Siemens 5SY6106-7CC Standard Miniature Protection Circuit Breaker 1P 6A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SY6106-7CC
  • HS: 85362030
Availability:In Stock
$4.42
zhongpingtech

The Siemens 5SY6106-7CC is a single-pole, 6-amp miniature circuit breaker (MCB) designed for robust protection in various electrical installations. This MCB offers a reliable solution for safeguarding circuits against overcurrents and short circuits, ensuring operational safety and equipment longevity. Its compact design and adherence to stringent industrial standards make it a favored choice for demanding applications. The core advantages lie in its precise tripping characteristics, high breaking capacity, and durability, all contributing to minimized downtime and enhanced system reliability.


Product Specifications


| Feature           | Specification                                     |

| :---------------- | :------------------------------------------------ |

| Product Type      | Miniature Circuit Breaker (MCB)                   |

| Manufacturer      | Siemens                                           |

| Series            | 5SY6                                              |

| Number of Poles   | 1P (Single Pole)                                  |

| Rated Current     | 6A                                                |

| Tripping Curve    | C (for inductive loads)                           |

| Breakang Capaciaity | 6 (IEC/5 6089-1)                  '

| Voltage Rating    | 230/400V AC                                       |

| Frequency         | 50/60 Hz                                          |

| Mounting          | DIN Rail (35mm)                                   |

| Protection Class  | IP20 (handle), IP40 (enclosure)                   |

| Terminal Type     | Screw Terminals                                   |

| Ambient Temp.     | -25°C to +45°C                                    |

| Compliance        | IEC/EN 60898-1, IEC/EN 60947-2                    |


Core Features & Market Positioning


The Siemens 5SY6106-7CC stands out in the crowded MCB market due to its exceptional reliability and robust construction, hallmarks of Siemens' commitment to industrial-grade components. Its C-curve tripping characteristic is particularly advantageous for applications with moderate inrush currents, such as motors and transformers, providing sensitive overload protection without nuisance tripping. This differentiates it from B-curve breakers, which are more suited for purely resistive loads. The 6kA breaking capacity ensures it can safely interrupt fault currents encountered in typical residential and commercial distribution boards, offering a high level of safety and compliance with international standards like IEC/EN 60898-1 and IEC/EN 60947-2. This combination of precise protection and high fault current handling positions the 5SY6 series as a dependable choice for professionals seeking long-term, stable electrical system performance.


Key Application Scenarios


This Siemens MCB is extensively utilized in distribution boards for residential, commercial, and light industrial settings where precise overcurrent protection is paramount. Its C-curve characteristic makes it ideal for protecting circuits feeding inductive loads like small motors in HVAC systems, pumps, and fans, as well as lighting circuits prone to inrush currents. Applications also extend to control panels, machine tool wiring, and supplementary protection for sensitive electronic equipment where consistent power delivery is critical. The 1P configuration is well-suited for single-phase circuits, common in most power distribution networks, ensuring targeted protection for individual lines and preventing cascading failures.


Practical System Integration Guidance


Integrating the Siemens 5SY6106-7CC into an electrical system is straightforward due to its standard DIN rail mounting (35mm) and readily accessible screw terminals. Proper installation requires ensuring the breaker is de-energized before wiring. The line (input) connection should be made to the top terminal, and the load (output) to the bottom terminal, following the clear markings on the device. For optimal performance and safety, it's crucial to use appropriately sized conductors that match the 6A rating and the terminal connection capabilities. Ensure all connections are securely tightened to prevent resistive losses and potential overheating. The breaker should be installed in an environment within its specified ambient temperature range (-25°C to +45°C) and within an enclosure providing at least IP40 protection to prevent dust and foreign object ingress.


Operation and Risk Mitigation


The Siemens 5SY6106-7CC operates by continuously monitoring the current flowing through its circuit. If the current exceeds a predetermined safe level due to an overload or a short circuit, a thermal or magnetic tripping mechanism is activated, rapidly interrupting the power flow. This prevents overheating of wiring, damage to connected equipment, and potential fire hazards. To mitigate risks during operation, always ensure the breaker is rated for the specific load and voltage of the circuit it protects. Never bypass or disable the tripping mechanism. If the breaker trips frequently, it indicates an underlying issue, such as an overloaded circuit, a short circuit, or a faulty appliance, which requires immediate investigation by a qualified electrician rather than repeatedly resetting the breaker.


Scalability & Long-Term Value


The Siemens 5SY6106-7CC, as part of the broader Siemens electrical product ecosystem, offers inherent long-term value through compatibility and reliability. While this specific MCB is designed for direct circuit protection, its integration within standard distribution panels allows for straightforward system expansion or modification. Upgrades to higher-rated breakers or additional poles can be accommodated within the same mounting infrastructure, provided the overall system capacity and wiring support such changes. Siemens' commitment to quality ensures a long operational lifespan, reducing the need for premature replacements. Furthermore, adherence to established electrical codes and standards means that installations using this breaker remain compliant, facilitating future inspections and integration with evolving smart grid technologies or IIoT solutions that often rely on well-protected and monitored circuits.


Frequently Asked Questions (FAQs)


What is the primary function of the Siemens 5SY6106-7CC circuit breaker?

This device acts as a Miniature Circuit Breaker (MCB). It provides overcurrent protection. Its main role is to safeguard electrical circuits.


It automatically trips to interrupt power flow. This occurs during overload or short circuit conditions. This prevents damage to equipment and wiring. It also mitigates fire risks.


The Siemens 5SY6106-7CC protects single-phase lines. It is rated for 6 Amps. Its C-curve characteristic is suited for inductive loads.


Can the Siemens 5SY6106-7CC be used for motor protection?

Yes, this MCB is suitable for motor protection. Its C-curve tripping characteristic is ideal for this purpose. It can handle moderate inrush currents of motors.


Inductive loads like motors draw higher current upon startup. The C-curve allows for this surge. It prevents nuisance tripping during motor energization.


However, for continuous motor protection with high starting currents, specific motor protection relays or breakers may be considered. Always consult application guidelines.


What does the 'C' in 5SY6106-7CC signify?

The 'C' denotes the tripping curve type. This is a C-curve MCB. It is designed for inductive and mixed loads.


C-curve breakers trip between 5 to 10 times the rated current. This makes them suitable for applications with moderate inrush currents. Examples include motors, transformers, and fluorescent lighting.


It differentiates from B-curve (1 to 5 times) for resistive loads, and D-curve (10 to 20 times) for very high inrush currents.


What is the breaking capacity of this circuit breaker?

The Siemens 5SY6106-7CC has a breaking capacity of 6 kA. This refers to its ability to safely interrupt fault currents. It complies with IEC/EN 60898-1 standards.


A 6 kA rating means it can interrupt a fault current of up to 6,000 Amperes. This is sufficient for most standard residential and commercial distribution systems. It ensures safety during severe short circuits.


Ensuring the breaking capacity matches the system's prospective fault current is vital. This prevents catastrophic failure of the MCB during a fault.


How do I install the Siemens 5SY6106-7CC?

Installation requires mounting it on a standard 35mm DIN rail. Ensure the power supply to the circuit is de-energized for safety. Connect the line conductor to the upper terminal.


Connect the load conductor to the lower terminal. Ensure wires are securely fastened in the screw terminals. Use appropriate cable cross-sections for the 6A rating.


The breaker should be installed in a suitable enclosure. This protects it from dust and physical damage, offering IP40 protection.


What is the voltage rating for this circuit breaker?

The Siemens 5SY6106-7CC has a voltage rating of 230/400V AC. This is a standard rating for single-phase and three-phase systems. It is suitable for typical power distribution voltages.


It can be used in single-phase (230V) circuits, indicated by the 1P designation. It can also be part of a three-phase system rated up to 400V. Always confirm system voltage before installation.


Using a breaker with an incorrect voltage rating can lead to malfunction, damage, or fire. Always verify compatibility with your electrical system.


What is the operating temperature range for the 5SY6106-7CC?

The operating ambient temperature range for this MCB is -25°C to +45°C. This range ensures reliable performance under various environmental conditions. It is suitable for most indoor installations.


Exceeding these temperature limits can affect the breaker's performance. It may lead to premature tripping or reduced lifespan. Ensure adequate ventilation around the breaker.


For extremely high ambient temperatures, derating or specialized equipment might be necessary. Always check manufacturer specifications for challenging environments.


What troubleshooting steps should I take if the breaker trips?

If the breaker trips, first de-energize the circuit completely. Identify the cause: overload or short circuit. Check for damaged appliances or wiring.


Reset the breaker only after the fault condition is resolved. If it trips again immediately, there is likely a persistent short circuit. Do not repeatedly reset the breaker.


If the cause is not obvious, consult a qualified electrician. They can diagnose complex issues and ensure safe repairs.


Is the Siemens 5SY6106-7CC compliant with international standards?

Yes, this MCB is compliant with major international standards. It meets IEC/EN 60898-1 and IEC/EN 60947-2 requirements. These are key safety and performance benchmarks.


Compliance ensures the breaker has been rigorously tested. It guarantees reliability and safety for its intended applications. It is approved for use in many global markets.


Adherence to these standards simplifies system design and certification processes for installers and end-users.


Where can I purchase the Siemens 5SY6106-7CC?

This product is available from authorized Siemens distributors and electrical supply wholesalers. Online industrial automation and electrical component retailers also stock it.


It is advisable to purchase from reputable suppliers to ensure genuine Siemens quality. Check product listings for availability and pricing.


For large projects, direct contact with Siemens sales representatives or authorized distributors is recommended. They can provide technical support and bulk order information.