Siemens 5SY6363-7CC High Breaking Capacity Circuit Breaker 3P 63A

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:5SY6363-7CC
  • HS: 85362030
Availability:In Stock
$19.53
zhongpingtech

The Siemens 5SY6363-7CC is a robust 3-pole, 63A high breaking capacity circuit breaker designed for critical electrical protection in demanding industrial environments. This advanced device offers superior fault current interruption, ensuring the safety and operational continuity of electrical systems. Its core advantages lie in its high breaking capacity (Icu), reliable tripping characteristics, and compact design, making it a preferred choice for panel builders and maintenance engineers. Key technical parameters include a rated voltage of 400V AC, a tripping curve of C, and an Icn of 25kA.


Siemens 5SY6363-7CC: Product Specifications


| Feature               | Specification                                 |

| :-------------------- | :-------------------------------------------- |

| Product Type          | Miniature Circuit Breaker (MCB)               |

| Series                | 5SY6                                          |

| Number of Poles       | 3P                                            |

| Rated Current (In)    | 63A                                           |

| Rated Voltage (Ue)    | 400V AC                                       |

| Breaking Capacity (Icu) | 6 kA                                          |

| Breaking Capacity (Icn) | 25 kA                                         |

| Tripping Curve        | C                                             |

| Frequency             | 50/60 Hz                                      |

| Insulation Voltage    | 500V                                          |

| Surge Withstand       | 6 kV (1.2/50 µs)                              |

| Terminal Type         | Screw Terminal                                |

| Ambient Temperature   | -25 to +45 °C                                 |

| Protection Class      | IP20 (when installed in enclosure)            |

| Mounting Type         | DIN Rail (35mm)                               |

| Compliance Standards  | IEC 60898, IEC 60947-2                          |

| Manufacturer          | Siemens                                       |


Core Features & Market Positioning


The Siemens 5SY6363-7CC distinguishes itself through its exceptionally high breaking capacity, rated at 25kA (Icn) and 6kA (Icu), which significantly exceeds that of standard MCBs. This capability is paramount for installations where substantial fault currents are anticipated, such as in industrial plants, commercial buildings, and critical infrastructure. The Type C tripping characteristic ensures it handles inrush currents typical of inductive loads (like motors) without nuisance tripping, while still providing rapid protection against short circuits. Its robust construction and adherence to stringent IEC standards underscore Siemens' commitment to reliability and safety, positioning the 5SY6363-7CC as a premium protective device for demanding applications where dependable performance is non-negotiable.


Key Application Scenarios


This high breaking capacity circuit breaker finds its optimal use in main distribution boards, sub-distribution boards, and critical load protection circuits within industrial facilities. It is ideally suited for safeguarding motor control centers (MCCs), power distribution for heavy machinery, and areas with high fault current potential, such as near transformers or capacitor banks. In commercial settings, it provides essential protection for HVAC systems, large lighting circuits, and essential services where electrical continuity and safety are paramount. The 3-pole configuration is standard for three-phase power systems, ensuring balanced protection across all phases.


Practical System Integration Guidance


Integrating the Siemens 5SY6363-7CC into existing or new electrical panels is straightforward due to its standard DIN rail mounting and terminal design. Ensure that the upstream power supply and downstream circuits are properly sized to match the 63A rating and the breaker's voltage limits. For optimal performance and safety, it is crucial to connect the line (incoming power) to the top terminals and the load (outgoing circuits) to the bottom terminals. Proper torque must be applied to the screw terminals to ensure a secure connection, preventing overheating and potential failure. Always verify that the ambient operating temperature remains within the specified range (-25 to +45 °C) for reliable tripping performance.


Operation and Risk Mitigation


The Siemens 5SY6363-7CC operates automatically, disconnecting the circuit when fault currents exceed its rated tripping threshold, thus preventing damage to equipment and mitigating fire hazards. Its primary function is to interrupt short circuits and overload conditions swiftly. Understanding the C-curve characteristic is vital; it allows for a moderate inrush current (typically 5 to 10 times the rated current) before tripping, which is beneficial for inductive loads. However, in scenarios with very high starting currents or frequent transient overloads, a different tripping curve or device might be necessary to avoid unnecessary interruptions. Regular visual inspection for any signs of wear or damage, along with periodic testing by qualified personnel, are essential risk mitigation practices.


Scalability & Long-Term Value


While the 5SY6363-7CC itself is a fixed-rated device, its value lies in its robust protection, contributing to the long-term reliability and operational uptime of the electrical system it safeguards. Its compatibility with the broad Siemens ecosystem of industrial electrical components ensures seamless integration into larger Siemens-based power distribution solutions. For systems requiring advanced monitoring or integration with Industrial Internet of Things (IIoT) platforms, this breaker can be part of a larger system that includes intelligent power monitoring devices. The durable construction and established reputation of Siemens products ensure that this circuit breaker offers enduring protection, minimizing the need for premature replacements and contributing to a lower total cost of ownership.


Frequently Asked Questions


What is the breaking capacity of the Siemens 5SY6363-7CC?

The Siemens 5SY6363-7CC boasts a high breaking capacity, crucial for industrial safety. It features an Icn of 25kA and an Icu of 6kA. This rating ensures it can safely interrupt significant fault currents without catastrophic failure.


This high fault current interruption capability is essential in environments where short circuits can generate substantial energy. Such a rating provides a superior level of protection compared to standard domestic MCBs.


The distinction between Icn (nominal breaking capacity) and Icu (ultimate breaking capacity) is important. The 25kA Icn indicates its ability to safely break currents under normal service conditions, while the 6kA Icu specifies its performance under extreme fault conditions.


Can the Siemens 5SY6363-7CC be used for motor protection?

Yes, the 5SY6363-7CC with its Type C tripping curve is suitable for protecting circuits feeding motors. The C-curve allows for higher inrush currents typical during motor start-up.


This characteristic prevents nuisance tripping when a motor begins to operate. It strikes a balance between sensitivity to short circuits and tolerance for temporary overcurrents during motor acceleration.


However, for direct motor overload protection, an appropriately sized thermal overload relay is typically used in conjunction with the MCB. The MCB primarily provides short-circuit protection.


What is the difference between Siemens 5SY6 and 5SY4 series circuit breakers?

The Siemens 5SY6 series generally offers a higher breaking capacity compared to the 5SY4 series. This makes the 5SY6 more suitable for applications with higher potential fault currents.


The 5SY6 series is often designed for more demanding industrial environments where enhanced protection against severe electrical faults is required. This includes specific breaking capacity ratings.


While both series are reliable, the 5SY6's enhanced performance in fault current interruption makes it the preferred choice for critical infrastructure and heavy industrial installations.


How do I install the Siemens 5SY6363-7CC circuit breaker?

Installation involves mounting the 3-pole breaker onto a standard 35mm DIN rail within an appropriate enclosure. Ensure the power supply is completely isolated before commencing work.


Connect the incoming power conductors to the top terminals and the outgoing load conductors to the bottom terminals. Use appropriately sized conductors and torque them securely to prevent loose connections.


It is imperative to follow all local electrical codes and safety regulations during installation. If you are not a qualified electrician, professional installation is strongly recommended for safety and compliance.


What does the 'C' in 5SY6363-7CC refer to?

The 'C' denotes the tripping characteristic of the circuit breaker. A Type C breaker is designed to trip between 5 and 10 times its rated current (63A in this case) in case of a short circuit.


This characteristic makes it ideal for circuits with moderate inrush currents, such as those powering fluorescent lighting, solenoid coils, and small to medium-sized motors. It balances protection against short circuits with tolerance for startup surges.


Compared to Type B (trips between 3-5 times rated current), Type C offers more tolerance for inrush. Compared to Type D (trips between 10-20 times rated current), Type C is less tolerant, making it unsuitable for very high inrush loads like large transformers.


Is the Siemens 5SY6363-7CC suitable for residential use?

While it offers excellent protection, the 5SY6363-7CC is generally considered overkill for standard residential applications. Its high breaking capacity is designed for industrial and commercial environments with much higher fault current potentials.


Residential circuits typically have lower fault current levels, and standard circuit breakers (often Type B or C with lower breaking capacities) are usually sufficient and more cost-effective. Using an industrial-grade breaker in a home may not be necessary or compliant with residential electrical codes.


For residential panel upgrades or new installations, consult with a qualified electrician who can specify breakers that meet local codes and provide adequate protection for your home's specific electrical system.


What are the typical applications for a 3-pole, 63A circuit breaker like the 5SY6363-7CC?

Typical applications include main incoming protection for smaller industrial or commercial facilities, sub-distribution boards, and protecting three-phase equipment. It's common in manufacturing plants for machine tools, pumps, and HVAC systems.


This breaker is essential for safeguarding three-phase motors, transformers, and distribution lines where balanced protection across all three phases is required. Its high breaking capacity ensures it can handle fault conditions in these higher-power systems.


In essence, any three-phase electrical system requiring robust short-circuit protection up to 63A, especially where fault currents might exceed standard levels, is a prime candidate for the Siemens 5SY6363-7CC.


How does the breaking capacity (kA) affect its selection?

The breaking capacity (kA) is a critical factor determining a circuit breaker's ability to safely interrupt fault currents. Selecting a breaker with a breaking capacity equal to or greater than the maximum prospective fault current at its installation point is essential.


Installing a breaker with insufficient breaking capacity can lead to the breaker failing to interrupt the fault, potentially causing severe damage, fire, and endangering personnel. The 5SY6363-7CC's 25kA rating provides a significant margin of safety in many industrial settings.


Always consult an electrical engineer or perform a fault current calculation to determine the required breaking capacity for your specific installation point to ensure safety and compliance.


What is the operating temperature range for this circuit breaker?

The Siemens 5SY6363-7CC is designed to operate reliably within an ambient temperature range of -25°C to +45°C. Operating outside this range can affect its performance and tripping characteristics.


Temperatures above +45°C can lead to reduced current-carrying capacity and potentially impact the tripping mechanism, making it less sensitive. Conversely, extremely low temperatures might affect the mechanical components.


Ensuring adequate ventilation around the breaker within its enclosure is crucial, especially in hot environments, to maintain performance and extend its service life.


Where can I find the datasheet or manual for the Siemens 5SY6363-7CC?

Official datasheets and technical manuals for the Siemens 5SY6363-7CC can typically be found on the Siemens Industry Online Support (SIOS) portal or through authorized Siemens distributors. Searching the Siemens website with the product number is the most direct method.


These documents provide comprehensive details on specifications, installation, operation, safety instructions, and troubleshooting. They are invaluable resources for engineers, installers, and maintenance personnel working with the product.


Always refer to the official documentation provided by Siemens for the most accurate and up-to-date information regarding this specific circuit breaker model.

Menu