for precise temperature and airflow management, chilled water and hot water circulation pumps where flow can be modulated to match demand, and exhaust fans for ventilation control in building environments. Its ability to adapt motor speed to actual system requirements significantly reduces energy consumption and wear on mechanical components, making it a prime choice for energy-efficient building management and industrial process cooling.


Practical System Integration Guidance


Integrating the DANFOSS FC-101 VLT HVAC Drive involves careful attention to electrical connections and parameter setup. The drive requires a stable 3-phase, 480V AC power supply, and it's crucial to ensure proper grounding for safety and optimal performance. Motor wiring should adhere to standard three-phase motor connection practices. For initial setup, access the control panel to configure essential parameters such as motor nameplate data (voltage, current, frequency, RPM), desired speed control mode, and application-specific settings like minimum and maximum speed limits. Utilizing the built-in display and keypad allows for straightforward navigation through the menu structure to adjust these settings, with advanced configuration often facilitated by Danfoss's PC-based software tools for more complex system integration.


Operation and Risk Mitigation


Safe operation of the DANFOSS FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX necessitates adherence to all local electrical codes and Danfoss's installation manual. Prior to powering up, verify all wiring is secure and correct, and ensure the drive's ambient temperature is within its operating range to prevent overheating. During operation, monitor for any unusual noises or vibrations from the motor or drive, which could indicate a fault. Common error codes, such as "Overcurrent" (often indicating a short circuit or motor fault) or "Overheat" (suggesting inadequate cooling or an overloaded motor), should be addressed promptly by consulting the drive's manual for specific troubleshooting steps and reset procedures to mitigate potential damage.


Scalability & Long-Term Value


The DANFOSS FC-101 VLT HVAC Drive offers significant long-term value through its inherent energy efficiency, which reduces operating expenditures over the lifespan of the equipment. Its modular design and compatibility with a range of communication protocols, such as Modbus, BACnet, or LonWorks (depending on installed options), facilitate integration into existing building management systems (BMS) or supervisory control and data acquisition (SCADA) platforms. This connectivity supports advanced monitoring, diagnostics, and remote control capabilities, aligning with Industrial Internet of Things (IIoT) strategies and enabling predictive maintenance. While direct hardware upgrades on this specific model are limited, its robust performance and adaptability ensure it remains a valuable component in evolving smart building infrastructures.


Frequently Asked Questions


1. What is the primary function of the DANFOSS FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX?

This VLT HVAC Drive controls motor speed for fans and pumps. It optimizes energy usage and system performance. It's designed for 11kW, 3-phase, 480V AC applications.


2. How does this drive save energy in HVAC systems?

It precisely matches motor speed to the actual load demand. This avoids running motors at full speed unnecessarily. Reduced speed directly translates to lower power consumption.


3. What are the essential installation requirements for this VLT HVAC Drive?

Ensure a clean, dry environment with adequate ventilation. Mount it vertically and allow sufficient clearance around the unit. Proper grounding is critical for safety and EMC.


4. Can I use this drive with any 11kW 480V motor?

Generally, yes, as long as the motor's voltage and frequency ratings are compatible with the drive's output. Always check the motor's nameplate data and the drive's specifications.


5. What is the typical operating temperature range for the FC-101 drive?

The drive is typically rated for ambient temperatures between -10°C and +40°C. Operation above 40°C requires derating the drive's output capacity. Ensure proper cooling.


6. How do I reset a fault on the DANFOSS FC-101 VLT HVAC Drive?

Many faults can be reset via the control panel after the condition is cleared. Consult the user manual for specific fault codes and reset procedures. Some faults require a power cycle.


7. What communication protocols does the FC-101 support?

This drive can support various protocols like Modbus, BACnet, and LonWorks. Specific options depend on the installed option cards. Check the product configuration for details.


8. What is the IP rating of the standard DANFOSS FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX?

The standard enclosure for this model is IP20. This means it offers protection against solid objects larger than 12.5 mm. It is not protected against water.


9. How does Flux Vector Control differ from V/f control in this drive?

Flux Vector Control offers more precise motor speed and torque regulation. V/f control is simpler and suitable for basic fan and pump applications. Vector control is better for dynamic loads.


10. Where can I find the detailed user manual for this specific VLT HVAC Drive model?

The official Danfoss website is the primary source for all product documentation. Search for the exact product code or series to download the comprehensive user and installation manuals.

Menu