The ABB S201-B16 is a 16A, single-pole miniature circuit breaker (MCB) designed for reliable protection of electrical circuits in residential, commercial, and industrial applications. This current-limiting device from the System pro M compact® S200 series offers effective overload and short-circuit protection. Its B-characteristic tripping curve makes it suitable for circuits with moderate inrush currents, commonly found in household appliances and lighting circuits.


Product Specifications


| Feature                      | Value                                     |

| ---------------------------- | ----------------------------------------- |

| Rated Current (In)           | 16 A                                      |

| Number of Poles              | 1                                         |

| Tripping Characteristic      | B                                         |

| Rated Voltage (IEC 60898-1) | 230/400 V AC                             |

| Rated Voltage (IEC 60947-2) | 230 V AC                                  |

| Breaking Capacity (IEC 60898) | 6 kA                                      |

| Breaking Capacity (IEC 60947-2) | 10 kA                                     |

| Rated Insulation Voltage (Ui) | 440 V AC                                  |

| Impulse Withstand Voltage (Uimp) | 4 kV (5 kV at 2000m, 6.2 kV at sea level) |

| Frequency                    | 50/60 Hz                                  |

| Energy Limiting Class        | 3                                         |

| Pollution Degree             | 3                                         |

| Mounting                     | DIN Rail                                  |

| Terminal Capacity            | 0.75 - 35 mm²                             |

| Standards Compliance         | IEC/EN 60898-1, IEC/EN 60947-2, UL1077   |


Core Features & Market Positioning


The ABB S201-B16 stands out due to its combination of reliable performance and ease of installation. Its current limiting design quickly interrupts fault currents, minimizing damage to downstream equipment. The device features a patented connection terminal with a pressure plate, allowing for easy and secure wiring with conductors up to 35 mm². Its compact design, with a width of only one module (17.5mm), saves valuable space in electrical panels. The S201-B16 is suitable for use with or without additional accessories such as auxiliary switches.


Key Application Scenarios


This ABB 16A circuit breaker is commonly used for protecting lighting circuits and socket outlets in residential buildings. It is also suitable for protecting individual appliances with moderate starting currents, such as refrigerators or washing machines. In commercial settings, the S201-B16 can be used for protecting branch circuits supplying office equipment and lighting. Industrial applications include protection of control circuits and small machinery.


Practical System Integration Guidance


The ABB S201-B16 is designed for easy installation on standard DIN rails. It can be fed from either direction. The optimized quick fastening allows easy removal and insertion of the devices when combined with the System pro M compact busbar system. The connection opening for conductors is located above the connection opening for the busbar to improve visibility during wiring. The S201-B16 can be combined with auxiliary contacts, shunt trips, and undervoltage releases for enhanced functionality.


Operation and Risk Mitigation


The S201-B16 provides reliable protection against overloads and short circuits. In case of an overload, the thermal tripping mechanism will activate, disconnecting the circuit after a certain time. In the event of a short circuit, the electromechanical tripping mechanism will immediately interrupt the circuit. The red ON / green OFF indicator provides a clear visual indication of the switch position. The device has an IP20 degree of protection, protecting against contact with live parts and solid objects larger than 12mm.


Concluding Section (FAQs)


Q1: What is the breaking capacity of the ABB S201-B16?


The S201-B16 has a breaking capacity of 6 kA according to IEC/EN 60898-1. This refers to its ability to safely interrupt a short-circuit current. It also has a 10kA breaking capacity according to IEC/EN 60947-2.


The 6kA rating is sufficient for most residential and commercial applications. Higher breaking capacities may be required in industrial settings.


This ensures safe operation and prevents damage to the circuit breaker itself.


Q2: What does the B-characteristic mean?


A B-characteristic circuit breaker trips at 3 to 5 times its rated current. This makes it suitable for resistive and slightly inductive loads.


Examples include lighting and household appliances. It avoids nuisance tripping due to small current surges.


B-curve MCBs are a common choice for general circuit protection.


Q3: What type of wiring can be used with this circuit breaker?


The ABB S201-B16 accepts a wide range of wire sizes. It can accommodate solid, stranded, and flexible wires.


The terminal capacity ranges from 0.75 to 35 mm². This allows for connection of various conductor sizes.


Using the correct wire size ensures a safe and reliable connection.


Q4: Is the ABB S201-B16 suitable for industrial use?


Yes, the S201-B16 can be used in industrial applications. It is compliant with IEC/EN 60947-2 and UL1077 standards.


It can protect control circuits and small machinery. However, check the specific requirements of the application.


Consider the breaking capacity and the tripping characteristics required.


Q5: What is the lifespan of the ABB S201-B16?


The S201-B16 is designed for a long operational life. ABB products are known for their durability and reliability.


The exact lifespan depends on the operating conditions. This includes load and ambient temperature.


Regular inspection and maintenance can help extend the lifespan.


Q6: Can auxiliary contacts be added to the S201-B16?


Yes, auxiliary contacts can be added to the ABB S201-B16. These provide additional functionality and monitoring capabilities.


Bottom-fitting auxiliary contacts can be mounted. This saves space in the electrical panel.


Auxiliary contacts can indicate the breaker's status remotely.


Q7: What standards does the ABB S201-B16 comply with?


The ABB S201-B16 complies with several international standards. These include IEC/EN 60898-1, IEC/EN 60947-2, and UL1077.


These standards ensure the safety and performance of the device. Compliance allows for use in various regions and applications.


The device also meets DIN VDE 0641-11 requirements.


Q8: What is the insulation voltage of this circuit breaker?


The rated insulation voltage (Ui) of the S201-B16 is 440V AC. This refers to the voltage the device can withstand continuously.


It ensures safe isolation between the conductive parts and the environment.


The impulse withstand voltage (Uimp) is 4kV.


Q9: What is the operating temperature range of the S201-B16?


The operating temperature range is typically -25 to +55°C. This allows for use in a variety of environments.


Extreme temperatures can affect the performance. Consider derating the current if necessary.


Ensure adequate ventilation to prevent overheating.


Q10: Where can I find the ABB S201-B16 datasheet?


The datasheet can be found on the ABB website. Search for the product using the part number 2CDS251001R1165.


Datasheets provide detailed technical information. This includes specifications, wiring diagrams, and performance curves.


Always refer to the official datasheet for accurate information.


Menu