Siemens 3VA1116-6ED32-0AA0 3VA11 Series Molded Case Circuit Breaker 160A 3P 70kA

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:3VA1116-6ED32-0AA0
  • HS: 85362020
Availability:In Stock
$238.77
zhongpingtech

The Siemens 3VA1116-5EF32-0AA0 is a high-performance molded case air circuit breaker (MCCB) designed for robust protection in industrial electrical systems. This 3-pole breaker boasts a rated current of 160A and a breaking capacity of 55kA, making it suitable for demanding applications where reliable fault interruption is paramount. Its advanced technology ensures operational safety, efficient energy management, and seamless integration into modern power distribution networks.


Siemens 3VA1116-5EF32-0AA0: Product Specifications


| Parameter             | Value                                          |

| :-------------------- | :--------------------------------------------- |

| Product Type          | Molded Case Air Circuit Breaker (MCCB)         |

| Series                | 3VA                                            |

| Model Number          | 3VA1116-5EF32-0AA0                             |

| Number of Poles       | 3P (Three Poles)                               |

| Rated Current (Ie)    | 160A                                           |

| Rated Voltage (Ue)    | 690V AC                                        |

| Breaking Capacity (Icu) | 55kA at 400V AC                                |

| Trip Unit Type        | Electronic, adjustable                         |

| Overload Protection   | Adjustable (0.4 to 1.0) x In                   |

| Short-Circuit Protection| Adjustable (5 to 10) x In                      |

| Instantaneous Trip    | Adjustable (0.5 to 10) x In                    |

| Mounting Type         | Fixed, front or rear connection                |

| Auxiliary Contacts    | Yes (optional)                                 |

| Shunt Trip/Under-Voltage Release | Yes (optional)                          |

| Terminal Type         | Box terminals                                  |

| Standards Compliance  | IEC 60947-2                                    |

| Operating Temperature | -25 to +70 °C                                  |


Core Features & Market Positioning


The Siemens 3VA1116-5EF32-0AA0 stands out in the competitive MCCB market due to its robust design and advanced electronic trip unit. This unit offers highly flexible and precise protection settings for overload, short-circuit, and instantaneous trip functions, allowing for optimal coordination within electrical installations and minimizing nuisance tripping. Its high breaking capacity of 55kA ensures it can safely interrupt severe fault currents, a critical factor for industrial safety and equipment longevity. The 3VA series, to which this breaker belongs, is recognized for its reliability and ease of integration, positioning it as a preferred choice for engineers seeking dependable and adaptable circuit protection solutions.


Key Application Scenarios


This Siemens MCCB is engineered for a wide array of industrial applications, including motor protection, transformer protection, and main incomer protection in distribution boards. It is particularly well-suited for use in manufacturing plants, data centers, commercial buildings, and any facility requiring robust and reliable overcurrent and short-circuit protection for electrical circuits up to 160A. The adjustable trip settings allow for fine-tuning to specific load characteristics, ensuring efficient operation and enhanced safety for diverse machinery and electrical systems.


Practical System Integration Guidance


Integrating the Siemens 3VA1116-5EF32-0AA0 into existing or new electrical panels is straightforward, facilitated by its fixed mounting design and standard terminal configurations. For installation, ensure the breaker is mounted vertically or horizontally according to manufacturer guidelines, with adequate clearance for ventilation. Wiring connections should be made to the appropriate box terminals, ensuring proper torque is applied to prevent loose connections, which can lead to overheating. The electronic trip unit allows for straightforward adjustment of protection parameters (overload, short-circuit, ground fault if applicable) via intuitive controls directly on the breaker or through accessory modules, enabling precise customization for optimal system protection.


Operation and Risk Mitigation


Safe operation of the Siemens 3VA1116-5EF32-0AA0 relies on adherence to installation and maintenance guidelines. Regularly inspect terminals for signs of wear or corrosion and ensure all connections are secure. The breaker's trip unit provides clear indications of fault status, aiding in rapid troubleshooting. Common fault scenarios typically involve overload conditions due to equipment malfunction or excessive load, or short circuits caused by insulation failure or external damage. Understanding the adjustable parameters of the trip unit is crucial for diagnosing and resolving issues effectively, minimizing downtime and ensuring personnel safety.


Scalability & Long-Term Value


The Siemens 3VA1116-5EF32-0AA0 offers significant long-term value through its compatibility with the broader Siemens ecosystem and its inherent scalability. It can be easily integrated with various communication modules and auxiliary components, such as signaling contacts, shunt trips, and over-voltage releases, to enhance system functionality and monitoring capabilities. This makes it an ideal component for smart electrical grids and facilities moving towards digitalization and the Industrial Internet of Things (IIoT), allowing for remote monitoring, diagnostics, and integration into building management systems for optimized energy usage and predictive maintenance.


Frequently Asked Questions (FAQs)


What is the primary function of the Siemens 3VA1116-5EF32-0AA0?

This circuit breaker's main role is to protect electrical circuits from overcurrents and short circuits. It automatically interrupts the flow of electricity when a fault is detected. This prevents damage to downstream equipment and reduces the risk of electrical fires. Its 55kA breaking capacity ensures it can handle severe fault conditions.


How do I adjust the trip settings on the 3VA1116-5EF32-0AA0?

Adjustments are made using the electronic trip unit's controls. You can set the overload (Ir), short-circuit (Im), and instantaneous trip (Ii) thresholds. Refer to the product manual for precise instructions on setting these values according to your system's requirements. Proper adjustment is key for selectivity and reliable protection.


Can this breaker be used in both AC and DC applications?

The Siemens 3VA1116-5EF32-0AA0 is designed for AC applications, typically up to 690V. Its specifications are optimized for AC power systems and fault characteristics. Using it in DC systems may lead to improper operation or failure. Always verify application suitability with Siemens documentation.


What are the advantages of the electronic trip unit over thermal-magnetic ones?

Electronic trip units offer much greater precision and adjustability for protection settings. They provide independent adjustment of overload, short-circuit, and instantaneous trip functions. This allows for better system coordination and selective tripping, minimizing unnecessary power outages.


How does the 55kA breaking capacity benefit my electrical system?

A 55kA breaking capacity means the breaker can safely interrupt very high fault currents without being destroyed. This is crucial in industrial settings where fault levels can be significant, ensuring system integrity and preventing catastrophic failures. It provides a higher level of safety.


Is the Siemens 3VA1116-5EF32-0AA0 suitable for motor protection?

Yes, with its adjustable overload and short-circuit settings, this breaker is highly suitable for motor protection. The electronic trip unit can be precisely configured to match motor starting characteristics and running currents. This ensures reliable protection against motor burnout.


What type of terminals does this circuit breaker use?

The 3VA1116-5EF32-0AA0 is equipped with box terminals. These terminals accept a range of conductor sizes and provide secure connections for power distribution. Ensure correct conductor size and proper torque application during installation.


Are there optional accessories available for this breaker?

Yes, a range of accessories can enhance the functionality of this breaker. These include auxiliary contacts for signaling, shunt trip releases, and under-voltage releases for remote operation or protection. Communication modules can also be added for integration into digital systems.


What standards does the Siemens 3VA1116-5EF32-0AA0 comply with?

This circuit breaker complies with IEC 60947-2, which is the international standard for low-voltage switchgear and controlgear. Adherence to this standard ensures a high level of safety, performance, and reliability.


How do I ensure proper installation of this MCCB?

Proper installation involves mounting it securely, ensuring adequate ventilation, and correctly wiring the power and control circuits. Always follow the manufacturer's installation manual precisely. Proper torque on terminals is critical for safe and reliable operation.