The DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX is a robust 4kW, 480V three-phase automation inverter engineered for demanding industrial applications. This variable frequency drive (VFD) excels in optimizing motor control for enhanced efficiency, precise performance, and reduced operational costs. Its core advantages lie in its advanced control algorithms, extensive programmability, and rugged construction designed for harsh environments. Key technical parameters include a 4kW power rating, 480V three-phase input/output, and an IP20 enclosure rating for general industrial use. The integrated safety features and compatibility with various industrial communication protocols further solidify its position as a leading solution for automation challenges.
DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX: Product Specifications
| Parameter | Specification |
| :-------------------- | :------------------------------------------ |
| Model Number | FC-360H4K0T4E20H2BXCDXXSXXXXA0BX |
| Power Rating | 4kW |
| Voltage | 480V |
| Phase | Three-Phase |
| Enclosure Class | IP20 |
| Series | VLT® AutomationDrive FC 360 |
| Output Current (Normal) | 9.1 A |
| Output Current (Heavy) | 8.2 A |
| Approvals | CE, UL, cUL, EAC, RCM, DNV |
| Dimensions (H x W x D) | 350 x 202 x 210 mm |
| Weight | 9.6 kg |
Core Features & Market Positioning
The DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX differentiates itself through its advanced VLT® Energy-Saving features, offering significant power factor correction and optimized motor performance to reduce energy consumption. Its robust design ensures reliability in challenging industrial settings, a critical factor for minimizing downtime and maintenance costs. The FC 360 series is recognized for its user-friendly interface and straightforward commissioning, making it accessible for a wide range of technical expertise. This VFD is positioned as a cost-effective yet high-performance solution for applications requiring precise motor speed and torque control. Its integration capabilities with various automation systems further enhance its market appeal.
Key Application Scenarios
This 4kW, 480V three-phase inverter is exceptionally suited for a diverse array of industrial applications. Common uses include pump and fan control in HVAC systems, where precise speed regulation translates to significant energy savings and improved system stability. It is also widely deployed in conveyor systems, mixers, extruders, and general machinery where variable speed and torque control are paramount for process optimization and product quality. The inherent flexibility of the DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX allows it to be adapted for demanding applications in food and beverage, water treatment, and manufacturing sectors.
Practical System Integration Guidance
Integrating the DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX into existing systems is facilitated by its flexible configuration options and comprehensive documentation. Ensure proper power supply wiring to the input terminals, adhering strictly to the voltage and phase requirements (480V, three-phase). Motor connections should be made to the output terminals, using shielded cables where necessary to mitigate electrical noise. Programming the VFD for specific applications involves configuring parameters such as motor data, ramp times, and control modes via the integrated keypad or through serial communication. Basic commissioning typically involves a motor auto-tune function to optimize performance.
Operation and Risk Mitigation
Safe operation of the DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX mandates adherence to all electrical safety standards and local regulations. Always ensure the drive is de-energized and locked out before performing any wiring or maintenance. Proper grounding is critical to prevent electrical hazards and ensure the longevity of the equipment. Common error codes, such as overcurrent or overvoltage faults, typically indicate issues with motor load, power supply stability, or incorrect parameter settings. Referencing the product manual for specific fault code explanations and troubleshooting steps is essential for safe and effective problem resolution.
Scalability & Long-Term Value
The VLT® AutomationDrive FC 360 series, including the FC-360H4K0T4E20H2BXCDXXSXXXXA0BX, offers excellent scalability and long-term value. Its modular design and compatibility with various communication fieldbuses (e.g., Modbus, Profibus) enable seamless integration into larger automation architectures and IIoT platforms. This ensures that the inverter can adapt to evolving plant requirements and support future upgrades or expansions of the control system. The inherent energy-saving capabilities contribute to a reduced total cost of ownership over the product's lifespan, making it a strategic investment for businesses focused on operational efficiency and sustainability.
Frequently Asked Questions (FAQs)
What is the power rating of the DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX inverter?
This DANFOSS inverter is rated at 4 kilowatts (kW).
This specification is crucial for matching the drive to the motor's power requirements.
It ensures the drive can adequately supply power for optimal motor operation.
What voltage and phase configuration does this DANFOSS automation drive support?
The DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX operates on a 480V three-phase power supply.
This configuration is standard for many industrial applications in North America and other regions.
Verifying the supply voltage and phase is essential for safe and correct installation.
Can this inverter be used for pump and fan applications?
Yes, this inverter is highly suitable for variable speed pump and fan control.
Its advanced control algorithms optimize energy consumption in these applications.
Precise speed adjustment leads to improved system efficiency and reduced wear.
What is the enclosure rating of the FC-360H4K0T4E20H2BXCDXXSXXXXA0BX?
The enclosure rating for this specific model is IP20.
IP20 offers protection against solid objects larger than 12.5mm, but not against water.
This rating is suitable for clean, dry industrial environments.
How do I connect the motor to the DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX?
Connect the motor leads to the output terminals (U, V, W) of the inverter.
Use appropriately rated and shielded motor cables, especially in electrically noisy environments.
Ensure all connections are secure and follow wiring diagrams provided in the manual.
What are some common applications for this 4kW automation inverter?
This inverter is ideal for conveyor systems and general machinery.
It is also widely used in mixers, extruders, and various manufacturing processes.
Its versatility makes it suitable for diverse industrial automation tasks.
Does the DANFOSS FC-360H4K0T4E20H2BXCDXXSXXXXA0BX support communication protocols?
Yes, this inverter series supports various industrial communication protocols.
Commonly supported protocols include Modbus, with options for others via add-on modules.
This allows for seamless integration into SCADA and PLC systems.
What safety features are included in this DANFOSS VLT AutomationDrive?
The VLT AutomationDrive series typically includes integrated safety functions.
These can include safe torque off (STO) and other advanced safety features.
Always consult the product manual for a detailed list of safety functionalities.
How can I program this inverter for my specific application?
Programming is done via the integrated control panel or through a PC tool.
Key parameters to configure include motor data, control modes, and I/O settings.
Refer to the user manual for detailed parameter descriptions and programming guidance.
What is the expected lifespan of this industrial automation inverter?
With proper installation and maintenance, these inverters offer a long operational lifespan.
Factors like operating temperature and duty cycle influence longevity.
The robust design of Danfoss drives contributes to their durability and reliability.