The DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX is a robust 1.1kW, 3A, 480V three-phase automation Variable Frequency Drive (VFD) designed for demanding industrial applications. This VFD excels in precise motor control, energy efficiency, and seamless integration into advanced automation systems, offering a compelling solution for modern manufacturing and processing environments. Its core strengths lie in its advanced control algorithms, comprehensive protection features, and user-friendly commissioning capabilities, making it a valuable asset for optimizing performance and reducing operational costs.
| Parameter | Value |
| :------------------- | :-------------------------------------- |
| Model Number | FC-360H1K1T4E20H2BXCDXXSXXXXALBX |
| Power Rating | 1.1 kW |
| Rated Current | 3 A |
| Voltage | 480 V (Three Phase) |
| Enclosure Type | ALBX |
Core Features & Market Positioning
The DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX stands out in the competitive VFD market due to its advanced control technologies, including advanced sensorless vector control for superior motor performance across a wide speed range, and integrated dynamic braking capabilities for rapid deceleration. Its robust design, featuring an ALBX enclosure, ensures reliable operation in harsh industrial environments, offering enhanced protection against dust and moisture. Danfoss's commitment to energy efficiency is evident in this model, providing significant power savings through precise speed regulation, which is a key differentiator for cost-conscious industrial operations.
Key Application Scenarios
This VFD is ideally suited for a broad spectrum of industrial applications requiring precise motor speed and torque control. Common use cases include pump and fan control in HVAC systems, where its energy-saving capabilities can yield substantial operational cost reductions. It is also highly effective in conveyor systems, mixers, extruders, and other machinery within the food and beverage, water treatment, and general manufacturing sectors that demand reliable and efficient motor management. The 480V, three-phase configuration makes it compatible with a wide range of industrial equipment found in North American and other global markets.
Practical System Integration Guidance
Integrating the DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX into an existing system is facilitated by its user-friendly interface and comprehensive documentation. For installation, ensure the VFD is mounted in a location with adequate ventilation to prevent overheating, following the recommended clearances specified in the manual. Wiring connections should be made according to the terminal diagram, paying close attention to grounding requirements for safety and optimal performance. Commissioning typically involves configuring motor parameters, setting speed references, and adjusting control settings to match the application's specific needs, often achievable through the drive's intuitive local control panel or via remote configuration tools.
Operation and Risk Mitigation
Safe operation of the DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX is paramount. Always ensure that the VFD is properly grounded and that all safety interlocks are functional before energizing the drive and motor. Disconnect power before performing any maintenance or wiring changes. Common operational issues can often be resolved by consulting the VFD's fault code list, which provides diagnostic information for troubleshooting. Key fault codes, such as overcurrent (OC), overvoltage (OV), and undervoltage (UV), typically indicate issues with the motor, power supply, or load, requiring systematic diagnosis to mitigate risks.
Scalability & Long-Term Value
The DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX offers significant long-term value through its compatibility with Danfoss's broader ecosystem of automation components and its support for industrial communication protocols like Modbus, PROFINET, and EtherNet/IP. This allows for seamless integration into supervisory control and data acquisition (SCADA) systems and industrial internet of things (IIoT) platforms, enabling advanced monitoring, control, and data analytics. The drive's modular design and robust construction contribute to its longevity, and Danfoss's commitment to ongoing firmware updates ensures that the VFD can adapt to evolving industrial standards and requirements.
Frequently Asked Questions
What are the primary advantages of the DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX?
This VFD offers superior motor control accuracy and energy efficiency. It features advanced protection mechanisms and is built for harsh industrial environments.
Its sensorless vector control ensures precise speed and torque performance. The ALBX enclosure provides robust protection against dust and moisture.
The drive enables significant operational cost reductions through optimized energy consumption. It integrates easily into existing automation systems for enhanced control.
How do I wire the DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX for a three-phase motor?
Consult the VFD's installation manual for the specific terminal layout. Connect the three-phase power supply to the main input terminals (L1, L2, L3).
Wire the three motor leads (T1, T2, T3) to the corresponding motor output terminals on the VFD. Ensure all connections are secure and properly insulated.
Proper grounding is essential; connect the ground terminal to a reliable earth ground. Follow all local electrical codes and safety guidelines during wiring.
What are common fault codes for this DANFOSS VFD and how can I troubleshoot them?
Common fault codes include Overcurrent (OC) and Overvoltage (OV). OC usually indicates a motor or cable issue, or a too-high acceleration ramp.
Undervoltage (UV) faults may point to a weak AC power supply or an issue with the DC bus. For specific codes, refer to the VFD's diagnostic menu or manual.
Troubleshooting often involves checking motor connections, verifying the power supply, adjusting parameter settings (like acceleration times), or inspecting the motor itself.
Can this VFD be used for pump and fan applications, and what are the benefits?
Yes, it is highly suitable for variable torque loads like pumps and fans. Its precise speed control significantly reduces energy consumption in these applications.
By matching motor speed to system demand, energy savings can be substantial compared to fixed-speed operation. This also reduces mechanical stress on the equipment.
The VFD allows for smooth start-up and shutdown, prolonging the lifespan of pumps and fans. It also facilitates advanced control strategies for optimized system performance.
What communication protocols does the DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX support for integration?
This VFD typically supports common industrial fieldbus protocols such as Modbus RTU/TCP. This allows for easy integration into SCADA systems.
It can also be configured to work with PROFINET or EtherNet/IP, enabling advanced networking capabilities for IIoT and Industry 4.0 applications.
Integration via these protocols allows for remote monitoring, parameter configuration, and diagnostics, enhancing overall system manageability and efficiency.
What is the power rating and voltage of the DANFOSS FC-360H1K1T4E20H2BXCDXXSXXXXALBX?
The product is rated for a 1.1 kW motor power output. This specifies the maximum continuous power the drive can deliver to the motor.
It operates on a 480V three-phase power supply. This voltage rating is standard for many industrial applications in various regions.
The drive also has a rated current of 3A, which is important for selecting appropriate wiring and circuit protection.
How does the ALBX enclosure type benefit the operation of this VFD?
The ALBX enclosure provides a robust and protective housing for the VFD. It is designed to withstand demanding industrial environments.
This enclosure offers enhanced protection against ingress of dust and moisture, contributing to increased reliability and a longer operational lifespan.
It ensures that the sensitive electronic components within the VFD are shielded from environmental contaminants and physical damage.
What are the key technical specifications for precise motor control with this VFD?
The VFD utilizes advanced sensorless vector control for accurate torque and speed regulation. This is crucial for applications requiring high dynamic performance.
It supports a wide output frequency range, allowing for precise speed adjustment of the connected motor. The 3A current rating is specific to its motor capacity.
The 1.1kW power rating and 480V input voltage define the operational envelope for compatible three-phase motors.
How can I ensure safe operation and mitigate risks when using this VFD?
Always follow the manufacturer's safety guidelines and electrical codes. Ensure proper grounding and disconnect power before maintenance.
Implement safety interlocks and emergency stop circuits to protect personnel and equipment. Regularly inspect wiring and connections for any signs of damage or wear.
Familiarize yourself with the VFD's fault codes and troubleshooting procedures to quickly address any operational anomalies and prevent potential hazards.
What options are available for expanding the functionality or connectivity of this DANFOSS VFD?
This VFD often supports optional communication modules for integration into various industrial networks. These can include protocols beyond standard Modbus.
Additional I/O expansion cards may be available to increase the number of digital and analog inputs/outputs for more complex control scenarios.
External braking resistors or other accessories can be connected to enhance performance for high inertia loads or frequent stopping applications.