DANFOSS FC-051PK37T4E20HXXXCXXXSXXX 0.37kW 480V Three Phase FC-051 VFD

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-051PK37T4E20HXXXCXXXSXXX
  • HS: 85044099.8
Availability:In Stock
$328.00
zhongpingtech

The DANFOSS FC-051PK37T4E20HXXXCXXXSXXX, a 0.37kW, 480V three-phase FC-051 Variable Frequency Drive (VFD), stands as a robust solution for precise motor control in demanding industrial environments. This VFD excels in energy efficiency, offering significant operational cost savings through optimized power delivery. Its compact design facilitates easy installation even in space-constrained panels, while advanced control algorithms ensure smooth acceleration, deceleration, and speed regulation, minimizing mechanical stress on driven equipment. Key technical parameters include a power rating of 0.37 kW, an input voltage of 480V (three-phase), and output frequency control up to 500 Hz, making it suitable for a wide range of motor applications. The FC-051 series is engineered for reliability, featuring robust thermal management and protection against electrical disturbances, ensuring continuous operation and extended equipment lifespan.


| Parameter           | Specification                               |

| ------------------- | ------------------------------------------- |

| Model Number        | FC-051PK37T4E20HXXXCXXXSXXX                  |

| Power Rating        | 0.37 kW                                     |

| Input Voltage       | 480V, Three Phase                           |

| Output Frequency    | Up to 500 Hz                                |

| Enclosure           | IP20 (standard)                             |

| Control Method      | V/Hz, Advanced V/Hz, Vector Control         |

| Communication       | Optional fieldbus modules available         |

| Ambient Temperature | -10°C to +50°C (derating may apply)          |


Core Features & Market Positioning


The DANFOSS FC-051PK37T4E20HXXXCXXXSXXX distinguishes itself through its adaptive control capabilities, offering both V/Hz and advanced vector control modes to suit varying application requirements. This flexibility allows users to achieve precise torque and speed control, even with challenging loads, a critical factor for maintaining process integrity. Its market positioning is firmly rooted in providing reliable, energy-efficient motor control without the complexity often associated with higher-end VFDs. The integrated braking transistor (in most configurations) and optional braking resistors provide effective deceleration control, further enhancing its utility in applications with high inertia loads. Danfoss's commitment to user-friendly design is evident in its intuitive parameter programming, simplifying setup and maintenance for plant engineers.


Key Application Scenarios


This 0.37kW VFD is ideally suited for a diverse array of industrial applications where precise motor speed and torque management are paramount. Common scenarios include centrifugal pumps and fans, where VFD control can yield substantial energy savings by matching motor speed to system demand, thus avoiding inefficient throttling or damping. It is also highly effective in conveyor systems, mixers, and extruders, where controlled acceleration and deceleration are crucial for product quality and reduced mechanical wear. Machine tool applications, such as spindle drives, benefit from the VFD's ability to provide variable speeds and precise torque, enabling optimized machining processes. Furthermore, its robust construction makes it a reliable choice for HVAC systems and other general-purpose industrial machinery.


Practical System Integration Guidance


Integrating the DANFOSS FC-051PK37T4E20HXXXCXXXSXXX into an existing system involves careful consideration of electrical connections and control logic. For wiring, ensure the incoming power supply (480V, three-phase) is correctly connected to the L1, L2, and L3 terminals, and the motor is connected to T1, T2, and T3. Grounding is essential for safety and proper operation; connect the protective earth terminal to a reliable ground. For control signals, use the digital or analog input terminals to interface with PLCs or other control systems. Parameter programming is typically accessed via the VFD's keypad or through PC-based software like Danfoss's MCT 10. Initial setup often involves setting motor data (nominal voltage, current, frequency, poles) and basic operational parameters like acceleration/deceleration times to prevent nuisance tripping and ensure smooth system response.


Operation and Risk Mitigation


Safe and efficient operation of the DANFOSS FC-051PK37T4E20HXXXCXXXSXXX mandates adherence to safety protocols and an understanding of its fault management system. Always ensure the VFD is properly grounded and that the motor is disconnected from power before making any wiring changes. During commissioning, perform a thorough check of all connections and ensure the ambient temperature and environmental conditions are within the VFD's operating limits to prevent overheating. Common fault codes, such as 'Overcurrent' (F001) or 'Overtemperature' (F004), often indicate issues with motor load, wiring, or cooling. Reviewing the user manual for specific fault code explanations and recommended corrective actions is critical for swift troubleshooting and minimizing downtime. Implementing appropriate motor overload protection and surge suppression can further mitigate operational risks.


Scalability & Long-Term Value


The DANFOSS FC-051PK37T4E20HXXXCXXXSXXX offers a degree of scalability and contributes to long-term value through its inherent efficiency and compatibility. While this specific 0.37kW unit is designed for smaller applications, the FC-051 platform supports a range of power ratings, allowing for standardized deployment across various machinery within a facility. Integration with industrial automation systems is facilitated through optional communication modules that support common fieldbus protocols (e.g., Modbus, Profibus), enabling seamless data exchange and remote control capabilities. This connectivity is a foundational element for implementing Industry 4.0 initiatives, such as predictive maintenance and enhanced process monitoring. The VFD's energy-saving capabilities directly translate into reduced operational expenditure over its lifespan, enhancing the overall return on investment.


Frequently Asked Questions

  What are the primary benefits of using the DANFOSS FC-051PK37T4E20HXXXCXXXSXXX?

    This VFD offers significant energy savings by precisely controlling motor speed to match load requirements. It enhances system reliability and reduces mechanical stress on equipment through soft start and stop capabilities. The compact design simplifies installation in various industrial settings.

  How does the DANFOSS FC-051PK37T4E20HXXXCXXXSXXX handle different motor types and loads?

    The drive supports multiple control modes, including V/Hz and advanced vector control, allowing optimization for various motor characteristics. It is suitable for both constant torque and variable torque loads, such as pumps and fans.

  What are the typical installation considerations for this VFD?

    Ensure adequate ventilation around the unit to prevent overheating and derating. Proper grounding is crucial for electrical safety and noise reduction. Select appropriate cable sizes for both power input and motor output.

  Can the DANFOSS FC-051PK37T4E20HXXXCXXXSXXX be controlled remotely?

    Yes, remote control is possible using digital or analog input terminals for commands and speed setpoints. Optional communication modules enable integration with SCADA systems and PLCs via standard industrial networks.

  What are common fault codes for the FC-051 series and how should they be addressed?

    Common faults include overcurrent, overvoltage, and overtemperature. These typically indicate issues with the motor, wiring, or installation environment. Consult the manual for specific code meanings and troubleshooting steps.

  Does this VFD offer built-in protection features?

    The DANFOSS FC-051PK37T4E20HXXXCXXXSXXX includes comprehensive motor and drive protection functions. These cover overcurrent, overvoltage, undervoltage, phase loss, and thermal overload.

  What is the IP rating of the DANFOSS FC-051PK37T4E20HXXXCXXXSXXX?

    The standard enclosure for this VFD series is IP20, meaning it is protected against solid objects greater than 12.5 mm and offers no protection against water. For harsher environments, consider alternative enclosures or mounting solutions.

  How does the advanced V/Hz control differ from standard V/Hz control?

    Advanced V/Hz provides better torque control at lower speeds compared to standard V/Hz. It offers a more linear relationship between voltage and frequency for improved performance.

  Can this VFD be used with a braking resistor?

    Yes, the FC-051 series often includes an integrated braking transistor and can be utilized with external braking resistors for applications requiring rapid deceleration and energy dissipation.

  What is the typical lifespan and maintenance schedule for this VFD?

    With proper installation and operation within specified environmental limits, these VFDs are designed for a long service life. Periodic visual inspections and filter cleaning are generally recommended, alongside monitoring for any abnormal operational parameters.

Menu