Siemens 5SN6263-7CN Miniature Circuit Breaker 2P 63A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6263-7CN
  • HS: 85362030
Availability:In Stock
$12.99
zhongpingtech

The Siemens 5SN6263-7CN Miniature Circuit Breaker (MCB) stands as a robust and reliable solution for overcurrent protection in various electrical installations. Designed for demanding industrial and commercial applications, this 2-pole, 63A MCB offers superior performance and safety. Its core advantages lie in its high breaking capacity, dependable tripping characteristics, and compact design, ensuring efficient and secure power distribution. With a rated voltage of 400V AC and a tripping curve of C, the 5SN6263-7CN is engineered to handle inductive loads and prevent nuisance tripping, a critical factor in maintaining operational continuity. The unit's robust construction and adherence to stringent international standards, such as IEC/EN 60898-1, underscore its suitability for professional electrical projects where precision and longevity are paramount.


Siemens 5SN6263-7CN Miniature Circuit Breaker: Specifications


| Parameter                 | Value                 |

| :------------------------ | :-------------------- |

| Product Type              | Miniature Circuit Breaker |

| Manufacturer              | Siemens               |

| Model Number              | 5SN6263-7CN           |

| Poles                     | 2                     |

| Rated Current (In)        | 63 A                  |

| Rated Voltage (Ue)        | 400V AC               |

| Tripping Characteristic   | C                     |

| Breaking Capacity (Icn)   | 6 kA                  |

| Frequency                 | 50/60 Hz              |

| Insulation Voltage (Ui)   | 500V                  |

| Degree of Protection      | IP20                  |

| Mounting Type             | DIN Rail              |

| Operating Temperature     | -25°C to 45°C         |

| Compliance Standards      | IEC/EN 60898-1        |


Core Features & Market Positioning


The Siemens 5SN6263-7CN MCB distinguishes itself through its inherent Siemens quality and advanced protection capabilities. Its Type C tripping curve is particularly advantageous for applications with moderate inrush currents, common in motor starting or lighting circuits, offering effective protection without excessive sensitivity. The 6 kA breaking capacity ensures that the device can safely interrupt fault currents, preventing damage to downstream equipment and mitigating fire hazards. This level of performance positions the 5SN6263-7CN as a dependable choice for panel builders and electrical engineers who prioritize safety, reliability, and compliance with international electrical codes. The product's integration into Siemens' comprehensive portfolio of electrical components also signifies excellent compatibility and support within established electrical infrastructure.


Key Application Scenarios


This Siemens MCB is ideally suited for a wide array of applications, including the protection of distribution circuits in commercial buildings, industrial facilities, and residential complexes. Its 2-pole configuration makes it essential for switching both live and neutral conductors simultaneously, ensuring complete isolation, which is critical for maintenance and safety procedures. Common use cases involve protecting circuits feeding machinery, HVAC systems, lighting arrays, and power outlets where inductive loads are prevalent. The 63A rating is appropriate for main distribution or branch circuits requiring substantial current-carrying capacity. In summary, the 5SN6263-7CN is a versatile protective device for scenarios demanding robust overcurrent and short-circuit protection for 230/400V single-phase or three-phase systems.


Practical System Integration Guidance


Integrating the Siemens 5SN6263-7CN MCB into existing or new electrical systems is straightforward, leveraging standard DIN rail mounting for quick and secure installation within distribution boards and control panels. Ensure that the ambient temperature remains within the specified operating range of -25°C to 45°C for optimal performance. For wiring, connect the incoming power supply to the designated terminals, typically marked with "L" for line and "N" for neutral on each pole, ensuring correct polarity. The outgoing load connections should be made to the downstream terminals. It is imperative to verify that the cable cross-sectional area is appropriate for the 63A rated current and adheres to local electrical codes. Proper torque should be applied to the terminal screws to prevent loose connections, which can lead to overheating and potential failure.


Operation and Risk Mitigation


The Siemens 5SN6263-7CN operates automatically, interrupting the circuit when an overcurrent (overload or short circuit) exceeds its calibrated threshold, preventing damage to connected equipment and wiring. The Type C tripping characteristic means it will trip between 5 to 10 times the rated current, accommodating typical inrush currents without unwarranted disconnection. To mitigate risks, always ensure the MCB is rated correctly for the load and that the wiring is adequately sized. Regular visual inspections of the MCB and its connections for any signs of damage, discoloration, or overheating are recommended. If the MCB trips repeatedly, it indicates a persistent overcurrent issue that requires investigation by a qualified electrician to identify and rectify the underlying fault, rather than attempting to reset the breaker repeatedly.


Scalability & Long-Term Value


The Siemens 5SN6263-7CN MCB offers significant long-term value due to its robust design and compatibility with Siemens' broader electrical infrastructure. While MCBs themselves are protective devices and not directly scalable in terms of capacity by adding features, their value is realized through their reliability and integration potential. This unit is designed for seamless integration into standard Siemens switchgear and distribution systems, facilitating future expansions or modifications of the electrical network. Its compliance with international standards ensures continued relevance and availability of replacement parts or compatible components. For enhanced system intelligence, consider integrating it within a smart panel system, allowing for remote monitoring and diagnostics when paired with appropriate communication modules, aligning with Industry 4.0 initiatives.


Frequently Asked Questions (FAQs)


What is the tripping characteristic of the Siemens 5SN6263-7CN MCB?

The Siemens 5SN6263-7CN features a Type C tripping characteristic. This means it is designed to trip when the current reaches 5 to 10 times its rated current of 63A.


This characteristic is ideal for circuits with moderate inductive loads or inrush currents, such as those powering motors or lighting systems. It helps prevent nuisance tripping while still providing essential overcurrent protection.


Therefore, for applications sensitive to transient currents but requiring reliable circuit interruption during significant faults, the Type C curve is a suitable choice.


What is the breaking capacity of the Siemens 5SN6263-7CN?

This Siemens MCB has a breaking capacity of 6 kA. This refers to the maximum fault current it can safely interrupt without being damaged.


A 6 kA breaking capacity is adequate for many residential, commercial, and light industrial applications. It ensures the device can effectively disconnect power during a short circuit.


When selecting an MCB, it is crucial to ensure its breaking capacity exceeds the prospective short-circuit current at the point of installation to guarantee safety.


Can the Siemens 5SN6263-7CN be used for single-phase or three-phase applications?

The Siemens 5SN6263-7CN is a 2-pole miniature circuit breaker. It is designed to switch both the line and neutral conductors simultaneously.


It is commonly used in single-phase circuits where isolating both conductors is required for safety, such as in many residential and commercial power distribution systems.


While it protects two conductors, for three-phase applications, it would typically be used in conjunction with other 2-pole MCBs or specific 3-pole MCBs, depending on the system's protective requirements.


What type of loads is the Siemens 5SN6263-7CN best suited for?

This MCB, with its Type C tripping curve, is well-suited for inductive loads. These often exhibit higher inrush currents upon startup.


Examples include motors, transformers, and fluorescent lighting ballasts, which can momentarily draw significantly more current than their steady-state operating levels. The Type C characteristic allows for these temporary surges without tripping.


It is also suitable for general power distribution and protection of circuits with moderate inrush currents in commercial and industrial environments.


How does the 63A rating of the Siemens 5SN6263-7CN affect its application?

The 63A rating indicates the maximum continuous current the circuit breaker can carry without tripping. This is a key factor in determining the appropriate use for specific circuits.


This rating makes the 5SN6263-7CN suitable for protecting circuits with substantial power requirements, such as main distribution feeders or circuits supplying heavy machinery.


It is essential to match the MCB's current rating to the load's expected continuous current draw and the conductor's capacity to prevent overloading and ensure safe operation.


What are the main advantages of using a Siemens MCB like the 5SN6263-7CN?

Siemens MCBs are renowned for their high reliability and adherence to stringent quality standards, ensuring dependable circuit protection. The 5SN6263-7CN offers robust overcurrent and short-circuit protection.


Its compact 2-pole design facilitates space-saving installations in electrical panels, while the Type C tripping curve provides effective protection for inductive loads. This minimizes nuisance tripping and enhances operational continuity.


The product's compliance with international standards like IEC/EN 60898-1 guarantees performance and safety, making it a trusted choice for professional electrical installations.


Is the Siemens 5SN6263-7CN suitable for domestic or industrial use?

The Siemens 5SN6263-7CN is designed for a broad range of applications, making it suitable for both industrial and demanding commercial environments. Its robust construction and 6 kA breaking capacity cater to higher-risk applications.


While capable of industrial use, its specifications also align with the requirements for advanced protection in larger residential complexes or areas with significant electrical loads. It offers a higher level of protection than typically found in basic domestic MCBs.


Ultimately, its suitability depends on the specific electrical code requirements and the protection needs of the circuit it is installed in, offering a versatile solution.


What installation considerations are important for the Siemens 5SN6263-7CN?

Proper installation is crucial for safety and performance. The MCB must be mounted on a standard 35mm DIN rail within an appropriate enclosure.


Ensure the correct torque is applied to the terminal screws to secure connections firmly, preventing potential overheating or loose connections. Correct polarity must be observed when connecting line and neutral conductors.


Always confirm that the cable size is adequate for the 63A rating and complies with local electrical regulations and standards to ensure safe and reliable operation.


What does the "2P" designation signify on the Siemens 5SN6263-7CN?

The "2P" designation indicates that the circuit breaker has two poles. Each pole is designed to protect and switch a separate electrical conductor.


In this case, it means the MCB can simultaneously interrupt both the live (line) and the neutral conductor of a circuit. This provides complete isolation when the breaker is switched off, enhancing safety during maintenance.


This 2-pole configuration is common in single-phase systems where switching off both conductors is a safety requirement, or in specific industrial control circuits.


How does the Siemens 5SN6263-7CN contribute to electrical safety?

The primary function of this MCB is to protect electrical circuits from damage caused by overcurrents and short circuits, thereby preventing potential hazards like fires. Its automatic tripping mechanism ensures rapid disconnection of power.


By interrupting the circuit when fault conditions are detected, it safeguards wiring from overheating and prevents damage to sensitive electrical equipment connected downstream, extending their lifespan.


The 2-pole design also enhances safety by allowing for complete isolation of both live and neutral conductors, which is critical for preventing electrical shock during maintenance or repair work.