Delta DVP08XM211N 8-point Digital Input Output Mixed Module

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:DVP08XM211N
  • HS: 85371090
Availability:In Stock
$31.85
zhongpingtech

The Delta DVP08XM211N is an 8-point digital input/output mixed module designed for enhanced control and flexibility in industrial automation applications. This module boasts rapid response times, robust industrial-grade construction, and seamless integration capabilities, making it a cornerstone for efficient process management. Its compact design and versatile I/O configuration simplify panel space utilization and offer significant advantages in both new system designs and upgrades. Key technical parameters include an operating voltage of 24 VDC, a maximum input/output current of 0.5A per point, and an impressive response time of typically under 10ms for both input and output operations. This module supports a wide ambient operating temperature range, ensuring reliability in demanding industrial environments.


Product Specifications


| Feature                  | Specification                    |

| :----------------------- | :------------------------------- |

| Model                    | DVP08XM211N                      |

| Type                     | Digital Input/Output Mixed Module |

| Number of Points         | 8                                |

| Input Points             | 4                                |

| Output Points            | 4 (Transistor Sink Output)       |

| Input Voltage            | 24 VDC                           |

| Output Voltage           | 24 VDC                           |

| Max. Input/Output Current| 0.5A per point                   |

| Isolation                | Photocoupler                     |

| Response Time            | < 10ms (typical)                 |

| Operating Temperature    | 0°C to 50°C                      |

| Storage Temperature      | -20°C to 60°C                    |

| Dimensions (W x H x D)   | 35 x 90 x 60 mm                  |


Core Features & Market Positioning


The Delta DVP08XM211N distinguishes itself through its cost-effectiveness and high-density I/O integration, a critical advantage in space-constrained control cabinets. Its transistor sink outputs offer a distinct benefit for applications requiring faster switching speeds and lower power consumption compared to relay outputs. This module is positioned as a highly reliable and versatile solution for small to medium-scale automation tasks, particularly within the Delta DVP series PLC ecosystem, where seamless compatibility and streamlined programming are paramount. Its robust design ensures longevity and consistent performance in harsh industrial settings, appealing to engineers prioritizing durability and operational stability.


Key Application Scenarios


Engineers frequently seek solutions for discrete control tasks in manufacturing, such as managing conveyor belts, actuating pneumatic cylinders, or monitoring limit switches. The DVP08XM211N excels in these scenarios, providing four digital inputs for sensor feedback and four digital outputs for actuator control within a single, compact unit. It is ideal for machine automation, packaging equipment, and material handling systems where precise, rapid digital signal processing is essential. Furthermore, its compatibility with Delta's broader PLC offerings makes it a go-to choice for integrated solutions in food and beverage processing, textiles, and general industrial machinery.


Practical System Integration Guidance


Integrating the Delta DVP08XM211N into a Delta PLC system is straightforward. Installation typically involves snapping the module onto a standard DIN rail within the PLC's chassis. Wiring requires connecting the 24 VDC power to the module's power terminals and then linking the digital inputs to sensors and the digital outputs to actuators or indicator lights, observing correct polarity. For programming, engineers utilize the Delta WPLSoft software, mapping the module's I/O points to the PLC's internal memory addresses for logical operations. For instance, a simple program could turn on an indicator light (output) when a proximity sensor (input) is triggered. Ensuring proper grounding and adherence to voltage ratings is crucial for system integrity.


Operation and Risk Mitigation


Safe operation of the Delta DVP08XM211N hinges on adhering to its electrical specifications and proper wiring practices. Overloading the output terminals beyond the 0.5A per point limit can lead to module failure. It is imperative to use appropriate wire gauges for the current load. Potential troubleshooting issues might include input signal intermittency, often resolved by checking sensor wiring and signal integrity, or output failures, which could stem from exceeding current limits or faulty wiring to the actuator. The module's internal circuitry provides some protection, but external fuses are recommended for robust circuit protection against short circuits. Referencing the Delta PLC user manual for specific fault code interpretations is vital for efficient diagnostics.


Scalability & Long-Term Value


The Delta DVP08XM211N offers significant long-term value through its integration with Delta's scalable automation platforms. It can be easily expanded by adding more DVP series modules to the same PLC base unit, allowing systems to grow as production demands increase. Its compatibility with existing Delta PLC controllers ensures that investments in automation infrastructure are protected, facilitating seamless upgrades and modifications. For those looking towards Industry 4.0 integration, Delta's platform supports communication protocols that enable this mixed I/O module to feed data into SCADA systems or IIoT platforms, providing valuable operational insights and enabling advanced analytics for process optimization.


Frequently Asked Questions


What is the maximum current capacity for each digital output on the Delta DVP08XM211N?

Each individual digital output on the Delta DVP08XM211N module is rated for a maximum current of 0.5 Amperes. Exceeding this limit can cause the output transistor to overheat or fail, leading to operational issues and potential module damage.


It is crucial to ensure that the connected load, such as a solenoid valve or relay coil, does not draw more than 0.5A. Always refer to the specifications of the connected device to confirm its current draw. Using external relays or contactors for higher current loads is a recommended practice to protect the module.


Proper wire sizing is also important; use appropriately gauged wires to handle the specified current without significant voltage drop or excessive heat generation. This ensures reliable power delivery to the connected actuator.


How do I wire the digital inputs for the Delta DVP08XM211N module?

To wire the digital inputs, connect your sensors (e.g., proximity switches, pushbuttons) to the input terminals of the DVP08XM211N. Ensure that the common terminal for the input section is connected to the 24 VDC positive or negative, depending on whether you are using a sourcing or sinking configuration, as per the module's manual.


For a sinking input configuration, which is common, the sensor's output signal will connect to the input point, and the common terminal will be connected to the 0V (negative) of the 24 VDC supply. When the sensor is activated, it pulls the input point towards 0V.


Always verify the wiring diagram provided in the Delta DVP08XM211N user manual for precise connection details. Incorrect wiring can lead to signal errors or damage to the module or connected sensors. Double-check polarity and ensure secure connections.


Can the Delta DVP08XM211N module be used with PLCs from other manufacturers?

While the DVP08XM211N is designed and optimized for Delta's own DVP series PLCs, it can potentially be interfaced with PLCs from other manufacturers. This integration would require careful consideration of voltage levels, signal types, and communication protocols.


You would need to ensure that the external PLC's output signals can drive the inputs of the DVP08XM211N (24 VDC) and that the DVP08XM211N's outputs (24 VDC transistor sink) are compatible with the input requirements of the external PLC. This often involves using interface relays or signal converters.


Direct integration is usually not plug-and-play. You will need to consult the technical documentation for both the DVP08XM211N and the third-party PLC to design a suitable interface circuit and programming logic. Compatibility is not guaranteed and may require significant engineering effort.


What is the typical response time for the digital I/O on this module?

The Delta DVP08XM211N module offers a fast response time, typically under 10 milliseconds for both its digital inputs and outputs. This rapid switching capability is crucial for high-speed automation applications where precise timing is essential.


This quick response allows the PLC to detect changes in input signals or actuate outputs with minimal delay, which is vital for applications like high-speed packaging machines, precise motion control, or critical safety interlocks. The consistent performance ensures reliable operation in dynamic industrial environments.


When evaluating the overall system response time, remember to also consider the PLC's scan time and the response time of the connected sensors and actuators. The module's <10ms specification refers to its internal processing and switching speed.


Is the Delta DVP08XM211N module isolated?

Yes, the Delta DVP08XM211N module features photocoupler isolation between the input/output circuits and the internal PLC logic. This isolation is a critical safety and reliability feature in industrial environments.


Photocoupler isolation prevents high voltages or electrical noise from the I/O side from damaging the sensitive internal electronics of the PLC. It also helps to prevent ground loops, which can cause erratic behavior and signal interference in complex systems.


This isolation ensures that the module can be safely used in applications with different voltage potentials or where electrical noise is a concern, enhancing the overall robustness and safety of your automation system.


What is the operating temperature range for the DVP08XM211N?

The Delta DVP08XM211N module is designed to operate reliably within an ambient temperature range of 0°C to 50°C (32°F to 122°F). This specification ensures its suitability for a wide variety of industrial environments.


It is important to ensure that the control panel where the module is installed is adequately ventilated to maintain temperatures within this specified range, especially in hot climates or densely packed enclosures. Excessive heat can negatively impact electronic component lifespan and performance.


For environments that may exceed this range, consider using industrial-grade enclosures with cooling systems or selecting alternative modules designed for extreme temperature operation. Always consult the product datasheet for precise operating conditions.


How many input and output points does the Delta DVP08XM211N have?

The Delta DVP08XM211N is an 8-point mixed digital module, featuring four digital inputs and four digital outputs. This configuration is ideal for applications requiring a balanced number of sensing and control points in a compact form factor.


The four digital inputs can be used to monitor the status of sensors, switches, or other digital devices. The four digital outputs, utilizing transistor sink technology, are suitable for controlling actuators like small motors, indicator lights, or relays with low power requirements.


This specific combination of inputs and outputs makes it a versatile choice for many basic automation tasks and machine control applications where a dedicated set of both input and output signals is needed.


What type of output does the Delta DVP08XM211N module use?

The Delta DVP08XM211N module utilizes transistor sink outputs. This means that when the output is turned ON, it effectively connects the load to the 0V (negative) side of the power supply.


Transistor sink outputs are known for their fast switching speeds, low power consumption, and long operational life compared to mechanical relays. They are well-suited for driving loads like indicator LEDs, small relays, or certain types of solenoids.


When wiring these outputs, ensure that the positive terminal of your load is connected to the 24 VDC supply, and the negative terminal is connected through the output point of the module. Always observe the maximum current rating of 0.5A per output.


Can this module be expanded with additional I/O modules?

Yes, the Delta DVP08XM211N is part of the Delta DVP series, which is designed for scalability. It can be easily expanded by adding more compatible DVP series I/O modules to the same PLC base unit.


This modularity allows you to tailor the system's I/O count precisely to your application's needs, starting with a basic configuration and adding modules as your automation requirements grow. This flexibility protects your initial investment and allows for future system upgrades.


You can connect multiple digital, analog, or special function modules to a single Delta DVP PLC, providing a robust and adaptable automation solution for a wide range of industrial processes.


What is the physical size of the Delta DVP08XM211N module?

The Delta DVP08XM211N module has compact dimensions of 35mm in width, 90mm in height, and 60mm in depth. This small footprint is advantageous for installations in space-constrained control panels and enclosures.


Its slim profile allows for high-density mounting on standard 35mm DIN rails, maximizing the use of available space within the electrical cabinet. This efficient design contributes to easier panel layout and maintenance.


The physical size is a key consideration for system integrators and panel builders, ensuring that the module can be seamlessly incorporated into various machine and control system designs without occupying excessive room.

Menu