Siemens 3VA1180-6MH32-0AA0 3VA11 Series Molded Case Circuit Breaker 80A 160A 3P 85kA

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3VA1180-6MH32-0AA0
  • HS: 8536200000
Availability:In Stock
$152.10
zhongpingtech

The Siemens 3VA1180-6MH32-0AA0 is a robust 3-pole molded case circuit breaker from the 3VA11 series, engineered for reliable circuit protection in demanding industrial environments. Boasting a rated current of 80A and a maximum breaking capacity of 85kA at 400/415V, this device offers exceptional performance and safety. Its high interrupting rating ensures effective fault current management, safeguarding electrical systems against damage. The 3VA11 series is renowned for its compact design, flexibility, and advanced thermal-magnetic tripping technology, making it a premier choice for power distribution and motor protection applications.


Product Specifications


| Feature                | Specification                                      |

| :--------------------- | :------------------------------------------------- |

| Product Type           | Molded Case Circuit Breaker (MCCB)                 |

| Series                 | 3VA11                                              |

| Model Number           | 3VA1180-6MH32-0AA0                                 |

| Number of Poles        | 3-pole                                             |

| Rated Current (In)     | 80 A                                               |

| Adjustable Trip Current| 80 A to 160 A (Thermal-Magnetic)                   |

| Rated Voltage (Ue)     | 600 V AC / 250 V DC                                |

| Capaciity (Icu)| 85 kas and 400/415 V AC                               4  40/415 V AC                    LC  C AC                  LC 4

| Trip Unit Type         | Thermal-Magnetic (TM)                              |

| Frequency              | 50/60 Hz                                           |

| Mounting Type          | Fixed, front or rear connection                    |

| Terminal Type          | Screw terminals                                    |

| Standards Compliance   | IEC 60947-2, UL 489, CSA C22.2 No. 5                |

| Protection Functions   | Overload, Short-circuit                            |


Core Features & Market Positioning


The Siemens 3VA1180-6MH32-0AA0 distinguishes itself through its superior breaking capacity of 85kA, providing unparalleled protection against severe short-circuit events, a critical advantage in high-power industrial settings. Its adjustable thermal-magnetic trip unit offers flexibility, allowing users to fine-tune protection settings from 80A up to 160A, catering to diverse load requirements and enhancing system adaptability. This adaptability positions the 3VA11 series as a versatile solution, reducing the need for multiple breaker types and simplifying inventory management for panel builders and system integrators. The inherent reliability and robust construction, characteristic of Siemens industrial automation products, further solidify its market position as a dependable and long-lasting component for critical infrastructure.


Key Application Scenarios


This 3-pole circuit breaker is ideally suited for main and branch circuit protection in a wide array of industrial applications. Its 85kA interrupting rating makes it a prime candidate for protecting equipment in areas with high fault current potential, such as manufacturing plants, data centers, and large commercial buildings. It serves effectively in motor control centers (MCCs) for safeguarding induction motors against overloads and short circuits, ensuring continuous operation and preventing costly downtime. Additionally, the Siemens 3VA1180-6MH32-0AA0 is frequently specified for use in power distribution panels, generator protection, and as a main breaker in complex electrical distribution systems requiring robust fault-clearing capabilities.


Practical System Integration Guidance


Integrating the Siemens 3VA1180-6MH32-0AA0 into existing or new electrical systems is streamlined by its fixed mounting design and front or rear connection options. Ensure proper torque is applied to the screw terminals to maintain secure electrical contact, adhering to the manufacturer's recommendations to prevent overheating or connection failure. For optimal performance, the breaker should be installed in an environment free from excessive dust, moisture, and corrosive substances, with adequate ventilation to dissipate heat generated during operation. Wiring should be performed by qualified electricians, following local electrical codes and standards. When configuring the adjustable trip settings, careful consideration of the protected circuit's load characteristics is paramount to prevent nuisance tripping while ensuring adequate protection.


Operation and Risk Mitigation


Operation of the Siemens 3VA1180-6MH32-0AA0 is straightforward, featuring a clear lever for manual ON/OFF switching and trip indication. The thermal-magnetic trip unit provides reliable protection against sustained overloads (thermal element) and sudden high-magnitude short circuits (magnetic element). To mitigate risks, regular visual inspections for damage and proper functioning of the trip mechanism are recommended. In the event of a trip, identify and rectify the cause of the fault (e.g., overload, short circuit) before resetting the breaker. Never force the operating mechanism. Ensure all personnel working with or around the breaker are aware of its operating procedures and safety precautions, including lockout/tagout procedures during maintenance.


Scalability & Long-Term Value


The 3VA11 series, including the 3VA1180-6MH32-0AA0, offers inherent scalability through its compatibility with a range of accessories and its modular design, facilitating future system expansions or modifications. While this specific model is a fixed version, the broader 3VA platform supports various communication modules and auxiliary switches, enabling integration into modern supervisory control and data acquisition (SCADA) systems or industrial internet of things (IIoT) platforms for enhanced monitoring and control. This forward-looking capability ensures that investments in Siemens circuit protection remain relevant and valuable as industrial facilities evolve towards digitalization and smart grid technologies, providing long-term cost-effectiveness and operational efficiency.


FAQs


Q1: What is the rated current of the Siemens 3VA1180-6MH32-0AA0?

The breaker's rated current is 80 Amperes at standard operating conditions.

It can be adjusted to a maximum of 160 Amperes using the integrated trip unit.

This adjustable feature allows for flexible protection of various load sizes.


Q2: What is the breaking capacity of this circuit breaker?

This model offers a high breaking capacity of 85 kA at 400/415V AC.

Such a rating is crucial for safely interrupting severe short-circuit currents.

It ensures protection for downstream equipment in high-fault current scenarios.


Q3: Can the Siemens 3VA1180-6MH32-0AA0 be used for motor protection?

Yes, it is suitable for motor protection applications.

Its thermal-magnetic trip unit protects against overloads and short circuits.

Proper adjustment of trip settings is vital for effective motor safeguarding.


Q4: What type of trip unit does the 3VA1180-6MH32-0AA0 feature?

It is equipped with a thermal-magnetic (TM) trip unit.

This offers both overload protection via the thermal element.

It also provides instantaneous short-circuit protection via the magnetic element.


Q5: How is this circuit breaker mounted in an electrical panel?

The 3VA1180-6MH32-0AA0 is designed for fixed mounting.

It allows for connection from the front or rear of the device.

Ensure secure mounting and proper torque on terminals for reliable operation.


Q6: What standards does the Siemens 3VA1180-6MH32-0AA0 comply with?

It complies with major international standards like IEC 60947-2.

It also meets UL 489 and CSA C22.2 No. 5 requirements.

This broad compliance ensures suitability for global applications.


Q7: Is this a 3-pole or 4-pole circuit breaker?

The product designation 3VA1180-6MH32-0AA0 clearly indicates it is a 3-pole breaker.

It is designed for single-phase or three-phase systems requiring protection across three conductors.

A 4-pole version would have a different product code.


Q8: What is the significance of the 85kA breaking capacity?

85 kA represents the maximum fault current the breaker can safely interrupt.

This high rating is essential for systems with significant potential fault energy.

It prevents catastrophic damage to the breaker and electrical system during a fault.


Q9: Can this circuit breaker be remotely controlled or monitored?

This specific model, 3VA1180-6MH32-0AA0, is a standard TM version.

While it does not have built-in communication, accessories can be added.

Optional auxiliary contacts and communication modules allow for integration.


Q10: What are the dimensions of the Siemens 3VA1180-6MH32-0AA0?

Detailed dimensions are typically found in the product's technical datasheet.

The 3VA11 series is known for its compact size relative to its rating.

Consult the official Siemens documentation for precise physical specifications.

Menu