Siemens 3VA1216-5MH32-0AA0 3VA12 Series Molded Case Air Circuit Breaker 160A 250A 3P 55kA

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3VA1216-5MH32-0AA0
  • HS: 8536200000
Availability:In Stock
$196.98
zhongpingtech

The Siemens 3VA1216-5MH32-0AA0, a distinguished member of the 3VA12 Series Molded Case Air Circuit Breaker family, stands as a robust solution for industrial power distribution and protection. This 160A to 250A rated, 3-pole breaker boasts a significant 55kA interrupting capacity, ensuring reliable operation in demanding environments. Its advanced thermal-magnetic trip unit provides precise overcurrent and short-circuit protection, safeguarding critical electrical infrastructure. The Siemens 3VA1216-5MH32-0AA0 offers exceptional reliability and operational efficiency, making it a preferred choice for engineers and system integrators seeking high-performance circuit protection.


Product Specifications


| Parameter                   | Value                                |

| :-------------------------- | :----------------------------------- |

| Product Type                | Molded Case Air Circuit Breaker      |

| Series                      | 3VA12                                |

| Model Number                | 3VA1216-5MH32-0AA0                   |

| Rated Current (A)           | 160A                                 |

| Adjustable Current Range (A) | 160A - 250A                          |

| Number of Poles             | 3P                                   |

| Interrupting Capacity (kA)  | 55kA                                 |

| Trip Unit                   | Thermal-magnetic                     |

| Mounting Type               | Fixed                                |

| Connection Type             | Screw Terminal                       |

| Actuation Type              | Rotary Handle                        |

| Voltage Rating (AC)         | 690V                                 |

| Mechanical Endurance        | 20,000 switching cycles              |

| Electrical Endurance        | 8,000 switching cycles               |

| Standard Compliance         | IEC 60947-2, UL 489, CSA C22.2 No. 5 |


Core Features & Market Positioning


The Siemens 3VA1216-5MH32-0AA0 distinguishes itself through its highly reliable thermal-magnetic trip unit, offering adjustable settings for tailored protection. Its robust construction and adherence to international standards like IEC 60947-2 and UL 489 solidify its position as a dependable component in industrial electrical systems. The breaker’s high interrupting capacity of 55kA ensures safety even under severe fault conditions. Furthermore, its compatibility with a wide range of accessories, such as auxiliary and signaling contacts, enhances its versatility for sophisticated control and monitoring applications, a key differentiator in its market segment.


Key Application Scenarios


This molded case air circuit breaker is ideally suited for the main and branch circuit protection in industrial facilities, power distribution boards, and control panels. Its applications span across manufacturing plants, data centers, and commercial buildings where reliable power is paramount. The 3VA1216-5MH32-0AA0 is frequently specified for protecting motor feeders, transformer feeders, and generator connections, providing essential overcurrent and short-circuit safeguarding. Its robust design also makes it suitable for harsh environments and applications requiring frequent operational cycles.


Practical System Integration Guidance


Integrating the Siemens 3VA1216-5MH32-0AA0 into existing or new electrical systems is straightforward. The fixed mounting and screw terminal connections facilitate secure and efficient wiring. For optimal performance, ensure proper torque is applied to the terminals as per the manufacturer's recommendations to prevent overheating and ensure reliable electrical contact. Pre-installation checks should verify that the ambient temperature and environmental conditions are within the breaker's specified operating range. Proper phase sequencing and grounding connections are critical for safe and effective operation.


Operation and Risk Mitigation


Operating the Siemens 3VA1216-5MH32-0AA0 involves engaging the rotary handle to the ON or OFF position. Tripping occurs automatically during overcurrent or short-circuit events. To reset a tripped breaker, first identify and rectify the fault condition, then move the handle to the reset position before switching it back to the ON position. Regular visual inspections for any signs of damage or wear are recommended. In case of persistent nuisance tripping, recalibration or replacement of the trip unit may be necessary. Adhering to lockout/tagout procedures during maintenance is crucial for personnel safety.


Scalability & Long-Term Value


The Siemens 3VA1216-5MH32-0AA0 offers excellent long-term value through its compatibility with Siemens' broader automation and power distribution portfolio. While this specific model is fixed, the 3VA series allows for easy integration of various accessories, enhancing functionality over time. Its robust construction ensures a long operational lifespan, reducing the need for frequent replacements. For enhanced digital integration, Siemens offers communication modules that can be added to compatible breakers, enabling connection to SCADA systems and the Industrial Internet of Things (IIoT) for remote monitoring and predictive maintenance strategies.


Frequently Asked Questions


1. What is the primary function of the Siemens 3VA1216-5MH32-0AA0?


This breaker provides overcurrent and short-circuit protection. It safeguards electrical equipment from damage caused by excessive current.


It acts as a critical safety device in power distribution systems. The breaker interrupts the circuit when fault conditions are detected.


Its reliable operation ensures system integrity and prevents costly downtime. It is designed for industrial and commercial applications.


2. How do I adjust the current setting on the Siemens 3VA1216-5MH32-0AA0?


Access the trip unit to make adjustments. Ensure the breaker is de-energized and properly locked out.


Use the designated adjustment knobs or switches on the thermal-magnetic trip unit. Refer to the manual for precise setting procedures.


Proper adjustment is key to effective protection and preventing nuisance trips. Consult a qualified electrician if unsure.


3. Can the Siemens 3VA1216-5MH32-0AA0 be used for motor protection?


Yes, it is suitable for motor feeder protection. Its thermal-magnetic trip unit offers adjustable settings for motor starting currents.


Ensure the breaker's trip characteristics are coordinated with the motor's full load current and starting characteristics. Proper sizing is essential.


This breaker provides essential protection against motor overload and short circuits. It helps extend motor lifespan.


4. What are the key technical specifications of this breaker?


It's a 3-pole molded case air circuit breaker. It has a rated current of 160A and an adjustable range up to 250A.


The interrupting capacity is 55kA at 400/415V AC. It operates on a thermal-magnetic principle.


It complies with IEC 60947-2 and UL 489 standards. It features a fixed mounting type with screw terminals.


5. How do I install the Siemens 3VA1216-5MH32-0AA0?


Mount the breaker securely onto a suitable panel or busbar system. Ensure proper clearances are maintained.


Connect the incoming and outgoing power conductors to the designated terminals. Apply the correct torque to the screw terminals.


Before energizing, perform insulation resistance tests and verify all connections. Follow local electrical codes.


6. What is the interrupting capacity of the 3VA1216-5MH32-0AA0?


The breaker has an interrupting capacity of 55kA. This rating is at 400/415V AC.


This high rating means it can safely interrupt large fault currents. It provides robust protection against severe short circuits.


It is essential to match the breaker's interrupting capacity to the available fault current at the installation point.


7. Does this breaker support remote signaling or communication?


Optional accessories can enable remote signaling. Auxiliary and alarm contacts are available for monitoring status.


Communication modules can be added for integration into SCADA or IIoT systems. This allows for remote control and monitoring.


Check the specific accessory catalog for compatibility with the 3VA12 series. This enhances system visibility.


8. What is the difference between thermal and magnetic tripping?


Thermal tripping protects against sustained overloads. A bimetallic strip heats up and bends, tripping the breaker.


Magnetic tripping protects against short circuits. A coil generates a magnetic field that instantly trips the breaker on high current.


The combination provides comprehensive protection against various fault conditions. It is a standard in circuit breaker technology.


9. What is the mechanical and electrical endurance of this breaker?


The breaker has a mechanical endurance of 20,000 switching cycles. This refers to operations without load.


Its electrical endurance is rated at 8,000 switching cycles. This is for operations under load.


These ratings indicate a long service life for typical industrial applications. Proper operation preserves endurance.


10. Where can I find the official datasheet for the Siemens 3VA1216-5MH32-0AA0?


Official datasheets are typically available on the Siemens Industry website. You can search for the product number.


Distributor websites often provide downloadable product specification sheets. Ensure the source is reputable.


Consulting the datasheet is crucial for detailed technical information and installation guidelines. Always use the latest revision.