Siemens 5SY6204-8CC Protection Circuit Breaker for Electrical Systems 2P 4A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SY6204-8CC
  • HS: 85362030
Availability:In Stock
$17.35
zhongpingtech

The Siemens 5SY6204-8CC is a robust 2-pole, 4-ampere Miniature Circuit Breaker (MCB) engineered for reliable protection of electrical systems. This device is distinguished by its high breaking capacity, quick tripping mechanism, and compliance with stringent international safety standards, making it a cornerstone for electrical infrastructure in commercial, industrial, and residential settings. Its compact design and user-friendly installation features further enhance its appeal to engineers and electricians seeking dependable circuit protection.


Product Specifications


| Feature             | Specification                                |

| :------------------ | :------------------------------------------- |

| Product Type        | Miniature Circuit Breaker (MCB)              |

| Manufacturer        | Siemens                                      |

| Series              | 5SY6                                         |

| Number of Poles     | 2                                            |

| Rated Current       | 4 A                                          |

| Tripping Curve      | C                                            |

| Rated Voltage       | 400 V AC (IEC)                               |

| Breaking Capacity   | 6 kA (IEC 60898-1)                           |

| Frequency           | 50/60 Hz                                     |

| Protection Class    | IP20                                         |

| Operating Temperature | -25 °C to +45 °C                             |

| Mounting Type       | DIN Rail (35 mm)                             |

| Terminal Type       | Cage clamp terminal                          |

| Color               | White                                        |

| Compliance          | IEC/EN 60898-1, IEC/EN 60947-2               |


Core Features & Market Positioning


The Siemens 5SY6204-8CC MCB excels in providing superior overcurrent and short-circuit protection due to its high breaking capacity of 6 kA, ensuring safety even in fault-intensive environments. Its Type C tripping characteristic is ideal for circuits with moderate inductive loads, offering enhanced protection against nuisance tripping while still safeguarding against rapid current surges. This positioning makes it a preferred choice for applications where a balance between sensitivity and robustness is required, differentiating it from MCBs with less capable tripping curves or lower breaking capacities. Siemens' reputation for quality and reliability further solidifies the 5SY6 series' market standing as a dependable solution for critical electrical installations.


Key Application Scenarios


This 4A, 2-pole MCB is extensively deployed in standard distribution boards for protecting lighting circuits, socket outlets, and small motor loads in residential and commercial buildings. Its C-curve is particularly well-suited for applications with inrush currents, such as fluorescent lighting with magnetic ballasts or small air conditioning units, where brief current surges are common but do not indicate a fault condition. In industrial settings, the 5SY6204-8CC serves as a crucial component in control panels and machine wiring, offering precise protection for low-power control circuits and auxiliary equipment, ensuring operational continuity and preventing damage from electrical anomalies.


Practical System Integration Guidance


Integrating the Siemens 5SY6204-8CC into existing electrical systems is straightforward, leveraging its standard 35mm DIN rail mounting capability for quick installation in distribution cabinets. The cage clamp terminals facilitate secure and efficient wire connections, accommodating solid and stranded conductors up to a specified gauge, simplifying wiring procedures for electricians. Proper commissioning involves ensuring correct pole isolation and verifying that the breaker's rated current and tripping characteristics align with the protected circuit's load requirements to prevent premature tripping or inadequate protection.


Operation and Risk Mitigation


The primary function of the Siemens 5SY6204-8CC is to automatically interrupt the electrical circuit when an overcurrent or short circuit is detected, thereby preventing overheating, fire hazards, and damage to connected equipment. To mitigate risks, it is imperative to adhere to the rated voltage and current specifications and ensure the ambient temperature remains within the operational limits. Regular visual inspection for any signs of damage or wear, along with periodic testing of its tripping mechanism, can further enhance operational safety and reliability.


Scalability & Long-Term Value


The 5SY6 series, including the 5SY6204-8CC, offers inherent scalability due to its compatibility with a wide range of Siemens' modular DIN rail components, allowing for easy expansion of protection systems within the same distribution board. Its robust construction and adherence to international standards like IEC/EN 60898-1 and IEC/EN 60947-2 ensure long-term operational stability and a reduced likelihood of premature failure, contributing to the overall cost-effectiveness of electrical installations. While direct integration with IIoT platforms might require additional monitoring devices, the inherent reliability of the 5SY6 series provides a solid foundation for smart grid-ready electrical infrastructure.


---


Frequently Asked Questions (FAQs)


What is the primary function of a Siemens 5SY6204-8CC circuit breaker?

Its main role is to protect electrical circuits from damage caused by overloads and short circuits. It automatically interrupts the power flow when current levels become dangerously high. This prevents overheating of wires and connected equipment.


This MCB acts as an essential safety device, safeguarding against electrical fires and equipment failures. It ensures the integrity and longevity of the electrical installation. Its tripping mechanism is designed for rapid response to fault conditions.


The 5SY6204-8CC provides automatic protection, enhancing overall electrical system safety and reliability. It is a critical component for preventing costly damages and potential hazards in various applications.


What does the "C" in 5SY6204-8CC tripping curve signify?

The "C" denotes a Type C tripping curve, suitable for circuits with moderate inrush currents. This means it tolerates brief, higher-than-normal current surges without tripping. It is designed for inductive loads like motors or lighting with ballasts.


Type C breakers offer a balance between sensitivity to faults and immunity to nuisance tripping from common inrush currents. This characteristic makes them versatile for many commercial and industrial applications. They trip between 5 to 10 times the rated current.


Compared to Type B (for resistive loads) or Type D (for very high inrush), Type C provides broader protection. It’s a common choice for general-purpose power circuits where inductive loads are present.


How does the 6 kA breaking capacity of the 5SY6204-8CC impact its application?

A 6 kA breaking capacity indicates the maximum fault current the breaker can safely interrupt without being damaged. This rating is crucial for ensuring safety in environments with higher potential fault currents. It meets the requirements for most standard residential and commercial distribution systems.


This higher breaking capacity provides an enhanced safety margin in installations where short-circuit levels might exceed standard residential expectations. It ensures the device can safely handle significant fault conditions, preventing cascading failures.


For systems where the prospective short-circuit current is known to be below 6 kA, the 5SY6204-8CC offers robust and reliable protection. It is important to verify the installation's fault current levels against this specification.


Can the Siemens 5SY6204-8CC be used for DC applications?

The Siemens 5SY6204-8CC is primarily designed and rated for AC (Alternating Current) electrical systems. Its performance characteristics and safety certifications are based on AC operation. Using it in DC circuits can lead to unpredictable behavior and safety risks.


For DC applications, it is essential to use circuit breakers specifically designed and rated for Direct Current. DC circuits have different arc-quenching requirements than AC circuits, which the standard AC MCB cannot safely handle.


Consulting the product's technical documentation or contacting Siemens support is recommended to ensure correct application and safety. Always use components certified for the specific voltage and current type of your system.


What are the key advantages of the 2-pole design of this circuit breaker?

The 2-pole design ensures that both the live and neutral conductors of a circuit are simultaneously disconnected during a fault. This provides a higher level of safety by ensuring complete isolation of the circuit. It's particularly important in systems where a neutral fault could still pose a hazard.


Simultaneous breaking of live and neutral conductors offers enhanced protection against electric shock. It guarantees that no voltage potential remains on the circuit after tripping, even if the neutral wire is inadvertently connected to earth.


This double-pole switching is a standard safety feature for many circuits, especially in modern installations. It offers more comprehensive protection compared to single-pole breakers that only switch the live conductor.


What is the significance of the "4A" rating for this circuit breaker?

The "4A" specifies the rated current, meaning the breaker is designed to continuously carry up to 4 amperes of electrical current without tripping under normal operating conditions. It is crucial for protecting circuits with loads that do not exceed this current limit. Exceeding this rating for extended periods will cause the breaker to trip.


This low amperage rating makes the 5SY6204-8CC ideal for protecting sensitive low-power circuits. Examples include certain types of control circuits, small appliances, or dedicated lighting circuits where high current draw is not expected.


Selecting the correct rated current is vital for effective protection. An underrated breaker will trip too often, while an over-rated one will not provide adequate protection against overloads.


How should the Siemens 5SY6204-8CC be installed on a DIN rail?

Installation on a 35mm standard DIN rail is straightforward. The breaker has a clip mechanism at the back that engages with the rail. Ensure the rail is securely mounted and the breaker is firmly attached by pressing it onto the rail until it clicks into place.


Before mounting, always ensure the main power supply to the distribution board is switched off and de-energized to prevent electrical shock. Connect the wires to the appropriate terminals (line and neutral) after the breaker is secured to the rail.


Verify that the breaker is oriented correctly, typically with the ON/OFF lever facing outwards and upwards when in the ON position. Proper installation ensures reliable operation and adherence to electrical safety standards.


What types of loads are best protected by a Type C tripping curve MCB?

Type C MCBs are ideal for circuits powering equipment that exhibits moderate inductive loads or inrush currents. This includes fluorescent lighting systems, small to medium-sized electric motors, and some types of air conditioning units. These loads briefly draw more current upon startup.


The C-curve provides a balance, allowing for these typical startup surges without causing nuisance tripping, while still offering sensitive protection against sustained overloads and short circuits. It is a versatile choice for mixed-load applications.


This tripping characteristic distinguishes it from Type B (for purely resistive loads) and Type D (for very high inrush currents like welding equipment). It's a common specification for general-purpose power circuits in commercial and industrial settings.


What is the role of compliance with IEC/EN 60898-1 and IEC/EN 60947-2 standards?

These standards define the safety and performance requirements for circuit breakers in residential, commercial, and industrial applications. Compliance ensures the 5SY6204-8CC meets rigorous international benchmarks for reliability, breaking capacity, and operational safety. This guarantees consistent and predictable protection.


Adhering to these IEC/EN standards means the breaker has undergone extensive testing to verify its ability to safely interrupt fault currents and protect electrical installations. It assures users that the product is safe for its intended use and will perform as expected in fault scenarios.


Manufacturers like Siemens design and test their products to meet these global standards, facilitating international trade and ensuring a baseline level of electrical safety across different regions. It simplifies selection for engineers and installers worldwide.


Where can I find replacement parts or accessories for the Siemens 5SY6204-8CC?

Replacement parts and compatible accessories, such as busbars or auxiliary switches, are typically available through authorized Siemens distributors and electrical wholesalers. These channels ensure you receive genuine Siemens components that are guaranteed to be compatible. Always specify the exact product number when ordering.


For accessories like auxiliary contacts or alarm switches, ensure they are designed for use with the Siemens 5SY series MCBs. These additions can enhance monitoring and control capabilities of the circuit breaker system. Check product compatibility charts or consult distributor catalogs.


If you need further assistance or are unsure about specific parts, contacting Siemens technical support or your regional sales representative is advisable. They can provide expert guidance and direct you to the correct sourcing channels for your needs.

Menu