DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX 45kW VLT AutomationDrive FC-302 3AC 500V High Power

stars
  • Availability:In Stock
  • Brand:DANFOSS
  • Model:FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX
  • HS: 8504409999
Availability:In Stock
$6572.00
zhongpingtech

The DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX 45kW VLT AutomationDrive FC-302 3AC 500V High Power stands as a robust and intelligent variable frequency drive engineered for demanding industrial applications. This high-power unit excels in optimizing motor control, delivering significant energy savings, and enhancing process efficiency across a wide spectrum of industries. Its advanced features, including precise speed regulation, built-in harmonic mitigation, and comprehensive communication options, position it as a superior choice for sophisticated automation solutions. The drive boasts a power rating of 45 kW, operates on a 3-phase AC supply at 500V, and is designed for high-performance operation, making it ideal for applications requiring superior torque control and dynamic response.


Product Specifications


| Parameter                     | Specification                                 |

| :---------------------------- | :-------------------------------------------- |

| Model Number                  | FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX        |

| Rated Power                   | 45 kW                                         |

| Input Voltage                 | 3 AC 500V                                     |

| Series                        | VLT AutomationDrive FC-302                    |

| Enclosure Rating              | IP21/IP54 (depending on configuration)        |

| Cooling                       | Fan Cooled                                    |

| Control Method                | Advanced V/Hz, Vector Control                 |

| Protection Features           | Overload, Overvoltage, Undervoltage, Short Circuit, Ground Fault, Overheat |

| Communication Options         | Built-in slots for various fieldbuses (e.g., Profibus, EtherNet/IP, Modbus) |

| Ambient Temperature Operating | -20°C to +50°C (derating may apply)           |


Core Features & Market Positioning


The DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX distinguishes itself through its sophisticated control algorithms, offering unparalleled precision in motor speed and torque regulation, a critical advantage in processes requiring tight tolerances. Its advanced V/Hz control and optional advanced vector control capabilities ensure optimal motor performance across varying loads. The integrated harmonic mitigation features, such as built-in DC chokes and optional Active Filters, significantly reduce harmonic distortion on the power network, leading to cleaner power and compliance with stringent grid codes. This focus on power quality and energy efficiency positions the FC-302 series as a market leader for applications where operational cost reduction and environmental responsibility are paramount. Furthermore, the drive's robust construction and extensive diagnostic capabilities contribute to its reputation for reliability and long service life in demanding industrial environments.


Key Application Scenarios


This high-power 45kW VLT AutomationDrive is ideally suited for a wide array of heavy-duty industrial applications. Its precise control makes it invaluable in pump and fan applications where flow or pressure regulation is critical, leading to substantial energy savings through optimized motor speed. In the material handling sector, the drive provides the robust torque and dynamic response needed for conveyors, cranes, and elevators, ensuring smooth and efficient movement of goods. Manufacturing processes, such as extruders, mixers, and compressors, also benefit significantly from the FC-302's ability to deliver consistent performance under fluctuating load conditions. Furthermore, its suitability for high-power motor control extends to applications in water treatment, HVAC systems, and general industrial machinery, where reliability and efficiency are non-negotiable.


Practical System Integration Guidance


Integrating the DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX requires adherence to electrical safety standards and proper setup procedures. Ensure the drive is installed in a clean, dry environment with adequate ventilation, respecting the specified ambient temperature range of -20°C to +50°C, with potential derating at higher temperatures. Proper grounding of both the motor and the drive is essential to prevent electrical noise and ensure safety. For system integration, carefully plan the power wiring, connecting the 3-phase 500V AC supply to the designated terminals, and the motor to the output terminals. Utilize shielded motor cables to minimize electromagnetic interference, especially in high-frequency applications. Commissioning involves configuring essential parameters such as motor data, ramp times, and control modes (V/Hz or vector control) via the drive's control panel or software. Integrating communication modules for fieldbus integration allows seamless connection to SCADA or PLC systems, enabling remote monitoring and control.


Operation and Risk Mitigation


Safe and efficient operation of the DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX is paramount. Always ensure that all personnel involved in the installation, operation, and maintenance are adequately trained and familiar with the drive's documentation and electrical safety procedures. Before powering up, verify all connections and parameter settings to prevent damage to the drive or connected equipment. During operation, monitor for any unusual sounds or vibrations. Common fault codes, such as F01 (Overcurrent), F02 (Overvoltage), and F03 (Undervoltage), indicate specific issues that require prompt attention. For instance, an overcurrent fault might stem from an overloaded motor or incorrect motor parameters, while undervoltage could indicate a problem with the incoming power supply. Always refer to the official Danfoss VLT AutomationDrive FC-302 manual for detailed troubleshooting steps and diagnostic information.


Scalability & Long-Term Value


The DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX offers significant scalability and long-term value for industrial operations. Its modular design facilitates the addition of optional communication cards, allowing for seamless integration with various industrial networks such as Profibus, DeviceNet, or EtherNet/IP, ensuring compatibility with evolving automation architectures. This adaptability makes it easy to upgrade existing systems or incorporate the drive into new, sophisticated IIoT-enabled platforms for advanced data analytics and predictive maintenance. The drive's robust construction and Danfoss's reputation for product longevity mean it provides a reliable and cost-effective solution over its operational lifespan, minimizing the need for frequent replacements and contributing to a lower total cost of ownership.


FAQs


What are the primary benefits of using the DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX?


This drive offers substantial energy savings by precisely controlling motor speed. It enhances process efficiency through advanced motor control algorithms. The robust design ensures high reliability and a long operational lifespan.


Can this VLT AutomationDrive be used with any 45kW motor?


Yes, provided the motor is suitable for variable frequency drive operation and its voltage/frequency ratings match the drive's capabilities. Proper motor parameterization in the drive is crucial for optimal performance.


What communication protocols does the FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX support?


The drive supports various protocols via optional communication cards. Common options include Profibus DP, EtherNet/IP, Modbus TCP/IP, and DeviceNet. This allows integration into diverse automation systems.


How do I connect the DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX to my PLC?


Connection is typically achieved through optional communication modules. Install the appropriate fieldbus card in the drive and wire it according to the protocol's specifications. Then, configure the drive and PLC for communication.


What is the typical power factor of the FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX?


The drive generally maintains a high power factor close to unity, especially when operating at or near full load. This reduces reactive power demand on the supply and improves overall system efficiency.


Does the FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX include built-in braking capabilities?


Yes, this model can be configured with internal braking choppers or external braking resistors for dynamic braking applications. This is essential for applications requiring rapid deceleration or holding loads.


What are the safety features of this Danfoss VLT AutomationDrive?


It incorporates essential safety functions like overload protection, overvoltage/undervoltage monitoring, and short-circuit protection. Advanced safety options, such as Safe Torque Off (STO), can also be implemented.


How can I troubleshoot a fault code on the FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX?


Consult the VLT AutomationDrive FC-302 user manual for a detailed list of fault codes and their meanings. Common faults like overcurrent require checking motor load and parameters.


What is the maximum ambient temperature for operating the FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX?


The drive can operate in ambient temperatures from -20°C to +50°C. However, derating of the drive's output current may be necessary at temperatures above 40°C to prevent overheating.


Is the DANFOSS FC-302P45KT5E20H2XGCXXXSXXXXAXBXCXXXXDX suitable for soft-starting applications?


Absolutely. The primary function of a VFD is to provide a controlled soft start, gradually ramping up motor speed and torque. This minimizes mechanical stress and inrush current.