Siemens 5SN6210-7CN MCB for Low Voltage Distribution 2P 10A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6210-7CN
  • HS: 85362030
Availability:In Stock
$7.68
zhongpingtech

The Siemens 5SN6210-7CN MCB is a critical component for robust low-voltage electrical distribution systems, offering superior protection and reliability. This 2-pole, 10-amp Miniature Circuit Breaker (MCB) is engineered for demanding industrial and commercial environments, safeguarding circuits against overcurrents and short circuits. Its compact design, high breaking capacity, and compliance with international standards make it a preferred choice for system integrators and electrical engineers seeking dependable performance and safety. Key advantages include its quick trip mechanism, durability, and seamless integration into standard distribution boards.


Product Specifications


| Feature             | Specification                   |

| :------------------ | :------------------------------ |

| Product Type        | Miniature Circuit Breaker (MCB) |

| Manufacturer        | Siemens                         |

| Model Number        | 5SN6210-7CN                     |

| Poles               | 2P                              |

| Rated Current (In)  | 10A                             |

| Rated Voltage (Ue)  | 400V AC                         |

| Breaking Capacity (Icn) | 6kA                             |

| Tripping Curve      | C                               |

| Frequency           | 50/60 Hz                        |

| Terminal Type       | Screw Terminal                  |

| Mounting Type       | DIN Rail                        |

| Protection Degree   | IP20                            |

| Compliance          | IEC/EN 60898-1                  |


Core Features & Market Positioning


The Siemens 5SN6210-7CN MCB distinguishes itself through its robust construction and adherence to stringent quality standards. As part of Siemens' comprehensive portfolio of low-voltage protective devices, this MCB embodies the brand's commitment to innovation and reliability in electrical infrastructure. Its C-curve tripping characteristic makes it ideal for applications with moderate inrush currents, such as lighting systems, motors, and distribution circuits, effectively balancing sensitivity to faults with tolerance for transient loads. This precise engineering ensures optimal circuit protection without nuisance tripping, a crucial factor in maintaining operational continuity and reducing maintenance overheads in commercial and industrial settings. The 6kA breaking capacity provides a significant safety margin for typical distribution networks.


Key Application Scenarios


This 2-pole, 10A MCB is extensively utilized in various low-voltage distribution applications. It serves as a primary protective device for individual circuits within electrical panels, ensuring the safety of equipment and personnel. Common scenarios include protecting branch circuits for lighting, socket outlets, and small machinery in industrial plants, commercial buildings, and residential complexes. Its compatibility with standard DIN rail mounting systems facilitates its integration into new installations and retrofits, making it a versatile solution for safeguarding power supplies for HVAC systems, control panels, and communication equipment where a 10A rating is appropriate.


Practical System Integration Guidance


Integrating the Siemens 5SN6210-7CN MCB is straightforward due to its standardized design. It mounts securely onto a standard 35mm DIN rail, allowing for quick and efficient installation within electrical enclosures and distribution boards. The clearly marked screw terminals accommodate standard wiring gauges for line and neutral conductors, simplifying connections. Proper wire termination, ensuring adequate torque and insulation stripping, is crucial for a safe and reliable connection. For a 2-pole device, both the live and neutral conductors must be connected to ensure complete isolation of the circuit during fault conditions or maintenance. Always ensure the main power supply to the distribution board is de-energized before performing any installation or wiring work.


Operation and Risk Mitigation


The Siemens 5SN6210-7CN MCB operates by sensing overcurrents (overloads and short circuits) and automatically interrupting the electrical circuit to prevent damage to connected equipment and mitigate fire hazards. The C-curve allows for higher magnetic trip currents (typically 5-10 times the rated current) compared to a B-curve, making it suitable for inductive loads. To mitigate risks, ensure the MCB is correctly rated for the load it protects and that the breaking capacity (6kA) is sufficient for the prospective fault current at the installation point. Regular visual inspections for damage and periodic testing of the tripping function, in accordance with local electrical codes and standards, are recommended to ensure continued operational integrity and safety. Avoid operating the manual trip lever unnecessarily, as this can lead to premature wear.


Scalability & Long-Term Value


The Siemens 5SN6210-7CN MCB offers excellent long-term value through its durability and compatibility with the broader Siemens industrial control and automation ecosystem. While this specific model is a standalone protective device, its integration into Siemens' product lines ensures that it aligns with future system expansions and upgrades. For more advanced scalability, Siemens offers a wide range of circuit breakers and related components that can be integrated into larger power management systems, including those supporting IIoT and digital monitoring solutions. This forward compatibility ensures that investments in Siemens protective devices can be leveraged as digital transformation progresses within industrial facilities.


Frequently Asked Questions (FAQs)


Q1: What is the breaking capacity of the Siemens 5SN6210-7CN MCB?

This MCB features a breaking capacity of 6kA. This rating indicates the maximum fault current it can safely interrupt.

It ensures protection against severe short-circuit events in low-voltage distribution systems. A higher breaking capacity provides greater safety margin.


Q2: What type of loads is the Siemens 5SN6210-7CN MCB suitable for?

The C-curve tripping characteristic makes it ideal for inductive loads. This includes small motors and lighting systems.

It can handle moderate inrush currents without nuisance tripping. This ensures reliable operation for such applications.


Q3: Can the Siemens 5SN6210-7CN MCB be used in residential applications?

Yes, it can be used for residential applications requiring a 2-pole, 10A circuit breaker. It meets IEC/EN 60898-1 standards.

However, local electrical codes may specify different curve types or ratings. Always consult local regulations for compliance.


Q4: How do I install the Siemens 5SN6210-7CN MCB?

Installation involves mounting it on a standard 35mm DIN rail. Connect the line and neutral conductors to the designated screw terminals.

Ensure power to the panel is off before wiring. Torque terminals properly for a secure connection.


Q5: What does the "2P" designation mean for this MCB?

"2P" signifies that the circuit breaker has two poles. This means it can simultaneously switch and protect both the live and neutral conductors of a circuit.

This provides complete isolation for single-phase circuits. It enhances safety during maintenance or fault conditions.


Q6: What is the rated current (In) of the Siemens 5SN6210-7CN MCB?

The rated current (In) for this MCB is 10 Amperes (A). This is the maximum continuous current the device can safely carry under normal operating conditions.

It is crucial to select an MCB with a rated current appropriate for the connected load. Exceeding this can lead to overheating and damage.


Q7: What is the significance of the "C" in the tripping curve?

The "C" designation refers to the tripping curve type. A C-curve MCB has a magnetic trip range of 5 to 10 times the rated current.

This makes it suitable for loads with moderate inrush currents. It prevents premature tripping caused by temporary surges.


Q8: What voltage rating is appropriate for the Siemens 5SN6210-7CN MCB?

The rated voltage (Ue) for this MCB is 400V AC. This is standard for low-voltage distribution systems in many regions.

Ensure the MCB's voltage rating matches or exceeds the system voltage. Using an undersized voltage rating is a safety hazard.


Q9: What does IP20 protection mean for this MCB?

IP20 indicates the degree of protection against solid objects and water. It means the device is protected against solid objects larger than 12.5mm.

It is not protected against water ingress. Therefore, it should be installed in an enclosure to protect it from dust and moisture.


Q10: Where can I find more technical documentation for this product?

Detailed technical specifications, datasheets, and installation manuals are typically available on the official Siemens Industry Online Support (SIOS) portal. You can also consult the product's packaging or contact Siemens technical support.

Searching on the SIOS portal using the exact product number "5SN6210-7CN" will yield the most accurate and comprehensive documents. Always refer to the latest revisions of documentation for current information.

Menu