Siemens 5SY6502-8CC Motor Protection Circuit Breaker Switch 1P+N 2A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SY6502-8CC
  • HS: 85362030
Availability:In Stock
$17.21
zhongpingtech

The Siemens 5SY6502-8CC is a 1-pole plus neutral (1P+N) motor protection circuit breaker switch with a rated current of 2A, engineered for robust and reliable protection of electrical circuits and motors in industrial and commercial applications. Its core advantages lie in its compact design, high breaking capacity, and precise thermal and magnetic tripping mechanisms, ensuring optimal safety and operational continuity. Key technical parameters include a rated voltage of 400V AC, a tripping characteristic of C, and an ambient temperature range of -25°C to +45°C, making it suitable for demanding environments.


Product Specifications


| Feature                   | Specification                                  |

| :------------------------ | :--------------------------------------------- |

| Product Type              | Motor Protection Circuit Breaker (MPCB)        |

| Manufacturer              | Siemens                                        |

| Model Number              | 5SY6502-8CC                                    |

| Pole Configuration        | 1P+N (1 Pole + Neutral)                        |

| Rated Current (In)        | 2A                                             |

| Rated Voltage (Ue)        | 400V AC                                        |

| Tripping Characteristic   | C                                              |

| Breaking Capacity (Icn)   | 6 kA                                           |

| Frequency                 | 50/60 Hz                                       |

| Ambient Temperature Range | -25°C to +45°C                                 |

| Terminal Type             | Screw Terminals                                |

| Mounting Type             | DIN Rail                                       |

| Protection Class          | IP20                                           |

| Compliance                | IEC/EN 60947-2, IEC/EN 60898-1                 |


Core Features & Market Positioning


The Siemens 5SY6502-8CC distinguishes itself through its advanced thermal-overload and short-circuit protection, safeguarding motors from damage due to excessive current or abrupt fault conditions. Its C-curve tripping characteristic is specifically designed to handle the inrush currents typical of motor startups without nuisance tripping, while still providing rapid response to short circuits. This combination positions the 5SY6502-8CC as a superior choice for applications where reliable motor control and protection are paramount, offering a robust alternative to traditional fuse-based systems and providing enhanced safety and operational efficiency.


Key Application Scenarios


This motor protection circuit breaker is ideally suited for protecting single-phase motors, pumps, fans, and other inductive loads commonly found in building automation, HVAC systems, and light industrial machinery. Its 2A rating and 1P+N configuration make it perfect for smaller motor applications where precise overcurrent protection is required. Users often search for solutions to protect specific motor types, and the 5SY6502-8CC directly addresses this need by offering dependable safeguarding against thermal and magnetic fault events.


Practical System Integration Guidance


Integrating the Siemens 5SY6502-8CC into existing electrical panels is straightforward due to its standard DIN rail mounting and screw terminal connections. Proper wiring involves connecting the phase and neutral conductors to the appropriate input terminals and the load to the output terminals. It is crucial to ensure that the rated voltage and current of the connected circuit do not exceed the breaker's specifications. For systems requiring advanced control or monitoring, the 5SY6502-8CC can be part of a larger Siemens industrial control system, though direct communication protocols are not a primary feature of this specific device.


Operation and Risk Mitigation


The Siemens 5SY6502-8CC operates by monitoring the current flowing through its internal bimetallic strip for thermal overloads and an electromagnetic coil for short circuits. Upon detecting a fault condition exceeding its set thresholds, the breaker instantly trips, interrupting the circuit and preventing damage to the motor or wiring. Risk mitigation is inherent in its design; however, users must ensure correct installation and adherence to local electrical codes. Incorrect sizing or wiring can lead to premature tripping or, more critically, failure to trip during a fault, potentially causing equipment damage or fire hazards.


Scalability & Long-Term Value


While the 5SY6502-8CC is a standalone protective device, its value lies in its reliability and compatibility with the broader Siemens industrial automation portfolio. It integrates seamlessly into standard electrical distribution systems, offering a dependable protective layer for motor circuits. For increased scalability or advanced functionalities like remote monitoring or control, it can be incorporated into larger systems managed by Siemens PLCs or industrial PCs. The long-term value is enhanced by Siemens' reputation for durable, high-quality components designed for extended operational life in demanding industrial environments.


Frequently Asked Questions (FAQs)


1. What is the purpose of a Siemens 5SY6502-8CC?

This device functions as a motor protection circuit breaker. It offers both overload and short-circuit protection for electrical circuits and motors.


Its primary role is to prevent damage to equipment and wiring. It ensures operational safety by interrupting power during fault conditions.


The 5SY6502-8CC is designed to safeguard motors from thermal stress and sudden electrical surges. This enhances the lifespan of connected machinery.


2. Can I use the Siemens 5SY6502-8CC for general lighting circuits?

While technically possible, it's not the intended application. It is specifically designed for motor loads.


Motor protection breakers have specific tripping curves (like 'C') suited for motor inrush currents. General lighting might not need this feature.


Using it for lighting may lead to nuisance tripping or inefficient protection. Standard miniature circuit breakers (MCBs) are better suited for lighting.


3. What does the 'C' in Siemens 5SY6502-8CC refer to?

The 'C' denotes the tripping characteristic of the circuit breaker. It indicates how quickly the breaker trips under overload conditions.


A Type C breaker is designed to tolerate higher inrush currents, typically from motors. This prevents unwanted tripping during motor startup.


It provides protection against short circuits and moderate overloads, making it suitable for inductive loads like motors.


4. How do I wire the Siemens 5SY6502-8CC 1P+N breaker?

Connect the incoming phase and neutral wires to the designated input terminals. Ensure correct polarity for the phase conductor.


The outgoing load wires (phase and neutral) are then connected to the output terminals. Double-check all connections for tightness.


Always disconnect power before wiring and follow local electrical codes for safe installation practices.


5. What is the breaking capacity of the Siemens 5SY6502-8CC?

The Siemens 5SY6502-8CC has a breaking capacity of 6 kA. This is the maximum fault current it can safely interrupt.


A higher breaking capacity ensures greater safety in the event of a severe short circuit. It prevents the breaker from being destroyed by the fault current.


This 6 kA rating is suitable for many residential, commercial, and light industrial applications. Always ensure it meets your specific installation's fault level requirements.


6. What ambient temperature range is the Siemens 5SY6502-8CC rated for?

The breaker is designed to operate within an ambient temperature range of -25°C to +45°C. This ensures reliable performance in various environments.


Operating outside this range can affect the breaker's tripping characteristics and lifespan. Extreme cold or heat can compromise its protective function.


Ensure adequate ventilation around the installed breaker to maintain the specified operating temperature.


7. Is the Siemens 5SY6502-8CC compatible with other brands of electrical components?

Siemens components are designed for robust integration within their own systems. Compatibility with other brands can vary.


This specific breaker uses standard DIN rail mounting and terminal types, which are industry standards. This increases the likelihood of physical compatibility.


However, for optimal performance and guaranteed safety, it is always recommended to use components from the same manufacturer or verify compatibility with the respective manufacturers.


8. What does 1P+N configuration mean for this breaker?

1P+N signifies a single-pole plus neutral configuration. It protects one phase conductor and switches the neutral conductor simultaneously.


This is crucial for certain safety standards and applications where it's necessary to completely isolate both the live and neutral lines. It ensures a more complete disconnection.


It is often used in systems where the neutral conductor carries current and needs to be switched along with the phase for full isolation.


9. How does the thermal overload protection work in this breaker?

The breaker contains a bimetallic strip that heats up with the current flow. If the current is consistently high, the strip bends and triggers the trip mechanism.


This slow-acting protection is designed to prevent damage from sustained overcurrents that are not severe enough for an instantaneous short-circuit trip. It protects against overheating.


The tripping point is adjustable or set according to the breaker's rating to protect specific motor windings from damage due to prolonged operation at high loads.


10. What are the benefits of using a motor protection circuit breaker over a standard MCB?

MPCBs like the 5SY6502-8CC offer integrated thermal and magnetic trip units. Standard MCBs typically only provide short-circuit and basic overload protection.


Motor protection breakers are specifically calibrated for motor starting currents, reducing nuisance tripping. They offer more precise protection against motor-specific faults.


The combined functionality reduces the need for separate overload relays and fuses, simplifying installation and reducing costs. They provide a more comprehensive protection solution for motors.

Menu