Delta DVP32HP00R High-density 32-point Relay Output Module

stars
  • Availability:In Stock
  • Brand:DELTA
  • Model:DVP32HP00R
  • HS: 8538900000
Availability:In Stock
$169.05
zhongpingtech

The Delta DVP32HP00R high-density 32-point relay output module stands as a robust solution for demanding industrial automation tasks, offering exceptional reliability and expansive control capabilities. This module distinguishes itself through its high point count, compact design, and superior electrical specifications, making it a compelling choice for complex machinery and process control applications. Its core advantages lie in its dense I/O configuration, ensuring maximum control within a minimal footprint, and its high-performance relay outputs, capable of handling significant electrical loads with dependable switching. Crucial technical parameters include a power consumption of typically 5W, an operating temperature range from 0°C to 60°C, and an input/output voltage rating of 110-240VAC. With 32 relay outputs, the DVP32HP00R facilitates intricate control logic and the management of numerous actuators or indicators simultaneously, directly addressing the need for scalable and efficient automation in modern industrial environments.


Product Specifications


| Specification             | Value                       |

| :------------------------ | :-------------------------- |

| Model                     | DVP32HP00R                  |

| Output Type               | Relay Output                |

| Number of Points          | 32                          |

| Power Consumption         | Typically 5W                |

| Operating Temperature     | 0°C ~ 60°C (32°F ~ 140°F)   |

| Storage Temperature       | -20°C ~ 70°C (-4°F ~ 158°F) |

| Ambient Humidity          | 5% ~ 95% (non-condensing)   |

| Input/Output Voltage      | 110-240VAC                  |

| Isolation Voltage         | 1500VAC                     |

| Shock/Vibration Resistance| IEC60068-2-27, IEC60068-2-6 |

| Dimensions (W x H x D)    | 147 x 90 x 75 mm            |


Core Features & Market Positioning


The Delta DVP32HP00R excels in high-density I/O applications, a critical differentiator in environments where space is at a premium. Its robust relay outputs are engineered for longevity and high switching capacities, supporting inductive and resistive loads commonly found in industrial machinery, motor control, and power distribution systems. Positioned as a premium solution within Delta's DVP series, this module offers a significant advantage over lower-density alternatives by consolidating 32 output points into a single unit, simplifying wiring and reducing panel real estate. The module's inherent reliability and adherence to stringent industrial standards ensure consistent performance, a key factor for manufacturers seeking to minimize downtime and enhance operational efficiency.


Key Application Scenarios


This high-density relay output module finds its primary utility in complex machine automation, such as controlling multiple solenoids, contactors, or indicator lights on packaging machines, textile equipment, and assembly lines. It is also well-suited for process control applications requiring the management of numerous heating elements, pumps, or valves in industries like food and beverage, water treatment, and HVAC systems. Integrators leverage the DVP32HP00R for its ability to manage substantial output loads, making it ideal for direct control of low-voltage and line-voltage devices without the need for intermediate relays, thereby streamlining system design and reducing component count.


Practical System Integration Guidance


Integrating the Delta DVP32HP00R into a Delta PLC system is straightforward, primarily involving secure DIN rail mounting and proper wiring of the 32 relay output terminals. Each output terminal is clearly labeled, facilitating accurate connection to field devices. When wiring, ensure compliance with local electrical codes and best practices, particularly concerning insulation and grounding for AC power circuits. For programming, the DVP32HP00R integrates seamlessly with Delta's ISPSoft programming software, allowing users to map the 32 output points directly to PLC internal registers or memory bits for control logic execution. It's essential to verify the current and voltage ratings of the connected devices against the module's specifications to prevent overload and ensure safe operation.


Operation and Risk Mitigation


Safe operation of the Delta DVP32HP00R hinges on adhering to its specified voltage and current limits, and ensuring proper ventilation to maintain operating temperatures within the 0°C to 60°C range. Transient voltage suppression across relay contacts can be beneficial when switching inductive loads to prolong contact life and prevent arcing. In the event of a fault, common issues may include overloaded outputs, incorrect wiring, or external power supply problems. While the DVP32HP00R itself does not typically log specific error codes, system diagnostics within the PLC program should be configured to monitor output status and detect anomalies, such as a failure to energize or de-energize, which might indicate a faulty output relay or an issue with the connected load.


Scalability & Long-Term Value


The Delta DVP32HP00R offers significant long-term value through its compatibility with the broader Delta DVP series PLC platforms, allowing for straightforward expansion of control capabilities. Existing Delta installations can readily incorporate this module to increase output capacity without requiring a complete system overhaul. This modularity supports future-proofing by enabling system upgrades or modifications as automation requirements evolve. Furthermore, its integration into Delta's PLC ecosystem facilitates connectivity with human-machine interfaces (HMIs) and supervisory control systems, paving the way for enhanced data acquisition and IIoT integration, providing a scalable foundation for smart manufacturing initiatives.


Frequently Asked Questions


What is the maximum load current for each relay output on the Delta DVP32HP00R?

Each individual relay contact on the DVP32HP00R is typically rated for a maximum current of 2A. This rating is suitable for controlling a variety of devices, including small to medium-sized motors, solenoids, and indicator lamps. It is crucial not to exceed this 2A limit per output to ensure the longevity and reliability of the module's relays.


Exceeding the 2A limit can lead to premature contact wear or failure, potentially causing operational disruptions. Always consult the detailed datasheet for specific resistive, inductive, and lamp load current derating curves under different operating conditions to maintain optimal performance and safety standards.


Careful consideration of the inrush current for certain loads, like inductive coils, is also recommended. If a connected device's continuous or inrush current exceeds 2A, an intermediate relay or contactor controlled by the DVP32HP00R should be employed.


Can the Delta DVP32HP00R be used with AC and DC loads?

The Delta DVP32HP00R relay outputs are designed to switch both AC and DC loads, offering broad application flexibility. However, it is essential to respect the specified voltage and current limits for each type of load. For DC loads, particular attention should be paid to suppressing arcing, as DC circuits can be more challenging to break cleanly than AC circuits due to the lack of current zero crossings.


When switching DC loads, the maximum current rating per output may be lower than for AC loads, especially for inductive DC loads. Delta often provides specific guidelines or derating factors in their technical documentation for DC switching applications. Always verify these specifications to prevent relay damage and ensure reliable operation.


For AC loads, the module reliably switches standard line voltages up to 240VAC. The 2A rating applies to resistive AC loads. As with DC, inductive AC loads may require arc suppression or operate at reduced current ratings to ensure the best contact life and system stability.


How do I program the Delta DVP32HP00R module within a Delta PLC?

Programming the DVP32HP00R involves configuring the PLC's output addresses to correspond to the physical relay outputs of the module. Using Delta's ISPSoft software, you can assign logic conditions or instructions that trigger these output points. For instance, a coil instruction can be used to energize a specific output (e.g., Y0, Y1, ... Y31) when a certain condition in your ladder logic program is met.


You will typically map the 32 output points of the DVP32HP00R to the PLC's output image table or directly to physical output registers. The module functions as an extension of the PLC's native I/O, so standard output instructions within ISPSoft are applicable. Ensure correct base addressing if the module is part of an extended I/O configuration in your PLC project.


Crucially, your program logic should account for the state of each output, including setting default states upon PLC startup or during specific operational modes. Implementing fault detection routines to monitor the status of critical outputs can also enhance system reliability and aid in troubleshooting.


What are the dimensions and mounting requirements for the DVP32HP00R?

The Delta DVP32HP00R has compact dimensions of 147mm (width) x 90mm (height) x 75mm (depth), designed for efficient space utilization within control panels. It is intended for standard DIN rail mounting (35mm width), which is a common industrial standard, allowing for quick and secure installation alongside other automation components.


Proper clearance around the module for heat dissipation is important, especially in high-temperature environments or when densely packed with other devices. While it is designed for operation up to 60°C, ensuring adequate airflow will help maintain optimal performance and extend its service life.


Ensure the DIN rail is securely mounted and level, and that the module snaps firmly onto the rail. Adequate strain relief for connected wiring should also be considered to prevent mechanical stress on the terminal connections, which could otherwise lead to intermittent contact or connection failure over time.


What is the operating temperature range of the Delta DVP32HP00R module?

The Delta DVP32HP00R module operates reliably within an ambient temperature range of 0°C to 60°C (32°F to 140°F). This broad operating range makes it suitable for many industrial environments, including those with moderate heating or cooling challenges. Adhering to this range is crucial for maintaining the integrity and lifespan of the electronic components within the module.


Operating the module outside of its specified temperature range can lead to performance degradation, intermittent faults, or permanent damage. For applications operating near the upper limit of 60°C, ensure adequate ventilation and consider derating the load on the output relays if necessary, as heat generated by the loads themselves can contribute to the ambient temperature around the module.


Storage temperature specifications are also provided, typically ranging from -20°C to 70°C (-4°F to 158°F), which is important for modules that may be stored before installation or transported between sites. Always allow modules to acclimate to the operating environment's temperature before powering them up to prevent condensation issues.


How does the DVP32HP00R's high-density configuration benefit an industrial system?

The high-density design of the DVP32HP00R, offering 32 relay outputs in a single module, significantly reduces the physical footprint required in a control panel compared to using multiple lower-point modules. This space-saving aspect is crucial in modern automation where panel real estate is often at a premium, allowing for more equipment to be housed or for smaller, more cost-effective enclosures.


This density also streamlines wiring efforts. Consolidating 32 control points into one module means fewer cables, fewer terminal blocks, and less overall wiring complexity, leading to reduced installation time and lower labor costs. It also simplifies maintenance and troubleshooting, as fewer components need to be traced.


Furthermore, a high-density I/O module can lead to a more organized and aesthetically pleasing control panel layout. This improved organization not only enhances visual appeal but also contributes to better airflow and thermal management within the enclosure, potentially improving the overall reliability of the system.


What type of isolation does the DVP32HP00R provide for its outputs?

The Delta DVP32HP00R provides robust isolation for its 32 relay outputs, typically offering an isolation voltage rating of 1500VAC. This level of isolation is critical for protecting the PLC's internal circuitry from transient voltages, surges, and electrical noise originating from the connected field devices. It ensures that the control system remains stable and unaffected by the electrical environment of the actuators or loads it manages.


This electrical isolation is achieved through the physical separation provided by the relay mechanism itself. Each relay contact is electrically isolated from the PLC's logic side and from adjacent output circuits (commoning is typically done within the module for groups of outputs). This prevents ground loops and ensures that faults in one output circuit do not propagate to others or to the PLC's processor.


Proper grounding of the PLC system and the connected loads is still essential, even with inherent isolation. The 1500VAC rating signifies the module's ability to withstand high potential differences, safeguarding the system's integrity during normal operation and in the event of unexpected electrical events, contributing to overall system safety and reliability.


Does the DVP32HP00R require external power for its relay outputs?

No, the Delta DVP32HP00R's relay outputs do not require a separate external power supply for their switching function; they are controlled directly by the PLC's internal power. The module draws its operational power from the PLC's backplane or power supply unit as part of the overall DVP system. The 110-240VAC rating refers to the voltage that the relay contacts can switch, not the power needed to operate the module itself.


The internal power required by the module is typically low, around 5W, and is supplied through the PLC's communication bus or dedicated power connectors. This simplifies wiring and installation, as you only need to connect the control voltage to the PLC and the field wiring to the output terminals. The relay coils are energized by the PLC's internal power supply, facilitating the switching of the higher voltage AC or DC loads.


Therefore, when installing, ensure the PLC itself is powered correctly. The DVP32HP00R then uses this established power to drive its internal relays, allowing the contacts to open or close according to the programmed logic, thereby switching the connected external loads.


What are the shock and vibration resistance standards for the DVP32HP00R?

The Delta DVP32HP00R module is designed to meet stringent industrial standards for shock and vibration resistance, including IEC60068-2-27 (shock) and IEC60068-2-6 (vibration). These certifications indicate that the module can withstand the mechanical stresses typically encountered in industrial environments, such as those found on mobile equipment or in facilities with heavy machinery.


Compliance with IEC60068-2-27 means the module is tested to resist sudden impacts or jolts, ensuring its internal components remain secure and operational even when subjected to significant acceleration and deceleration forces for a short duration. This is critical for applications where equipment might experience unexpected movements or vibrations.


Similarly, meeting IEC60068-2-6 standards confirms the module's ability to endure continuous or resonant vibrations over a range of frequencies and amplitudes without degradation. This resilience is vital for long-term reliability in environments where constant mechanical disturbances are present, such as near large rotating machinery or on factory floors with significant activity.


How can I protect the relay contacts from arcing when switching inductive loads?

To protect the relay contacts of the DVP32HP00R from arcing when switching inductive loads (like motors or solenoids), you should employ appropriate arc suppression techniques. A common and effective method is to connect a snubber circuit, typically composed of a resistor and capacitor in series, across the load or across the relay contacts.


For DC inductive loads, a freewheeling diode (also known as a flyback diode) connected in reverse parallel across the load is highly recommended. This diode provides a path for the inductive current to dissipate safely when the relay opens, preventing a large voltage spike that can cause arcing across the contacts and damaging them. Ensure the diode is rated appropriately for the voltage and current involved.


Alternatively, using external surge suppression modules designed for relay contacts can provide robust protection. These devices absorb transient energy and limit voltage spikes. When selecting suppression methods, always consider the voltage and current characteristics of the inductive load to ensure the chosen suppression solution is adequately rated and effective.

Menu