SIEMENS VXF47.125 Flanged Three-Way Valve DN125 HVAC

stars
  • Availability:In Stock
  • Brand:SIEMENS
  • Model:VXF47.125
  • HS: 8481804090
Availability:In Stock
$1082.71
zhongpingtech

The SIEMENS VXF47.125 flanged three-way valve, DN125, is engineered for sophisticated HVAC control applications, offering precise flow management and robust performance. Key advantages include its high Kvs rating for efficient water flow, reliable actuation for stable system control, and durable construction suitable for demanding industrial environments. Core features encompass a flanged connection for secure installation, a DN125 nominal size for substantial flow capacity, and a three-way design enabling both mixing and diverting functions. Technical parameters highlight its suitability for a wide range of operating pressures and temperatures, ensuring versatility across diverse HVAC systems.


Product Specifications


| Feature            | Specification                                |

| :----------------- | :------------------------------------------- |

| Product Type       | Flanged Three-Way Valve                      |

| Manufacturer       | SIEMENS                                      |

| Model Number       | VXF47.125                                    |

| Nominal Size (DN)  | 125                                          |

| Connection Type    | Flanged                                      |

| Actuator Compatibility | Designed for Siemens actuators (e.g., GBC Series) |

| Material           | Typically Cast Iron or Ductile Iron (body)   |

| Pressure Rating    | PN16 (Standard)                              |

| Temperature Range  | -20 to 120 °C (or similar, depending on seal) |

| Kvs Value          | Varies based on specific model variant; high for DN125 |


Core Features & Market Positioning


The SIEMENS VXF47.125 distinguishes itself through its robust construction and precise control capabilities, making it a preferred choice for critical HVAC operations. Its flanged design ensures a leak-proof, secure connection, vital for maintaining system integrity under pressure. The DN125 size signifies a substantial flow capacity, ideal for large-scale heating and cooling systems where efficient hydronic balancing is paramount. Siemens' reputation for engineering excellence underpins the VXF47.125's market position as a reliable, long-term solution for facility managers and system integrators seeking dependable flow control. The valve's compatibility with a range of Siemens actuators allows for seamless integration into existing building automation systems, offering advanced control strategies.


Key Application Scenarios


This three-way valve excels in primary and secondary hydronic circuits within commercial buildings, including large offices, hospitals, and data centers. It is instrumental in controlling the flow of hot water for heating and chilled water for cooling, managing comfort levels and optimizing energy efficiency. In mixing applications, the VXF47.125 precisely blends return water with supply water to achieve desired temperature setpoints for terminal units like air handling units or fan coil units. Conversely, in diverting applications, it can direct flow to different circuits or bypass sections of the system, further enhancing operational flexibility and performance. Its DN125 size is particularly well-suited for main distribution lines where significant flow rates need to be managed.


Practical System Integration Guidance


Integrating the SIEMENS VXF47.125 requires careful consideration of its flanged connection and actuator pairing. Ensure the mating flange on the pipework is compatible with the valve's PN16 rating and that appropriate gaskets and bolting are used for a secure, leak-free seal. The valve is designed to accept a variety of Siemens electro-mechanical or electronic actuators, which should be selected based on the required torque, stroke length, and control signal (e.g., 0-10V, 4-20mA, or bus communication). Proper alignment during installation is critical to prevent undue stress on the valve body and actuator stem. Commissioning involves verifying actuator movement, checking for leaks, and calibrating the control signal to ensure accurate positioning across the valve's operating range. Refer to the specific actuator's technical documentation for detailed wiring diagrams and control parameter settings.


Operation and Risk Mitigation


Safe and efficient operation of the SIEMENS VXF47.125 relies on adherence to system design parameters and regular maintenance. The valve is designed for closed-loop hydronic systems; operating it with abrasive fluids or in environments exceeding its temperature or pressure limits can lead to premature failure. Potential issues include actuator failure, which can be identified by a lack of response or incorrect valve positioning, and seat leakage, often characterized by unintended flow when the valve is in its closed position. Regular inspection of the valve and actuator for any signs of wear, corrosion, or damage is recommended. Ensure that control system alarms are configured to detect abnormal flow or temperature conditions that might indicate a valve malfunction, allowing for prompt intervention.


Scalability & Long-Term Value


The SIEMENS VXF47.125 offers significant long-term value due to its inherent durability and compatibility with Siemens' broader building automation ecosystem. Its robust construction minimizes the need for frequent replacement, contributing to lower total cost of ownership. As HVAC control strategies evolve, the valve can be readily integrated with newer, more sophisticated Siemens actuators and controllers, including those supporting digital communication protocols and IIoT functionalities. This ensures that facility managers can upgrade their control capabilities without necessarily replacing core hydronic components, safeguarding their investment and adapting to future demands for energy efficiency and smart building management.


---


Frequently Asked Questions (FAQs)


What is the maximum working pressure for the SIEMENS VXF47.125?


The SIEMENS VXF47.125 typically operates with a PN16 pressure rating. This signifies a maximum allowable operating pressure of 16 bar at ambient temperatures. Ensure your system's design pressure remains within this specification for safe and reliable operation.


This rating is crucial for preventing valve body damage and ensuring system integrity over its lifespan. Always consult the specific product datasheet for the exact pressure rating.


Exceeding the PN16 limit can lead to catastrophic failure, posing significant safety risks and system downtime. Proper system design and pressure regulation are therefore essential.


How do I select the correct actuator for the SIEMENS VXF47.125?


Actuator selection depends on torque requirements, stroke length, and control signal type. The VXF47.125 DN125 requires an actuator with sufficient torque to overcome system pressure and friction.


Consider the valve's nominal size (DN125) and typical system pressures to determine the necessary torque output. Also, match the actuator's stroke to the valve's travel needs for full closure and opening.


Ensure the actuator's control input (e.g., 0-10V, 4-20mA, bus communication) is compatible with your building automation system for seamless integration and precise control.


What are common applications for a three-way valve like the SIEMENS VXF47.125 in HVAC?


Three-way valves are commonly used for mixing hot and cold water streams to achieve desired temperatures. They are vital in HVAC for controlling the flow to air handling units or fan coil units.


They also function in diverting flow, directing it through different heating or cooling circuits or bypassing certain sections. This flexibility is key for efficient zone control and system balancing.


In large commercial HVAC systems, the DN125 size of the VXF47.125 indicates its use in main hydronic distribution lines, managing substantial water flow for primary and secondary loops.

Menu