SIEMENS LMO24.111C2 Program Controller LMO24 Standard Burner

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:LMO24.111C2
  • HS: 8416900000
Availability:In Stock
$105.88
zhongpingtech

The SIEMENS LMO24.111C2 Program Controller LMO24 Standard Burner is a crucial component for controlling industrial combustion processes, offering reliability and precise operation. This program controller excels with its integrated safety functions, wide operating temperature range, and straightforward integration into various burner management systems. Key technical parameters include a voltage supply of 200-240 V AC, a frequency of 50/60 Hz, and an operating temperature range of -20 to +60 °C. Its compact design and robust construction ensure dependable performance in demanding industrial environments.


| Parameter           | Specification                     |

| :------------------ | :-------------------------------- |

| Product Type        | Standard Burner Program Controller |

| Model Number        | LMO24.111C2                       |

| Manufacturer        | Siemens                             |

| Voltage Supply      | 200-240 V AC                      |

| Frequency           | 50/60 Hz                            |

| Operating Temp.     | -20 to +60 °C                     |

| Protection Class    | IP40                              |

| Dimensions (W x H x D) | 144 x 144 x 138 mm               |

| Application         | Single-stage gas burners          |


Core Features & Market Positioning


The SIEMENS LMO24.111C2 stands out in the burner control market due to its inherent safety and operational efficiency. It is engineered for single-stage gas burners, providing reliable ignition and flame monitoring. The unit's design prioritizes user safety with built-in lockout mechanisms that prevent burner restart in case of flame failure or during system malfunctions. This robust approach positions the LMO24.111C2 as a trusted choice for applications where consistent and safe combustion is paramount, distinguishing it from less integrated or less safety-conscious alternatives. Its compatibility with various burner types and ease of replacement for older LMO series units further enhance its market appeal.


Key Application Scenarios


This program controller finds extensive use in commercial and industrial heating applications. It is the preferred choice for controlling single-stage gas burners in boilers, furnaces, and process heaters. Industries such as HVAC, food processing, and manufacturing commonly rely on the SIEMENS LMO24.111C2 for maintaining precise temperature control and ensuring safe fuel combustion. Its adaptability makes it suitable for retrofitting older systems or for new installations where a reliable and straightforward burner management solution is required, directly addressing user needs for dependable heating and process stability.


Practical System Integration Guidance


Integrating the SIEMENS LMO24.111C2 into an existing system is a streamlined process, facilitating rapid deployment. The unit utilizes a standard 12-pin base, simplifying electrical connections and replacement. Proper wiring according to the provided wiring diagrams is critical for ensuring correct function and safety. Typically, connections involve power supply, burner ignition, flame signal input (e.g., from a flame rod or UV scanner), and actuator controls. Commissioning involves verifying the sequence of operations, including pre-purging, ignition, and main flame establishment, along with fail-safe shutdown procedures. Attention to the specific burner manufacturer's guidelines alongside the LMO24.111C2 manual is essential for optimal performance.


Operation and Risk Mitigation


Safe operation of the SIEMENS LMO24.111C2 depends on adherence to installation and maintenance protocols. The controller initiates a pre-ignition sequence, followed by ignition and flame establishment. If a flame is detected within the specified time, the program proceeds to full operation. Flame failure triggers an immediate shutdown and lockout, requiring a manual reset to prevent hazardous conditions. Common troubleshooting involves checking power supply, flame signal integrity, and actuator functionality. Error codes, if indicated by specific LED patterns on the unit, often point to issues like short or open flame sensor circuits, or timing-related problems during the combustion cycle, necessitating careful diagnosis.


Scalability & Long-Term Value


While the SIEMENS LMO24.111C2 is designed for standard, single-stage burner applications, its long-term value is derived from Siemens' commitment to industrial automation standards. Its compatibility with a broad range of Siemens burner components and control systems ensures that it can be integrated into larger, more sophisticated automation platforms if future upgrades are considered. For systems requiring multi-stage or modulating burner control, this unit serves as a foundational element or a component within a broader Siemens control architecture. The inherent reliability and Siemens' established support network contribute to the long-term operational viability and cost-effectiveness of systems employing this controller.


Frequently Asked Questions


What is the primary function of the SIEMENS LMO24.111C2?

The SIEMENS LMO24.111C2 acts as a safety and control device for single-stage gas burners. It meticulously manages the entire burner sequence, from ignition to flame stabilization. Its core purpose is to ensure safe and efficient combustion within industrial heating applications.


This controller is specifically designed to monitor the flame and shut down the burner instantly if the flame is lost. This safety interlock prevents fuel accumulation and potential hazards. The program controller dictates the timing of all operational phases, including pre-purging, ignition trial, and post-purging.


Its application spans various equipment like boilers, furnaces, and process heaters where precise control over gas combustion is essential. The unit’s design emphasizes reliability and adherence to stringent safety standards.


How do I reset a locked-out SIEMENS LMO24.111C2?

To reset a locked-out SIEMENS LMO24.111C2, first identify the cause of the lockout. Typically, a lockout occurs due to flame failure or a system malfunction during operation. Ensure the burner system has been safely shut down and the issue causing the fault has been addressed.


Locate the reset button on the program controller unit. This is usually a small, often red, push-button. Press and hold the reset button for a specified duration, typically a few seconds, as indicated in the product manual.


After pressing the reset button, observe the controller's indicator lights. If the reset is successful and the underlying fault is resolved, the controller should indicate readiness for a new startup sequence. If it immediately re-locks out, further investigation into the specific fault is required.


What are the typical voltage and frequency requirements for the LMO24.111C2?

The SIEMENS LMO24.111C2 program controller operates on a standard mains voltage supply. It is designed to function reliably within a voltage range of 200 to 240 Volts AC. This common voltage range makes it compatible with most industrial power grids in many regions.


The controller is also designed to accommodate the standard industrial power frequencies. It can operate equally well with either a 50 Hz or a 60 Hz electrical supply. This dual-frequency capability provides flexibility for installation in diverse international locations.


Ensuring the incoming power matches these specifications is critical for the correct and safe operation of the LMO24.111C2. Incorrect voltage or frequency can lead to malfunction or damage to the unit. Always verify your power source before connecting the controller.