The Delta AS-PS02 DC System Power Supply Unit stands as a robust solution for industrial power needs, offering exceptional reliability and efficiency. Its core advantages include a compact design, high power density, and advanced protection features, making it ideal for demanding automation and control applications. Key technical parameters, such as its 24VDC output voltage and 10A output current, ensure it meets the rigorous demands of modern industrial systems.
Product Specifications
| Feature | Specification |
| :------------------- | :---------------------------------- |
| Model | AS-PS02 |
| Output Voltage | 24V DC |
| Output Current | 10A |
| Input Voltage Range | 100-240V AC |
| Frequency | 50/60 Hz |
| Efficiency | >88% |
| Operating Temperature | -20°C to +70°C |
| Protection | OVP, OCP, SCP, OTP |
| Dimensions (WxHxD) | 125mm x 125mm x 130mm |
| Mounting | DIN Rail |
Core Features & Market Positioning
The Delta AS-PS02 distinguishes itself through its high efficiency and superior thermal management, crucial for extended operational life in harsh industrial environments. Its robust overload and short-circuit protection mechanisms (OCP, SCP) safeguard connected equipment, minimizing downtime and repair costs. Market positioning for the AS-PS02 centers on its reliability and cost-effectiveness, providing a dependable power foundation for various automation platforms. Delta's reputation for quality manufacturing further solidifies its standing as a preferred choice for industrial power solutions.
Key Application Scenarios
This versatile DC power supply unit is well-suited for a wide array of industrial applications, including programmable logic controller (PLC) systems, motor control drives, and various sensor and instrumentation networks. Its stable 24VDC output is fundamental for powering control panels, HMI devices, and other critical components in manufacturing lines, process automation, and building management systems. Industries such as automotive manufacturing, food and beverage processing, and material handling frequently rely on the AS-PS02 for uninterrupted system operation.
Practical System Integration Guidance
Integrating the Delta AS-PS02 into existing or new control systems is streamlined due to its standard DIN rail mounting capability. Proper wiring involves connecting the AC input terminals securely, ensuring correct polarity for the DC output, and grounding the unit for safety. While specific programming is not directly involved with the power supply itself, its stable output voltage is essential for the reliable operation of programmable devices. Users should consult the detailed manual for specific terminal assignments and recommended cable gauges to ensure optimal performance and safety during installation.
Operation and Risk Mitigation
Safe operation of the Delta AS-PS02 requires adherence to its specified input voltage and environmental operating conditions. Overvoltage protection (OVP), overcurrent protection (OCP), short-circuit protection (SCP), and over-temperature protection (OTP) are built-in to mitigate common risks. In the event of a fault, checking for proper ventilation, ensuring load does not exceed the 10A rating, and verifying input power stability are primary troubleshooting steps. Referencing the unit's status indicators, if present, or consulting the technical documentation for specific error code interpretations is recommended for efficient fault diagnosis.
Scalability & Long-Term Value
The AS-PS02 offers excellent long-term value through its robust design and compatibility with standard industrial automation components. While not directly upgradeable in terms of firmware, its scalability is achieved by deploying multiple units in parallel or series, or by selecting higher-capacity Delta power supply models as system demands grow. Its integration into modern Industrial Internet of Things (IIoT) ecosystems is facilitated by its stable power delivery, ensuring reliable communication and data acquisition from connected devices. This inherent reliability contributes to reduced total cost of ownership over the lifespan of the industrial system.
Frequently Asked Questions
What is the primary function of the Delta AS-PS02?
It provides a stable 24V DC power output for industrial automation systems. This ensures reliable operation of sensitive electronic components and control devices. Its primary goal is to convert AC mains voltage into a usable DC voltage.
The unit's robust design makes it suitable for demanding factory floor environments. It offers protection against common electrical disturbances, safeguarding connected equipment. This reliability is key for preventing costly operational disruptions.
This power supply is crucial for powering PLCs, sensors, actuators, and HMIs. Its consistent power delivery is fundamental for the smooth functioning of complex control architectures. It acts as the backbone for many automated processes.
How do I connect the Delta AS-PS02 to my system?
Connect the AC input terminals to your mains power supply. Ensure correct wiring polarity for the DC output terminals to your load. Always verify connections before applying power to prevent damage.
Ground the unit properly using the dedicated earth terminal for safety. Consult the product manual for specific wiring diagrams and recommended cable sizes. Proper grounding is essential for electrical safety and system integrity.
Double-check all connections for tightness and correct phasing. Incorrect wiring can lead to immediate component failure or safety hazards. Always follow electrical codes and best practices during installation.
What are the main protection features of the AS-PS02?
It includes Overvoltage Protection (OVP) to prevent damage from voltage spikes. Overcurrent Protection (OCP) and Short-Circuit Protection (SCP) safeguard against excessive current draws. These features protect both the power supply and connected devices.
Over-Temperature Protection (OTP) is also integrated to prevent overheating. If the internal temperature exceeds safe limits, the unit will shut down. This feature is vital for maintaining operational integrity and longevity.
These combined protections ensure a reliable and safe power source for critical industrial equipment. They minimize the risk of downtime and costly repairs due to electrical faults. This makes the AS-PS02 a dependable choice.
Can the Delta AS-PS02 be used in extreme temperatures?
The unit operates reliably within a wide temperature range of -20°C to +70°C. This broad operating window makes it suitable for diverse industrial environments, including cold storage or hot production areas. Always ensure adequate ventilation.
Exceeding the specified temperature limits can reduce efficiency and lifespan. If operating at the upper end of the range, ensure proper airflow. Consider heat dissipation in enclosed control cabinets.
For applications outside this range, alternative solutions or environmental controls may be necessary. Always refer to the product's datasheet for precise operating parameters and limitations. Consult Delta for specialized environmental requirements.
What is the typical efficiency rating of the AS-PS02?
The AS-PS02 boasts an efficiency rating typically above 88%. High efficiency means less energy is wasted as heat, leading to lower operating costs. This also contributes to a smaller environmental footprint for your operations.
This high efficiency is achieved through advanced power conversion technology. It allows for a more compact design by minimizing the need for large heat sinks. This is beneficial for space-constrained industrial panels.
Improved efficiency also translates to greater reliability, as less heat is generated internally. This is crucial for applications requiring continuous operation in demanding conditions. It supports longer component lifespan.
What kind of input voltage does the AS-PS02 accept?
It accepts a wide AC input voltage range, typically from 100V to 240V. This global compatibility simplifies deployment across different regions with varying power grids. It accommodates common single-phase AC power sources.
The unit also supports both 50Hz and 60Hz frequencies, further enhancing its versatility. This ensures seamless operation regardless of the local power frequency standard. It's designed for international industrial use.
This broad input tolerance reduces the need for external voltage converters. It simplifies inventory management and installation in multinational projects. It offers flexibility for diverse power environments.
How does Overload Protection (OCP) work on the AS-PS02?
OCP limits the output current to a safe level when the load exceeds the specified maximum. If the current draw is too high, the power supply will reduce its output or shut down to prevent damage. This protects the unit and the load.
The OCP is designed to allow for temporary current surges, such as motor startup. However, sustained overloads will trigger the protection mechanism. This ensures the power supply remains operational under normal conditions while guarding against faults.
If OCP is activated, troubleshooting the connected load is necessary to identify the cause of the excessive current. Once the overload condition is resolved, the unit typically resets automatically or requires a power cycle. Check the manual for reset procedures.
Is the Delta AS-PS02 suitable for use in hazardous locations?
The standard AS-PS02 is designed for general industrial environments. It is not inherently certified for hazardous locations (e.g., explosive atmospheres). Use in such areas requires specialized, certified equipment.
For hazardous area applications, consult Delta's product catalog for intrinsically safe or explosion-proof power supply options. Using the wrong type of equipment can create significant safety risks and regulatory non-compliance. Always verify certifications.
Ensure that any power supply used in potentially hazardous zones meets the specific ATEX, IECEx, or other regional certifications required. Compliance is critical for personnel safety and operational integrity. Specialized units are engineered with enhanced safety features.
What is the physical size and mounting method for the AS-PS02?
The AS-PS02 features a compact form factor, with dimensions typically around 125mm x 125mm x 130mm (WxHxD). This compact design is ideal for installation in space-constrained industrial enclosures. It minimizes the footprint within control panels.
It is designed for easy and secure mounting onto a standard 35mm DIN rail. This is a common mounting standard in industrial control cabinets, simplifying integration with other components. The DIN rail system ensures quick installation and removal.
This mounting method provides mechanical stability and facilitates organized wiring within the enclosure. It allows for quick replacement or addition of power supply modules as needed. The robust mounting mechanism ensures it stays secure.
How can I troubleshoot a fault with the Delta AS-PS02?
First, check that the input AC voltage is within the specified range and stable. Verify that the DC output load does not exceed the unit's 10A capacity. Ensure all wiring connections are secure and correctly polarized.
Inspect for any signs of physical damage or overheating. Check that ventilation openings are not obstructed, as poor airflow can lead to Over-Temperature Protection (OTP) activation. Review the unit's status indicators, if applicable.
Consult the Delta AS-PS02 user manual for specific troubleshooting steps and error code interpretations. If the problem persists, contact Delta technical support for further assistance. Do not attempt repairs if you are not qualified.