DANFOSS FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX 110kW VLT AutomationDrive FC-302 3AC 500V

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$12925.00
zhongpingtech

The Danfoss FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX 110kW VLT AutomationDrive represents a robust and versatile variable frequency drive engineered for demanding industrial applications. This 3-phase AC drive boasts a 110kW power rating and operates at 500V, offering significant energy savings and precise motor control. Its advanced design facilitates integration into complex automation systems, enhancing operational efficiency and reliability across various sectors. Key advantages include superior motor performance, reduced energy consumption, and enhanced process optimization, making it a preferred choice for modern industrial automation.


| Parameter                     | Specification                                       |

| :---------------------------- | :-------------------------------------------------- |

| Product Code              | FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX              |

| Manufacturer              | Danfoss                                             |

| Series                    | VLT AutomationDrive FC-302                          |

| Power Rating              | 110 kW                                              |

| Motor Supply Type         | 3-Phase AC                                          |

| Input Voltage             | 500V                                                |

| Enclosure Class           | IP20/IP21 (depending on configuration)              |

| Control Method            | V/f, Vector Control, Advanced MC                     |

| Harmonic Suppression      | Integrated filters (optional)                       |

| Communication Options     | Various fieldbus options (e.g., Profibus, EtherNet/IP) |

| Operating Temperature     | -20°C to +50°C (derating may apply)                  |

| Dimensions (approximate)  | Varies by enclosure size                            |

| Weight (approximate)      | Varies by enclosure size                            |


The Danfoss FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX stands out in the competitive industrial automation market due to its advanced control algorithms and robust build quality. Its ability to deliver precise motor speed and torque control, even under fluctuating load conditions, is a significant differentiator. The drive supports multiple control modes, including V/f, Vector Control, and Advanced Motor Control, allowing users to optimize performance for a wide range of motor types and applications. Furthermore, its integrated harmonic suppression capabilities (with optional filters) contribute to a cleaner power grid, reducing interference and ensuring compliance with stringent electrical standards. This focus on performance, efficiency, and compliance positions the FC-302 series as a high-value solution for industries seeking to upgrade their automation infrastructure.


This 110kW VLT AutomationDrive is exceptionally well-suited for applications requiring precise speed and torque regulation in dynamic environments. It is commonly deployed in pump and fan control, where variable speed operation leads to substantial energy savings. Conveyor systems, extruders, mixers, and general industrial machinery also benefit from the drive's precise control capabilities, ensuring consistent product quality and process stability. Its robust design and advanced features make it ideal for sectors such as water and wastewater treatment, food and beverage processing, manufacturing, and material handling, where reliability and efficiency are paramount.


System integration for the Danfoss FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX 110kW VLT AutomationDrive typically involves careful consideration of power and control wiring. Ensure the main power input is correctly connected to the designated terminals, observing proper grounding and torque specifications. Control signals, such as start/stop commands, speed references, and feedback signals, should be wired to the low-voltage control terminals, respecting the drive's internal logic and voltage levels. For advanced integration, fieldbus communication modules need to be installed and configured according to the specific network protocol. Commissioning involves parameter setup, including motor data, application-specific settings, and safety functions, often facilitated by Danfoss’ user-friendly software tools.


Safe operation and effective risk mitigation with the Danfoss FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX require adherence to electrical safety standards and proper commissioning procedures. Always ensure the drive is de-energized before performing any wiring or maintenance. Familiarize yourself with the drive's fault code system; for instance, common errors might relate to overcurrent (e.g., Fault 4), undervoltage (e.g., Fault 7), or motor overload (e.g., Fault 5). Proper parameterization, including setting correct motor thermal protection and creep speeds, helps prevent damage and ensures smooth operation, minimizing unexpected shutdowns and potential hazards.


The Danfoss FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX offers significant scalability and long-term value through its flexible architecture and compatibility. It can be integrated into existing Distributed Control Systems (DCS) or Programmable Logic Controller (PLC) setups using various fieldbus options, allowing for seamless upgrades and expansions. The drive's support for IIoT connectivity through optional modules enables real-time monitoring, predictive maintenance, and integration with cloud-based analytics platforms. This forward-looking design ensures that your investment remains relevant and contributes to the ongoing digital transformation of your industrial operations.


FAQs


What are the primary benefits of using the Danfoss FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX?

This drive offers significant energy savings by precisely controlling motor speed, reducing power consumption. It enhances process efficiency through accurate torque and speed regulation. The robust design ensures high reliability and extends equipment lifespan.


What are the core technical specifications of the FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX?

It is a 110kW, 3-phase AC drive operating at 500V. It supports V/f, Vector, and Advanced MC control. The enclosure is typically IP20/IP21 and it offers various fieldbus communication options.


How does this drive contribute to operational efficiency and safety in industrial settings?

Precise motor control optimizes production output and quality. Reduced wear on machinery leads to fewer breakdowns and maintenance costs. Integrated safety functions protect personnel and equipment.


What are the recommended applications for the Danfoss FC-302N110T5E20H2XGCXXXSXXXXAXBXCXXXXDX?

It is ideal for pump and fan applications requiring variable speed control. It is also used in conveyor systems, extruders, mixers, and general industrial machinery. Sectors like water treatment and food processing benefit greatly.


How does this drive facilitate integration into existing automation systems?

It supports various fieldbus communication protocols for easy integration with PLCs and DCS. Its flexible parameterization allows customization for specific machine requirements. Danfoss provides software tools for simplified commissioning.


What are the key considerations for wiring and installation of this drive?

Ensure correct connection of power and control wiring according to the manual. Use appropriate cable types and torque settings for secure connections. Proper grounding is essential for safety and performance.


Can this drive be used with different types of AC motors?

Yes, the FC-302 supports various AC motor types, including asynchronous and permanent magnet motors. Advanced control modes optimize performance for different motor technologies. Accurate motor data entry is crucial for optimal operation.


What troubleshooting steps can be taken for common issues with this drive?

Consult the drive's fault code list for error identification. Common issues include overcurrent, undervoltage, or motor overload faults. Check wiring, parameter settings, and motor condition if faults occur.


How does the Danfoss FC-302 series support IIoT and digital transformation initiatives?

It offers optional communication modules for IIoT connectivity. This enables remote monitoring, data logging, and integration with cloud platforms. Predictive maintenance capabilities can be leveraged through this connectivity.


What are the long-term value propositions of investing in this specific VLT AutomationDrive?

It provides substantial energy cost reductions over its operational life. Its robust construction ensures durability and minimal downtime. The drive's upgradeability and compatibility protect the investment.

Menu