Siemens 5SN6408-7CN MCB for Motor Overload Protection 4P 8A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SN6408-7CN
  • HS: 85362030
Availability:In Stock
$20.22
zhongpingtech

The Siemens 5SN6408-7CN MCB is a high-performance Miniature Circuit Breaker designed specifically for robust motor overload protection. This 4-pole, 8-amp device offers superior circuit integrity with a tripping characteristic curve C, ensuring reliable operation and safeguarding sensitive motor equipment. Its compact design, quick-make/quick-break mechanism, and compliance with stringent international standards make it a premier choice for industrial applications demanding safety and efficiency. Key technical parameters include a rated voltage of 400V AC, a rated breaking capacity of 6kA, and an ambient temperature range of -25°C to +45°C.


Product Specifications


| Parameter                 | Specification              |

| :------------------------ | :------------------------- |

| Product Type              | Miniature Circuit Breaker  |

| Manufacturer              | Siemens                    |

| Series                    | 5SN6                       |

| Poles                     | 4                          |

| Rated Current (In)        | 8 A                        |

| Tripping Characteristic   | C                          |

| Rated Voltage (Ue)        | 400 V AC                   |

| Rated Breaking Capacity (Icn) | 6 kA                     |

| Frequency                 | 50/60 Hz                   |

| Ambient Temperature Range | -25°C to +45°C             |

| Protection Class          | IP20                       |

| Mounting Type             | DIN Rail                   |

| Standards Compliance      | IEC/EN 60898-1, IEC/EN 60947-2 |


Core Features & Market Positioning


The Siemens 5SN6408-7CN MCB distinguishes itself through its advanced thermal-magnetic tripping mechanism, providing precise and reliable protection against overcurrents and short circuits, thereby preventing motor damage and minimizing downtime. Its characteristic curve C is optimized for inductive loads like motors, offering a balance between inrush current immunity and overload sensitivity. As a 4-pole breaker, it ensures complete isolation for three-phase systems, enhancing safety and compliance. Positioned as a dependable and cost-effective solution, it competes effectively in the industrial automation and electrical distribution markets where long-term reliability and adherence to safety standards are paramount.


Key Application Scenarios


This MCB is ideally suited for protecting electric motors in various industrial settings, including manufacturing plants, pump stations, HVAC systems, and conveyor belts. Its application is critical in environments where motors are subject to frequent start-ups and potential overloads, such as in automated production lines. The 4-pole configuration is essential for comprehensive protection of three-phase motor circuits. Furthermore, its compliance with international standards makes it a suitable component for globally deployed machinery and control panels.


Practical System Integration Guidance


Integrating the Siemens 5SN6408-7CN MCB into existing or new electrical systems is straightforward due to its standard DIN rail mounting and clear terminal markings. For wiring, ensure that the line and load terminals are correctly identified and that all four poles are connected to the respective phases and neutral conductors of the motor circuit. Proper torque must be applied to the terminals to ensure secure connections and prevent overheating. Commissioning involves a visual inspection and a functional test to verify correct tripping under simulated overload conditions, ensuring the protective settings align with motor nameplate data and application requirements.


Operation and Risk Mitigation


Operation of the Siemens 5SN6408-7CN MCB is managed via its clearly marked toggle lever, which indicates the circuit status (ON/OFF/TRIPPED). Risk mitigation is primarily achieved through its inherent protective functions. In case of overload, the thermal element trips the breaker, while a short circuit triggers a rapid magnetic trip, preventing catastrophic damage to the motor windings or connected wiring. Users should regularly inspect the breaker for signs of wear or damage and ensure the ambient temperature remains within the specified operating range to maintain optimal performance and prevent premature tripping or failure.


Scalability & Long-Term Value


The Siemens 5SN6408-7CN MCB is part of Siemens' extensive range of industrial electrical components, offering excellent compatibility with other Siemens circuit protection devices, contactors, and motor starters. This compatibility facilitates seamless integration into larger control systems and enables straightforward system expansion or upgrades. For businesses embracing Industry 4.0, while this specific MCB may not have built-in digital communication, it can be effectively integrated into smart power monitoring systems through compatible downstream components or associated smart meters, providing valuable data for energy management and predictive maintenance.


Frequently Asked Questions


What is the primary function of the Siemens 5SN6408-7CN MCB?

This MCB's core purpose is to provide reliable overload and short-circuit protection for electric motors. It safeguards equipment from damage caused by excessive current.


It actively monitors the circuit's current draw, tripping the circuit when predefined limits are exceeded. This prevents thermal stress on motor windings and associated wiring.


The device ensures operational safety and extends the lifespan of motor-driven equipment by preventing costly failures due to electrical faults.


What does the 'C' in the tripping characteristic 'C' signify for this MCB?

A "C" characteristic indicates the MCB is designed for circuits with moderate inrush currents. This is typical for inductive loads like electric motors.


It offers a balance, tolerating short, high-current surges during motor startup without tripping unnecessarily. However, it still provides rapid tripping for sustained overloads.


This makes the 5SN6408-7CN suitable for motor applications where startup surges are expected but reliable overload protection is crucial.


Can this MCB be used for single-phase motors?

While the 5SN6408-7CN is a 4-pole breaker, it can be adapted for single-phase motor protection by using three poles and leaving one pole unused, or by ensuring proper wiring configurations for single-phase loads.


For single-phase circuits, it's crucial to correctly wire two poles for the live and neutral conductors to ensure comprehensive protection of the single-phase motor.


However, for optimal application and to leverage its full capabilities, it is most appropriately used in three-phase motor circuits, which require protection on all three active conductors.


What is the rated breaking capacity (Icn) of this MCB, and why is it important?

The rated breaking capacity (Icn) of the Siemens 5SN6408-7CN MCB is 6kA. This specifies the maximum fault current the MCB can safely interrupt without sustaining damage.


A higher Icn rating ensures the MCB can withstand and safely disconnect severe short-circuit conditions. This is critical for preventing arc flash hazards and ensuring personnel safety.


Selecting an MCB with an Icn rating appropriate for the system's prospective fault current is vital for reliable protection and system integrity.


How do I correctly wire the Siemens 5SN6408-7CN MCB for a three-phase motor?

For a three-phase motor, connect each of the three live conductors from the power supply to three of the MCB's input terminals. The fourth terminal is typically unused for three-phase applications unless specific configurations require it.


The output terminals corresponding to the connected input terminals should then be wired to the three-phase motor's power terminals. Ensure all connections are secure and torqued correctly as per manufacturer guidelines.


Always refer to the wiring diagram provided with the MCB and consult a qualified electrician to ensure correct and safe installation according to local electrical codes.


What is the significance of the 4-pole configuration in this MCB?

A 4-pole MCB provides protection and isolation across all four conductors of a circuit, including the neutral in certain systems. For three-phase motors, it disconnects all three phases simultaneously.


This ensures complete circuit isolation, which is crucial for safety during maintenance and for preventing unbalanced load conditions. It offers a higher level of protection than 3-pole breakers in specific industrial scenarios.


The 4-pole design is standard for protecting three-phase circuits where neutral conductor switching is also required or for systems demanding maximum protection against phase-to-phase and phase-to-neutral faults.


What are the environmental operating limits for this MCB?

The Siemens 5SN6408-7CN MCB is designed to operate within an ambient temperature range of -25°C to +45°C. Deviating from this range can affect its performance.


Operating outside the specified temperature range can lead to nuisance tripping (if too hot) or reduced sensitivity (if too cold), compromising its protective function. It is also important to consider humidity and dust.


Ensure the installation environment is suitable and that adequate ventilation is provided to maintain the MCB within its operational parameters for optimal lifespan and reliability.


Where is the Siemens 5SN6408-7CN MCB typically used in industrial automation?

This MCB is commonly employed in motor control centers (MCCs) and electrical distribution boards for protecting individual motor loads. It's found in applications such as conveyor systems, pumps, fans, and compressors.


Its role is to provide localized protection for each motor, preventing faults in one motor circuit from affecting others. This granular protection is essential for maintaining plant uptime and preventing cascading failures.


The 'C' curve characteristic makes it well-suited for motors with standard starting currents found across various automated manufacturing and processing industries.


Does this MCB offer adjustable settings for overload protection?

The Siemens 5SN6408-7CN MCB features fixed overload protection settings defined by its 8A rating and 'C' characteristic curve. It does not have adjustable trip settings for overload current or time delay.


For applications requiring adjustable protection, Siemens offers other series of circuit breakers or motor protection relays that provide these advanced functionalities. This fixed setting ensures simplicity and reliability for standard motor applications.


Users must ensure that the fixed 8A rating and 'C' characteristic are appropriate for the specific motor's full-load current and starting characteristics before installation.


How does this MCB contribute to electrical safety in industrial environments?

This MCB significantly enhances electrical safety by rapidly interrupting fault currents, thereby preventing electrical fires and protecting personnel from electric shock hazards. Its robust construction and compliance with international safety standards (IEC/EN) ensure dependable performance.


By isolating faulty circuits, it prevents damage to expensive equipment and minimizes the risk of system-wide blackouts. The clear ON/OFF indication also aids in safe operational procedures and maintenance practices.


The thermal-magnetic tripping mechanism provides a dual layer of protection: thermal for sustained overloads and magnetic for instantaneous short-circuit protection, covering a broad spectrum of electrical fault scenarios.